DOWNLOAD Sony DSC-P8 (serv.man4) Service Manual ↓ Size: 426.24 KB | Pages: 37 in PDF or view online for FREE

Model
DSC-P8 (serv.man4)
Pages
37
Size
426.24 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-p8-sm4.pdf
Date

Sony DSC-P8 (serv.man4) Service Manual ▷ View online

DSC-P8
6-31
COVER
COVER
6-2. SERVICE MODE
2-1.
APPLICATION FOR ADJUSTMENT (SEUS)
The application for adjustment (SEUS) is used to change the coef-
ficient for calculating the signal processing or EVR data. The SEUS
performs two-way communication between PC and set through
the USB terminal. The two-way communication result data can be
written to the nonvolatile memory.
2-1-1.
Using Method of SEUS
1.
Connection
1) Connect the HASP key to the USB terminal of the PC.
2) Connect the PC and set with the USB cable.
3) Confirm that the set starts in the USB mode.
4) Start the SEUS on the PC.
5) Click 
[Connect]
 on the SEUS screen. If the connection is nor-
mal, the SEUS screen will be as shown in Fig. 6-2-1, indicat-
ing the
 
“connected”
 
state.
Note:
The SEUS will go in
 
“disconnect" state, if the set is
turned off (for instance, by resetting the set). In such a
case, click 
[Connect]
 on the SEUS screen to restore
the
 
“connected”
 
