DOWNLOAD Sony DSC-F717 (serv.man4) Service Manual ↓ Size: 521.86 KB | Pages: 56 in PDF or view online for FREE

Model
DSC-F717 (serv.man4)
Pages
56
Size
521.86 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-f717-sm4.pdf
Date

Sony DSC-F717 (serv.man4) Service Manual ▷ View online

DSC-F717
6-31
23. CCD Black Defect Compensation
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of page: 6,
address: 55
Measuring Instrument
Adjusting remote commander
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Check that there are no dust, no dirt and reflection of the
clear chart.
Note 3:
Any subject other than the clear chart should be in the
screen.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2
E
65
Note down the data.
3
E
65
4C
Press PAUSE button.
4
6
2C
01
5
6
90
00
6
6
91
03
7
6
92
00
8
6
93
00
9
6
01
79
Press PAUSE button.
10
6
30
08
11
6
07
Check the data changes to
“01”.
12
6
01
8D
Press PAUSE button.
13
6
02
Check the data changes to
“01”.
14
6
55
Check the data.
00 to 14 : Normal
15 to FF : Defective
(Note 4)
15
6
01
00
Press PAUSE button.
16
E
65
5A
Press PAUSE button.
17
6
01
89
Press PAUSE button.
18
6
02
Check the data changes to
“01”.
19
6
55
Check the data.
00: Normal
01 to FF: Defective
Note 4:
If the data is “00” at the check in this adjustment method
order #14, skip the orders from #15 to #19, and go for-
ward to “Processing after Completing Adjustment.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
30
00
4
6
91
00
5
E
65
Set data noted down at step
2, and press PAUSE button.
6
Release the data setting
performed at step 1.
(Refer to page 6-14)
DSC-F717
6-32
24. CCD Linearity Check (Monitoring)
Check that CCD output at monitoring keeps being straight even
input is changed.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of Page: 1 (Note 1)
Measuring Instrument
Adjusting remote commander
Specified Value 1
97 to 103 (decimal notation)
Specified Value 2
97 to 105 (decimal notation)
Note 1:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”. (Refer to page 6-15)
3
7
09
04
Press PAUSE button.
4
6
C8
26
5
6
13
A8
6
6
14
90
7
Wait for 2 seconds.
8
0
03
40
9
1
Read displayed data. (Note 1)
10
Get average value of
displayed data of ten times,
and named average value as
D
R/GRef
.
11
Convert D
R/GRef
 to decimal
notation, and obtain D
R/GRef
’.
12
0
03
41
13
1
Read displayed data. (Note 1)
14
Get average value of
displayed data of ten times,
and named average value as
D
B/GRef
.
15
Convert D
B/GRef
 to decimal
notation, and obtain D
B/GRef
’.
16
B
72
Note down the data.
17
B
72
50
Press PAUSE button.
18
Wait for 2 seconds.
19
0
03
40
20
1
Read displayed data. (Note 1)
21
Get average value of
displayed data of ten times,
and named average value as
D
R/GHi
.
22
Convert D
R/GHi
 to decimal
notation, and obtain D
R/GHi
’.
23
0
03
41
Order Page Address Data
Procedure
24
1
Read displayed data. (Note 1)
25
Get average value of
displayed data of ten times,
and named average value as
D
B/GHi
.
26
Convert D
B/GHi
 to decimal
notation, and obtain D
B/GHi
’.
27
B
72
Set data noted down at step
16, and press PAUSE button.
28
6
14
8B
29
Wait for 2 seconds.
30
0
03
40
31
1
Read displayed data. (Note 1)
32
Get average value of
displayed data of ten times,
and named average value as
D
R/GLow
.
33
Convert D
R/GLow
 to decimal
notation, and obtain D
R/GLow
’.
34
0
03
41
35
1
Read displayed data. (Note 1)
36
Get average value of
displayed data of ten times,
and named average value as
D
B/GLow
.
37
Convert D
B/GLow
 to decimal
notation, and obtain D
B/GLow
’.
38
Calculate D
1
