5-20
7.
Mechanical Shutter Adjustment
Adjust the period which the mechanical shutter is closed, and com-
pensate the exposure.
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame with the zoom lens at WIDE
end)
Adjustment Page
F
Adjustment Address
5A, 6C to 7F, D4 to D8
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
YL
(Note 2)
7
6
93
YH
(Note 2)
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to “01”.
10
6
01
00
Press PAUSE button.
11
6
01
AD
Press PAUSE button. (Note 3)
12
6
02
Check the data changes to “01”.
13
6
AB
Check the data changes to “00”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 5A, 6C to 7F and D4 to D8.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
92
00
4
6
93
00
5
Release the data setting
performed at step 2 . (Refer
to page 5-14)
6
0
01
00
6.
F No. Standard Data Input
Compensate the unevenness of the iris meter sensitivity.
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame with the zoom lens at WIDE
end)
Adjustment Page
F
Adjustment Address
29 to 2D
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
YL
(Note 2)
7
6
93
YH
(Note 2)
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to “01”.
10
6
01
00
Press PAUSE button.
11
6
01
BB
Press PAUSE button. (Note 3)
12
6
02
Check the data changes to “01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 29 to 2D.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
92
00
4
6
93
00
5
Release the data setting
performed at step 2. (Refer to
page 5-14)
6
0
01
00
5-21
8.
Light Level Adjustment
Adjust the standard LV value.
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame with the zoom lens at
WIDE end)
Measurement Point
Displayed data of page: 1 (Note 3)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
26 to 28
Specified Value
AE level: 0FE0 to 1020
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of the unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Note 3:
The right 4 digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
 
Displayed data
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
YL
(Note 2)
7
6
93
YH
(Note 2)
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to “01”.
10
6
01
00
Press PAUSE button.
11
6
01
0D
Press PAUSE button. (Note 4)
12
6
02
Check the data changes to “01”.
13
0
03
06
14
1
Check that the displayed data
(Note 3) satisfies the AE
level specified value.
Note 4:
The adjustment data will be automatically input to page:
F, address: 26 and 28.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
6
01
00
Press PAUSE button.
3
6
2C
00
4
6
92
00
5
6
93
00
6
Release the data setting
performed at step 2 . (Refer
to page 5-14)
7
0
01
00
9.
Mixed Color Cancel Adjustment
To perform mixed color cancel adjustment based on data of each
color in color bar.
Mode
CAMERA
Subject
Color bar chart
(Color reproduction adjustment
frame with the zoom lens at
WIDE end)
Adjustment Page
F
Adjustment Address
A0 to A3
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of the unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
YL
(Note 2)
7
6
93
YH
(Note 2)
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to “01”.
10
6
01
00
Press PAUSE button.
11
6
01
D7
Press PAUSE button.
12
6
01
D5
Press PAUSE button. (Note 3)
13
6
02
Check the data changes to “01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: A0 to A3.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
92
00
4
6
93
00
5
Release the data setting
performed at step 2 . (Refer
to page 5-14)
6
0
01
00
5-22
10. Auto White Balance Standard Data Input
Adjust the white balance standard data at 3200K.
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame with the zoom lens at
WIDE end)
Adjustment Page
F
Adjustment Address
3A to 3D, 59
Note 1:
 Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Note 3:
“Auto White Balance Standard Data Input” is available
only once after the power is turned on. Turn the power
off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
YL
(Note 2)
7
6
93
YH
(Note 2)
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to “01”.
10
6
01
00
Press PAUSE button.
11
6
01
11
Press PAUSE button.
12
6
01
0B
Press PAUSE button. (Note 4)
13
6
02
Check the data changes to “01”.
Note 4:
The adjustment data will be automatically input to page:
F, address: 3A to 3D and 59.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
92
00
4
6
93
00
5
Release the data setting
performed at step 2 . (Refer
to page 5-14)
6
0
01
00
5-23
Order Page Address Data
Procedure
15
6
01
A5
Press PAUSE button. (Note 6)
16
6
02
Check the data changes to “01”.
17
6
01
3F
Press PAUSE button.
18
0
03
04
19
1
Check that the displayed data
(Note 3) satisfies the R ratio
specified value.
20
0
03
05
21
1
Check that the displayed data
(Note 3) satisfies the B ratio
specified value.
Note 5:
TYPE P30 / TYPE P50
Note 6:
The adjustment data will be automatically input to page:
F, address: 3A, 40, 80, A9 and AA.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
6
01
00
Press PAUSE button.
3
6
2C
00
4
6
92
00
5
6
93
00
6
F
49
Set the data noted down at
4A
step 13, and press PAUSE
4B
button.
4C
7
Release the data setting
performed at step 3 . (Refer
to page 5-14)
8
0
01
00
9
Remove the C14 filter on the
lens.
11. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility
will be poor.
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame with the zoom lens at
WIDE end)
Filter
Filter C14 for color temperature
correction
Measurement Point
Displayed data of page: 1 (Note 3)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
3F, 40, 80, A9, AA
Specified Value
P30:
R ratio: 25C0 to 2700
B ratio: 6110 to 6250
P50:
R ratio: 2610 to 2750
B ratio: 60F0 to 6230
Note 1:
 Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Note 3:
The right 4 digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Note 4:
 “Auto White Balance Adjustment” is available only once
after the power is turned on. Turn the power off, then on
again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter on the lens.
2
0
01
01
3
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
4
6
2C
01
5
6
90
00
6
6
91
00
7
6
92
YL
(Note 2)
8
6
93
YH
(Note 2)
9
6
01
79
Press PAUSE button.
10
6
07
Check the data changes to “01”.
11
6
01
00
Press PAUSE button.
12
6
01
A7
Press PAUSE button.
13
F
49
Note down the data.
4A
4B
4C
14
F
49
26
Press PAUSE button. (Note 5)
4A
60/B0
4B
61
4C
B0/90