state.
2.
Operation
• Page change
To change the page, click 
[Page]
 on the SEUS screen and enter
the page to be changed. The page is displayed in hexadecimal
notation.
• Address change
To change the address, click 
[Address]
 on the SEUS screen and
enter the address to be changed. The address is displayed in
hexadecimal notation.
• Data change
To change the data, click 
[Set]
 on the SEUS screen and enter
the data. The data is displayed in hexadecimal notation.
This operation does not write the data to the nonvolatile memory.
• Data writing
To write the data to the nonvolatile memory, click 
[Write]
 on
the SEUS screen and enter the data to be written.
• Data reading
The data displayed on the SEUS screen are the data values at
the time when the pages and addresses were set, and they are
not updated automatically. To check the data change, click
[Read]
 on the SEUS screen and update the displayed data.
2-1-2.
Precaution on Use of SEUS
Wrong SEUS operation could clear correct adjustment data. To
prevent the data clear by mistake, it is recommended to save all
adjustment data by clicking 
[Page Edit]
 on the SEUS screen be-
fore starting the adjustment.
Fig. 6-2-1
DSC-P8
6-32
COVER
COVER
2-2.
DATA PROCESS
In some adjustment items, the calculation of SEUS displayed data
(hexadecimal) is needed to check the specified data or to acquire
the adjustment data. In such a case, prepare a computer capable of
calculating hexadecimal numbers.
Also, the data at two addresses are read, which are treated as 2
bytes of upper 1 byte and lower 1 byte (4-digit hex. number), to
check the specified data.
XX XX
Displayed data at lower 1 byte address
Displayed data at upper 1 byte address
2-3.
SERVICE MODE
1.
Setting the Test Mode
Page 2F
Address 21
Data
Function
00
Normal
01
Forced MOVIE mode
02
Forced SCN mode
03
Forced CAMERA PROGRAM mode
04
Forced CAMERA mode
08
Forced PLAY mode
09
Forced SET UP mode
• Before setting the data, select page: 00, address: 01, and set
data: 01.
• In the case of page 2F, writing the data by clicking 
[Write]
 on
the SEUS screen causes the data to be written to the nonvolatile
memory. In this case, the Test mode is not released even if the
set is turned off, thus requiring extreme care.
• After the adjustment/repair finished, be sure to return the data
to “00” to restore the Normal mode. Also, select page: 00, ad-
dress: 01, and set data: 00.
DSC-P8
6-33
2.
Bit Value Discrimination
In the following items, the bit values must be discriminated from
the data displayed on the SEUS. Whether bit values are “1” or “0”
can be discriminated from the table shown below.
Data displayed on SEUS
0 0
bit 3 to bit 0 discriminated
bit 7 to bit 4 discriminated
Bit values
Display on the
bit3
bit2
bit1
bit0
SEUS
or
or
or
or
bit7
bit6
bit5
bit4
0
0
0
0
0
1
0
0
0
1
2
0
0
1
0
3
0
0
1
1
4
0
1
0
0
5
0
1
0
1
6
0
1
1
0
7
0
1
1
1
8
1
0
0
0
9
1
0
0
1
A
1
0
1
0
B
1
0
1
1
C
1
1
0
0
D
1
1
0
1
E
1
1
1
0
F
1
1
1
1
B
A
Example: If the displayed data is “8E”, bit 7 - bit 4 values can be
discriminated from block (A), and also bit 3 - bit 0 val-
ues from block (B).
3.
Mode Dial Check
Page 20
Address 23
Data
Function
01
SCN
02
CAMERA PROGRAM
03
CAMERA
07
PLAY
00
MOVIE
08
SET UP
Using method:
1) Select page: 20, address: 23.
2) By discriminating the value of dispalyed data, the state of the
mode dial can be discriminated.
4.
Switch Check (1)
Page 20
Address 80
Bit
Function
When bit value=1 When bit value=0
0
POWER SW
OFF
ON
(CONTROL
SWITCH BLOCK)
1
2
3
Shutter button
OFF
ON
(XSHTR ON)
(CONTROL SWITCH
BLOCK)
4
Shutter button
OFF
ON
(XAE LOCK ON)
(CONTROL SWITCH
BLOCK)
5
MEMORY STICK
IN
OUT
IN SW
(MS-130 Board
(MS Socket))
Using method:
1) Select page: 20, address: 80.
2) By discriminating the bit value of dispaly data, the state of the
switches can be discriminated.
DSC-P8
6-34
5. Switch Check (2)
Page 20
Addresses 91, 92, 94
Using method:
1) Select page: 20, addresses: 91, 92 and 94.
2) By discriminating the dispaly data, the pressed key can be
discriminated.
Address
Data
00 to 0C
0D to 27
28 to 48
49 to 73
74 to A5
A6 to DC
DD to FF
91
CONTROL DOWN
CONTROL UP
MENU
IMAGE SIZE/
(KEY AD0)
(SELFTIMER)
(STROBO)
(SW-386 board)
DELETE
No key input
(IC402 tg)
(SW-386 board) (SW-386 board)
(S003)
(SW-386 board)
(S008)
(S004)
(S010)
92
CONTROL RIGHT CONTROL LEFT
CONTROL SET
DISPLAY/LCD
(KEY AD1)
(MACRO)
(REVIEW)
(SW-386 board)
ON/OFF
No key input
(IC402 th)
(SW-386 board) (SW-386 board)
(S006)
(SW-386 board)
(S007)
(S005)
(S009)
94
ZOOM (W)
ZOOM (T)
(KEY AD3)
(SW-386 board) (SW-386 board)
No key input
(IC402 tk)
(S001)
(S002)
6. LED Check
Using method:
1)
Select page: 20, address: 04, set data: 02.
2)
Check that all LED (STROB/CHG, POWER, SELF TIMER/
REC, AF ILLUMINATOR, AE/AF LOCK, MS ACCESS) are
lit.
3)
Select page: 20, address: 04, set data: 00.
Page 20
Address 04
Data 02
Display Code
  C:32:ss
  C:13:ss
Countermeasure
Turn the power off and on again.
Format the “Memory stick”.
Insert a new “Memory Stick”.
Cause
Trouble with hardware.
Unformatted memory stick is inserted.
Memory stick is broken.
Caution Display During Error
SYSTEM ERROR
FORMAT ERROR
MEMORY STICK ERROR
8. Self Diagnosis Code
  E:61:ss
  E:91:ss
Checking of lens drive circuit.
When failed in the focus and zoom
initialization.
Abnormality when flash is being
charged.
Checking of flash unit or replacement
of flash unit.
7. LCD & Back Light Bright Check
Page 40
Addresses DB and DC
Address
Data
Function
02
Check that LCD brightness is "Dark".
DB
12
Check that LCD brightness is "Normal".
22
Check that LCD brightness is "Bright".
DC
00
Check that Back Light brightness is "Normal".
08
Check that Back Light brightness is "Bright".
Page of 37