 by using the
following equation. (decimal
calculation)
D
1
 = (D
R/GHi
’ 
÷
 D
R/GRef
’) 
×
 100
39
Check that calculated D
1
satisfies the specified value
1.
40
Calculate D
2
 by using the
following equation. (decimal
calculation)
D
2
 = (D
B/GHi
’ 
÷
 D
B/GRef
’) 
×
 100
41
Check that calculated D
2
satisfies the specified value
2.
42
Calculate D
3
 by using the
following equation. (decimal
calculation)
D
3
 = (D
R/GLow
’ 
÷
 D
R/GRef
’) 
×
 100
43
Check that calculated D
3
satisfies the specified value
1.
44
Calculate D
4
 by using the
following equation. (decimal
calculation)
D
4
 = (D
B/GLow
’ 
÷
 D
B/GRef
’) 
×
 100
45
Check that calculated D
4
satisfies the specified value
1.
DSC-F717
6-33
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
C8
00
2
0
03
00
3
7
09
00
Press PAUSE button.
4
6
13
00
5
6
14
00
6
Release the data setting
performed at step 1.
(Refer to page 6-14)
DSC-F717
6-34
25. CCD Linearity Check (Caputure)
Check that CCD output at caputure keeps being straight even in-
put is changed.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of Page: 1 (Note 1)
Measuring Instrument
Adjusting remote commander
Specified Value
97 to 103 (decimal notation)
Note 1:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”. (Refer to page 6-15)
3
7
09
04
Press PAUSE button.
4
6
C8
26
5
6
13
A8
6
6
14
90
7
Wait for 2 seconds.
8
6
01
F9
Press PAUSE button.
9
Wait for 3 seconds.
10
0
03
40
11
1
Read displayed data. (Note 1)
12
This data is named D
R/GRef
.
13
Convert D
R/GRef
 to decimal
notation, and obtain D
R/GRef
’.
14
0
03
41
15
1
Read displayed data. (Note 1)
16
This data is named D
B/GRef
.
17
Convert D
B/GRef
 to decimal
notation, and obtain D
B/GRef
’.
18
6
01
00
Press PAUSE button.
19
B
72
Note down the data.
20
B
72
50
Press PAUSE button.
21
Wait for 2 seconds.
22
6
01
F9
Press PAUSE button.
23
9
Wait for 3 seconds.
24
0
03
40
25
1
Read displayed data. (Note 1)
26
This data is named D
R/GHi
.
27
Convert D
R/GHi
 to decimal
notation, and obtain D
R/GRHi
’.
28
0
03
41
29
1
Read displayed data. (Note 1)
30
This data is named D
B/GHi
.
Order Page Address Data
Procedure
31
Convert D
B/GHi
 to decimal
notation, and obtain D
B/GHi
’.
32
6
01
00
Press PAUSE button.
33
B
72
Set data noted down at step
19, and press PAUSE button.
34
6
14
8B
35
Wait for 2 seconds.
36
6
01
F9
Press PAUSE button.
37
Wait for 3 seconds.
38
0
03
40
39
1
Read displayed data. (Note 1)
40
This data is named D
R/GLow
.
41
Convert D
R/GLow
 to decimal
notation, and obtain D
R/GLow
’.
42
0
03
41
43
1
Read displayed data. (Note 1)
44
This data is named D
B/GLow
.
45
Convert D
B/GLow
 to decimal
notation, and obtain D
B/GLow
’.
46
Calculate D
1
 by using the
following equation. (decimal
calculation)
D
1
 = (D
R/GHi
’ 
÷
 D
R/GRef
’) 
×
 100
47
Check that calculated D
1
satisfies the specified value.
48
Calculate D
2
 by using the
following equation. (decimal
calculation)
D
2
 = (D
B/GHi
’ 
÷
 D
B/GRef
’) 
×
 100
49
Check that calculated D
2
satisfies the specified value.
50
Calculate D
3
 by using the
following equation. (decimal
calculation)
D
3
 = (D
R/GLow
’ 
÷
 D
R/GRef
’) 
×
 100
51
Check that calculated D
3
satisfies the specified value.
52
Calculate D
4
 by using the
following equation. (decimal
calculation)
D
4
 = (D
B/GLow
’ 
÷
 D
B/GRef
’) 
×
 100
53
Check that calculated D
4
satisfies the specified value.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
C8
00
3
0
03
00
4
7
09
00
Press PAUSE button.
5
6
13
00
6
6
14
00
7
Release the data setting
performed at step 1.
(Refer to page 6-14)
Page of 56
Display