DOWNLOAD Sony DSC-P8 (serv.man4) Service Manual ↓ Size: 426.24 KB | Pages: 37 in PDF or view online for FREE

Model
DSC-P8 (serv.man4)
Pages
37
Size
426.24 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-p8-sm4.pdf
Date

Sony DSC-P8 (serv.man4) Service Manual ▷ View online

DSC-P8
6-15
1.
Flange Back Adjustment
(Using the minipattern box)
The flange back of inner focus lens is adjusted automatically. If
shifted, the auto focus is disordered.
Mode
CAMER
Subject
Siemens star chart with ND filter
for minipattern box (Note 1)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Adjustment Page
6F
Adjustment Address
18 to 3E, 40 to 53
Specified value 1
00
Specified value 2
0A to 40
Note 1:
Dark Siemens star chart.
Note 2:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin.
Caution:
If the video lens or SY-83 board was replaced, make a setting
by referring to “Precaution on Replacing the Video Lens or the
SY-83 Board” and then perform the adjustment.
Preparations before adjustments:
1) The minipattern box is installed as shown in the following fig-
ure.
Note 3:
The attachment lenses are not used.
Note 4:
Take care not to hit the mini-pattern box when ex-
tending the lens.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage 
± 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the mini-
pattern box.
Minipattern box
Below 3 cm
Camera
Camera 
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
 0.01 Vdc
Output current : more than 3.5 A
Fig. 6-1-13
Adjusting method:
Order Page Address
Data
Procedure
1
Perfom “Data setting
during camera sysem
adjustment”.
(Refer to page 6-13)
2
60
01
13 
[Write]
3
60
01
27  
[Write]
(Note 5)
4
60
02
[Read]
Check the data changes
to “01”.
5
6F
3E
[Read]
Check that the data
satisfied the specified
value 1.
6
6F
24
[Read]
Check that the data
satisfied the specified
value 2.
7
60
01
00 
[Write]
8
60
01
25 
[Write]
9
Wait for 3 seconds.
Note 5:
 The adjustment data will be automatically input to page:
6F, address: 18 to 3E and 40 to 53.
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
60
01
00 
[Write]
2
Perform “Flange Back
Check “.
[Precaution on Replacing the Video Lens or the SY-83
Board]
The DSC-P8 uses the position sensor to detect the zoom position.
Accordingly, the zoom position will vary if the position data
changes due to the replacement of the video lens or the SY-83
board, thus causing the video lens to collide against the mecha-
nism end when the power is turned off.
Though the position data is calibrated at the “Flange Back Adjust-
ment”, add the following work when making an adjustment at the
replacement of video lens to prevent a collision of video lens.
When Replacing the Video Lens
1) With current video lens assembled, turn the power on, and set
the data of page: 6F, address: 3E to “FF”, then turn the power
off.
2) Replace the video lens with a new one, turn the power on, and
perform the “Flange Back Adjustment”.
Thus, new position data will be written.
When Replacing the SY-83 Board
1) Replace the SY-83 board with a new one, set the mode dial to
“PLAY”, turn the power on, and set the data of page: 6F,
address:3E to “FF”, then turn the power off.
2) Set the mode dial to “CAMERA”, turn the power on, and per-
form the “Flange Back Adjustment”.
Thus, new position data will be written.
DSC-P8
6-16
2.
Flange Back Check
Mode
CAMERA
Subject
Siemens star
(1.0 m from the front of the lens)
(Luminance: 200 to 400 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Specified value
Focused at the TELE end and
WIDE end
Checking method:
Order Page Address
Data
Procedure
1
“Flange Back Adjust-
ment” is completed.
2
Place the Siemens star
1.0 from the front of the
lens.
3
To open the IRIS,
decrease the luminous
intensity to the Siemens
star up to a point before
noise appear on the
image.
4
60
8C
30 
[Set]
5
5F
3D
50 
[Set]
(Note 1)
6
7B
98
94 
[Set]
7
Set the zoom lens to the
TELE end then set the
center of the Siemens
star chart in the center of
the TV monitor.
8
Check that the lens is
focused.
9
60
2C
01 
[Set]
10
While observe the TV
monitor, change the
zoom to the WIDE end
and check that the lens is
focused.
Note 1:
How to find the data
Decrease the data of page: 5F, address: 3D until four sides
of a black frame can be seen on the monitor, then find
the value. The largest value under this condition will be
the seting value. If the value is less than 50, change
monitorrs.
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
5F
3D
[Read]
2
60
8C
00 
[Set]
3
7B
98
[Read]
4
Release “Data setting
during camera system
adjustment”
(Refer to page 6-13)
3.
F No. Compensation
Compensate the unevenness of the iris meter sensitivity.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Data of page: 6F, address: 6B
