Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-f717-sm4.pdf
Date

Sony DSC-F717 (serv.man4) Service Manual ▷ View online

DSC-F717
6-19
4.
Flange Back Check
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Siemens star
(1.0 m from the front of the lens)
(Luminance: 200 to 400 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Specified value
Focused at the TELE end and
WIDE end
Checking method:
Order Page Address Data
Procedure
1
Place the Siemens star 1.0 m
from the front of the lens.
2
To open the IRIS , decrease
the luminous intensity to the
Siemens star up to a point
before noise appear on the
image.
3
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
4
B
3D
Note down the data.
5
B
3D
50
Press PAUSE button.
(Note 1)
6
6
90
00
7
6
91
04
8
6
92
D0
9
6
93
5A
10
6
01
79
Press PAUSE button.
11
6
07
Check the data changes to
“01”.
12
6
2C
01
13
6
01
00
Press PAUSE button.
14
While observe the TV
monitor, change the zoom to
the WIDE end and check that
the lens is focused.
Note 1:
How to find the data
Decrease the data of page: B, address: 3D until four sides
of a black frame can be seen on the monitor, then find
the value. The largest value under this condition will be
the setting value. If the value is less than 50, change
monitors.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
2C
00
2
6
91
00
3
6
92
00
4
6
93
00
5
B
3D
Set data noted down at step
4, and press PAUSE button.
6
Release the data setting
performed at step 3.
(Refer to page 6-14)
DSC-F717
6-20
5.
F No. Compensation
RadarW
RadarW
RadarW
Compensate the unevenness of the iris meter sensitivity.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
5E to 64
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”.
(Refer to page 6-15)
3
6
01
BB
Press PAUSE button.
(Note 2)
4
6
02
Check the data changes to
“01”.
Note 2:
The adjustment data will be automatically input to page:
F, address: 5E to 64.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 6-14)
6.
Mechanical Shutter Adjustment
RadarW
RadarW
RadarW
Adjust the period which the mechanical shutter is closed, and com-
pensate the exposure.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
B8 to D7
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”.
(Refer to page 6-15)
3
6
01
AD
Press PAUSE button.
(Note 2)
4
6
02
Check the data changes to
“01”.
5
6
AB
Check the data is “00”.
Note 2:
The adjustment data will be automatically input to page:
F, address: B8 to D7.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 6-14)
DSC-F717
6-21
7.
Light Value  Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the standard LV value.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of page: 1 (Note
2) and page: F, address: 65
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
65 to 67
Specified Value
AE level 1: 0FE0 to 1020
AE level 2: 37 to 4F
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”.
(Refer to page 6-15)
3
6
01
0D
Press PAUSE button.
(Note 3)
4
6
02
Check the data changes to
“01”.
5
0
03
06
6
1
Check that the displayed data
(Note 2) satisfies the AE
level 1 specified value.
7
F
65
Check that the displayed data
satisfies the AE level 2
specified value.
Note 3:
The adjustment data will be automatically input to page:
F, address: 65 to 67.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
0
03
00
3
Release the data setting
performed at step 1.
(Refer to page 6-14)
8.
Mixed Color Cancel Adjustment
RadarW
RadarW
RadarW
To perform mixed color cancel adjustment based on data of each
color in color bar.
Mode
CAMERA
Subject
Color bar chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
6E and 6F
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”.
(Refer to page 6-15)
3
7
12
Note down the data.
4
7
12
00
Press PAUSE button.
5
6
01
D7
Press PAUSE button.
6
6
01
D5
Press PAUSE button.
(Note 2)
7
6
02
Check the data changes to
“01”.
Note 2:
The adjustment data will be automatically input to page:
F, address: 6E and 6F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
7
12
Set the data noted down at
step 3, and press PAUSE
button.
3
Release the data setting
performed at step 1.
(Refer to page 6-14)
DSC-F717
6-22
10. Auto White Balance 3200K Standard Data Input 2
RadarW
RadarW
RadarW
Adjust the white balance standard data at 3200K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
7A to 7F
Note 1:
Perform this data input after performing “Auto White
Balance 3200K Standard Data Input 1”.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3:
“Auto White Balance 3200K Standard Data Input 2” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
“Auto White Balance 3200K
Standard Data Input 1” is
completed.
2
6
37
04
3
6
01
0B
Press PAUSE button. (Note 4)
4
6
02
Check the data changes to
“01”.
Note 4:
The adjustment data will be automatically input to page:
F, address: 7A to 7F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Perform “Auto White
Balance 3200K Standard
Data Input 3”.
9.
Auto White Balance 3200K Standard Data Input 1
RadarW
RadarW
RadarW
Adjust the white balance standard data at 3200K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
70 to 79, B0, B2, B4
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
“Auto White Balance 3200K Standard Data Input 1” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”. (Refer to page 6-15)
3
6
37
01
4
6
B6
03
5
6
01
11
Press PAUSE button.
6
6
38
Check the data changes to
“01”.
7
6
01
C1
Press PAUSE button. (Note 3)
8
6
02
Check the data changes to
“01”.
9
6
01
00
Press PAUSE button.
10
6
B6
00
11
6
37
02
12
6
01
0B
Press PAUSE button. (Note 3)
13
6
02
Check the data changes to
“01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 70 to 79, B0, B2 and B4.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Perform “Auto White
Balance 3200K Standard
Data Input 2”.