DOWNLOAD Sony DSC-P30 / DSC-P50 (serv.man2) Service Manual ↓ Size: 5.85 MB | Pages: 101 in PDF or view online for FREE

Model
DSC-P30 DSC-P50 (serv.man2)
Pages
101
Size
5.85 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / LEVEL 2
File
dsc-p30-dsc-p50-sm2.pdf
Date

Sony DSC-P30 / DSC-P50 (serv.man2) Service Manual ▷ View online

5-12
Address
Initial value
Remark
00 to 5F
Fixed data-1 (Initialized data)
60
0F
61
FF
62
0F
63
FF
64
0F
65
FF
66
0F
67
FF
68
0F
69
FF
6A
0F
6B
FF
6C
0F
6D
FF
6E
0F
6F
FF
70
0F
71
FF
72
0F
73
FF
74
0F
CCD black defect compensation
75
FF
76
0F
77
FF
78
0F
79
FF
7A
0F
7B
FF
7C
0F
7D
FF
7E
0F
7F
FF
80
0F
81
FF
82
0F
83
FF
84
0F
85
FF
86
0F
87
FF
88
0F
89
FF
8A
0F
8B
FF
CCD white defect compensation
8C
0F
8D
FF
6.
7 Page Table
Note 1:
Fixed data-1: Initialized data. (Refer to “1. Initializing B, E, F, 7, 9 Page Data”)
Note 2:
Fixed data-2: Modified data. (Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address
Initial value
Remark
8E
0F
8F
FF
90
0F
91
FF
92
0F
93
FF
94
0F
95
FF
96
0F
97
FF
98
0F
CCD white defect compensation
99
FF
9A
0F
9B
FF
9C
0F
9D
FF
9E
0F
9F
FF
A0
0F
A1
FF
A2
0F
A3
FF
A4 to FF
Fixed data-1 (Initialized data)
7.
9 Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing B, E, F, 7, 9 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address
Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
5-13
A
H
2.
Video Burst Level Adjustment
Adjust the burst level of the composite video signal output.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Video terminal of A/V OUT jack
(75 
 terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
C7
Specified Value
A = 286 
±
 5 mVp-p (NTSC)
A = 300 
±
 5 mVp-p (PAL)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
4
F1
04
3
D
C7
Change the data and set the
burst level (A) to the
specified value.
4
D
C7
Press PAUSE button
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
4
F1
00
2
0
01
00
A
H
Fig. 5-1-11
Fig. 5-1-12
1-3.
VIDEO SYSTEM ADJUSTMENTS
1.
Video Sync Level Adjustment
Adjust the sync level of the composite video signal output.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Video terminal of A/V OUT jack
(75 
 terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
C6
Specified Value
A = 286 
±
 5 mVp-p (NTSC)
A = 300 
±
 5 mVp-p (PAL)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
4
F1
04
Change the data and set the
3
D
C6
sync level (A) to the specified
value.
4
D
C6
Press PAUSE button
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
4
F1
00
2
0
01
00
5-14
1-4.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat-
isfied.
Note:
For “CAMERA SYSTEM ADJUSTMENTS”, perform in
order of item numbers.
Data setting during camera system adjustments
Perform the following data setting before the camera system ad-
justments.
Menu setting:
1) VIDEO OUT of SET UP menu
.................................. NTSC (NTSC mode)
(This adjustment must be performed in NTSC mode, so don’t
set the menu setting to “PAL” )
Data setting method:
Order Page Address Data
Procedure
1
0
01
01
2
D
10
80
Press PAUSE button.
3
2
10
Check the bit values of bit3, bit4
and bit5 are “1”. (Note 1, 2)
4
D
11
40
Press PAUSE button.
5
D
10
81
Press PAUSE button.
5
6
C1
Check the data changes to “02”.
6
4
06
01
7
6
6C
01
8
Wait for 1 second.
9
B
75
00
Press PAUSE button.
Note 1
: For the bit values, refer to “5-2. SERVICE MODE”, “2-
3. 2. Bit value discrimination”.
Note 2:
In case of wrong data, select page: 2, address: 0A and set
data: 02.
Set the adjusting remote commander to normal rank, and
the power will be turned off and on automatically. Wait
for 0.167 second after the power on, and set the adjust-
ing remote commander to the service rank. Then, retry
from the step 1.
Note 3:
Repeat the “Data setting method”, if the power was turned
off and on during the “CAMERA SYSTEM ADJUST-
MENTS”.
After completing the camera system adjustments,
release the data setting:
Order Page Address Data
Procedure
1
4
06
00
2
6
6C
00
3
B
75
10
Press PAUSE button.
4
D
11
00
Press PAUSE button.
5
D
10
00
Press PAUSE button.
6
0
01
00
5-15
1.
HALL Adjustment
For detecting the position of lens iris, adjust the HALL AMP gain
and offset.
Mode
CAMERA
Subject
Not required
Measurement Point
Displayed data of page: 1 (Note 2)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
2E, 2F, 34, 35
Specified Value
10 to 18 during IRIS OPEN
75 to 7D during IRIS CLOSE
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of the unit OFF/ON.
Note 2:
The right 2 digits of the page: 1 displayed data of the
adjusting remote commander.
1:00:XX
    
Displayed data
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
3
6
94
14
4
6
95
79
5
6
01
6D
Press PAUSE button. (Note 3)
6
6
02
Check the data changes to “01”.
7
6
01
00
Press PAUSE button.
8
0
03
03
9
6
01
01
Press PAUSE button.
10
1
Check that the displayed data
(Note 2)
during IRIS OPEN satisfies
the specified value.
11
6
01
03
Press PAUSE button.
12
1
Check that the displayed data
(Note 2) during IRIS CLOSE
satisfies the specified value.
Note 3:
The adjustment data will be automatically input to page:
F, address: 2E, 2F, 34 and 35.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
6
01
00
Press PAUSE button.
3
6
94
00
4
6
95
00
5
Release the data setting
performed at step 2.
(Refer to page 5-14)
6
0
01
00
Page of 101
Display

Click on the first or last page to see other DSC-P30 / DSC-P50 (serv.man2) service manuals if exist.