DOWNLOAD Sony DSC-F717 (serv.man4) Service Manual ↓ Size: 521.86 KB | Pages: 56 in PDF or view online for FREE

Model
DSC-F717 (serv.man4)
Pages
56
Size
521.86 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-f717-sm4.pdf
Date

Sony DSC-F717 (serv.man4) Service Manual ▷ View online

DSC-F717
6-23
11. Auto White Balance 3200K Standard Data Input 3
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance standard data at 3200K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
80 to 83, 86, 87
Note 1:
Perform this data input after performing “Auto White
Balance 3200K Standard Data Input 2”.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3:
“Auto White Balance 3200K Standard Data Input 3” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
“Auto White Balance 3200K
Standard Data Input 2” is
completed.
2
6
37
06
3
6
01
0B
Press PAUSE button. (Note 4)
4
6
02
Check the data changes to
“01”.
Note 4:
The adjustment data will be automatically input to page:
F, address: 80 to 83 and 86 to 87.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Perform “Auto White
Balance 5800K Standard
Data Input 1”.
12. Auto White Balance 5800K Standard Data Input 1
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance standard data at 5800K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
Adjustment Address
88 to 91, A0 to A3, B1, B3
Note 1:
Perform this data input after performing “Auto White
Balance 3200K Standard Data Input 3”.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3:
“Auto White Balance 5800K Standard Data Input 1” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
“Auto White Balance 3200K
Standard Data Input 3” is
completed.
2
Place the C14 filter on the
lens.
3
F
A0
2B
Press PAUSE button.
4
F
A1
10
Press PAUSE button.
5
F
A2
5D
Press PAUSE button.
6
F
A3
E0
Press PAUSE button.
7
6
37
07
8
6
B6
03
9
6
01
11
Press PAUSE button.
10
6
38
Check the data changes to
“01”.
11
6
01
C3
Press PAUSE button. (Note 4)
12
6
02
Check the data changes to
“01”.
13
6
01
00
Press PAUSE button.
14
6
B6
00
15
6
37
08
16
6
01
A5
Press PAUSE button. (Note 4)
17
6
02
Check the data changes to
“01”.
Note 4:
The adjustment data will be automatically input to page:
F, address: 88 to 91, A0 to A3, B1 and B3.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Perform “Auto White
Balance 5800K Standard
Data Input 2”.
DSC-F717
6-24
14. Auto White Balance 5800K Standard Data Input 3
RadarW
RadarW
RadarW
Adjust the white balance standard data at 5800K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
Adjustment Address
98 to 9B, 9E, 9F
Note 1:
Perform this data input after performing “Auto White
Balance 5800K Standard Data Input 2”.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3:
“Auto White Balance 5800K Standard Data Input 3” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
“Auto White Balance 5800K
Standard Data Input 2” is
completed.
2
6
37
0C
3
6
01
A5
Press PAUSE button. (Note 4)
4
6
02
Check the data changes to
“01”.
Note 4:
The adjustment data will be automatically input to page:
F, address: 98 to 9B and 9E to 9F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Perform “Auto White
Balance 5800K Check 1”.
13. Auto White Balance 5800K Standard Data Input 2
RadarW
RadarW
RadarW
Adjust the white balance standard data at 5800K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
Adjustment Address
92 to 97
Note 1:
Perform this data input after performing “Auto White
Balance 5800K Standard Data Input 1”.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3:
“Auto White Balance 5800K Standard Data Input 2” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
“Auto White Balance 5800K
Standard Data Input 1” is
completed.
2
6
37
0A
3
6
01
A5
Press PAUSE button. (Note 4)
4
6
02
Check the data changes to
“01”.
Note 4:
The adjustment data will be automatically input to page:
F, address: 92 to 97.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Perform “Auto White
Balance 5800K Standard
Data Input 3”.
DSC-F717
6-25
Order Page Address Data
Procedure
21
0
03
04
22
1
Check that the displayed data
(Note 3) satisfied the R ratio
specified value.
23
0
03
05
24
1
Check that the displayed data
(Note 3) satisfied the B ratio
specified value.
25
0
03
2E
26
1
Check that the R-Y level data
(Note 3) satisfied the
specified value.
27
0
03
2F
28
1
Check that the B-Y level data
(Note 3) satisfied the
specified value.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Perform “Auto White
Balance 5800K Check 2”.
15. Auto White Balance 5800K Check 1
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Filter
Filter C14 for color temperature
correction
Measurement Point
Displayed data of Page: 1 (Note 3)
Measuring Instrument
Adjusting remote commander
Specified Value
R ratio: 2910 to 2D10
B ratio: 5BE0 to 5FE0
R-Y level data: 0076 to 0082
B-Y level data: 0078 to 0084
Note 1:
Perform this data input after performing “Auto White
Balance 5800K Standard Data Input 3”.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
Order Page Address Data
Procedure
1
“Auto White Balance 5800K
Standard Data Input 3” is
completed.
2
6
37
13
3
6
B6
03
4
6
01
11
Press PAUSE button.
5
6
38
Check the data changes to
“01”.
6
6
01
C3
Press PAUSE button.
7
6
02
Check the data changes to
“01”.
8
0
03
04
9
1
Check that the displayed data
(Note 3) satisfied the R ratio
specified value.
10
0
03
05
11
1
Check that the displayed data
(Note 3) satisfied the B ratio
specified value.
12
0
03
2C
13
1
Check that the R-Y level data
(Note 3) satisfied the
specified value.
14
0
03
2D
15
1
Check that the B-Y level data
(Note 3) satisfied the
specified value.
16
6
01
00
Press PAUSE button.
17
6
B6
00
18
6
37
14
19
6
01
3F
Press PAUSE button.
20
6
02
Check the data changes to
“01”.
DSC-F717
6-26
17. Auto White Balance 5800K Check 3
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of page: F, address
9A, 9B
Measuring Instrument
Adjusting remote commander
Specified Value 1
23 to 9B
Specified Value 2
00 to 30, DA to FF
Note 1:
Perform this check after “Auto White Balance 5800K
Check 2” without a break.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Checking method:
Order Page Address Data
Procedure
1
“Auto White Balance 5800K
Check 2” is completed.
2
F
9A
Check that the data specified
value 1.
3
F
9B
Check that the data specified
value 2.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
Perform “Auto White
Balance 3200K Check 1”.
16. Auto White Balance 5800K Check 2
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of page: F, address:
94, 95
Measuring Instrument
Adjusting remote commander
Specified Value 1
11 to 4D
Specified Value 2
00 to 1D, DC to FF
Note 1:
Perform this check after “Auto White Balance 5800K
Check 1” without a break.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Checking method:
Order Page Address Data
Procedure
1
“Auto White Balance 5800K
Check 1” is completed.
2
Remove the C14 filter on the
lens.
3
F
94
Check that the data specified
value 1.
4
F
95
Check that the data specified
value 2.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
Perform “Auto White
Balance 5800K Check 3”.
Page of 56
Display