Adjustment Page
6F
Adjustment Address
60 to 64, 6B to 6D
Specified value
00
Note 1:
 Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin.
Adjusting methd:
Order Page Address
Data
Procedure
1
Perfom “Data setting
during camera sysem
adjustment”.
(Refer to page 6-13)
2
Perfom “Picture frame
setting”
(Refer to page 6-14)
3
60
01
BB 
[Write]
(Note 2)
4
60
02
[Read]
Check the data changes
to “01”.
5
6F
6B
[Read]
Check that the data
satisfied the specified
value.
Note 2:
 The adjustment data will be automatically input to page:
6F, address: 60 to 64 and 6B to 6D.
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
60
01
00 
[Write]
2
Release “Data settig
during camera system
adjustment”
(Refer to page 6-13)
DSC-P8
6-17
5. Light Value Adjustment
Adjust the standar light value.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Data of page: 10, address: 0C and
0D (2byte data) (Note 2)
Data of page: 6F, address: 65
Adjustment Page
6F
Adjustment Address
65 to 67
Specified value 1
0FE0 to 1020
Specified value 2
30 to 44
Note 1:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin.
Note 2:
2byte data is upper 1byte data and lower 1 byte data.
                XX XX
                                     Lower 1byte data (Page: 10, adderss: 0D)
Upper 1byte data (Page: 10, adderss: 0C)
Adjusting method:
Order Page Address
Data
Procedure
1
Perfom “Data setting
during camera sysem
adjustment”.
(Refer to page 6-13)
2
Perfom “Picture frame
setting”
(Refer to page 6-14)
3
60
01
0D 
[Write]
(Note 3)
4
60
02
[Read]
Check the data changes
to “01”.
5
10
0C
[Read]
Read the data
(Upper 1byte).
6
10
0D
[Read]
Read the data
(Lower 1byte).
7
Check that the 2byte
data (Note 2) satisfied
the specified value 1.
8
6F
65
[Read]
Check that the data
satisfied the specified
value 2.
Note 3:
The adjustment data will be automatically input to page:
6F, address: 65 to 67.
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
60
01
00 
[Write]
2
Release “Data settig
during camera system
adjustment”
(Refer to page 6-13)
4.
Mechanical Shutter Adjustment
Adjust the period which the mechanical shutter is closed, and com-
pensate the exposure.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Data of page: 6F, address: 6B
Adjustment Page
6F
Adjustment Address
6B to 6D, B8 to D7
Specified value
00
Note 1:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin.
Adjusting method:
Order Page Address
Data
Procedure
1
Perfom “Data setting
during camera sysem
adjustment”.
(Refer to page 6-13)
2
Perfom “Picture frame
setting”
(Refer to page 6-14)
3
60
01
AD 
[Write]
(Note 2)
4
60
02
[Read]
Check the data changes
to “01”.
5
6F
6B
[Read]
Check that the data
satisfied the specified
value.
Note 2:
The adjustment data will be automatically input to page:
6F, address: 6B to 6D and 8B to D7.
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
60
01
00 
[Write]
2
Release “Data settig
during camera system
adjustment”
(Refer to page 6-13)
DSC-P8
6-18
6.
Mixed Color Cancel Adjustment
Correct the dispersion of Gr/Gb filter on CCD imager
Mode
CAMERA
Subject
Color bar chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
6F
Adjustment Address
6E and 6F
Specified value
00
Note 1:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin.
Adjusting method:
Order Page Address
Data
Procedure
1
Perfom “Data setting
during camera sysem
adjustment”.
(Refer to page 6-13)
2
Perfom “Picture frame
setting”
(Refer to page 6-14)
3
6F
B5
FF 
[Write]
4
60
01
D7 
[Write]
5
Wait for 3 seconds.
6
60
01
D5 
[Write]
(Note 2)
7
60
02
[Read]
Check the data changes
to “01”.
8
6F
B5
[Read]
Check that the data
satisfied the specified
value.
Note 2:
The adjustment data will be automatically input to page:
6F, address: 6E and 6F
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
60
01
00 
[Write]
2
Release “Data settig
during camera system
adjustment”
(Refer to page 6-13)
7.
AWB 3200K Standard Data Input
Adjust the white balance reference at 3200K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
6F
Adjustment Address
70 to 87, B0, B2, and B4
Specified value
00
Note 1:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin.
Adjusting method:
Order Page Address
Data
Procedure
1
Perfom “Data setting
during camera sysem
adjustment”.
(Refer to page 6-13)
2
Perfom “Picture frame
setting”
(Refer to page 6-14)
3
6F
B5
FF 
[Write]
4
60
01
0B 
[Write]
(Note 2)
5
60
02
[Read]
Check the data changes
to “01”.
6
6F
B5
[Read]
Check that the data
satisfied the specified
value.
Note 2:
The adjustment data will be automatically input to page:
6F, address: 70 to 87, B0, B2 and B4.
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
60
01
00 
[Write]
2
Release “Data settig
during camera system
adjustment”
(Refer to page 6-13)
Page of 37
Display