Sony ZS-PS30CP Service Manual ▷ View online

ZS-PS30CP
17
SECTION  3
TEST  MODE
EEPROM  CLR
It can clear the EEPROM.
Procedure:
1.  While pressing two buttons of [DISPLAY] and [
>
] simulta-
neously and connect the AC power cord.
2.  The EEPROM is cleared, and the message “CLR” is displayed 
on the liquid crystal display, then becomes the standby state.
PANEL  AND  KEY  TEST
It can check the liquid crystal display and button.
Procedure:
1.  While pressing two buttons of [x] and [DISPLAY] simultane-
ously and connect the AC power cord.
2.  It enters the panel and key test mode, and all segments on the 
liquid crystal display light up.
3.  Each time a button is pressed, the segments on the liquid crys-
tal display corresponding to each button disappear.
4.  When all buttons are pressed, all segments on the liquid crystal 
display disappear.
5.  When the [DISPLAY] button is pressed, becomes the standby 
state.
Releasing method:
Disconnect the AC power cord.
CD  TEST  MODE
It can check the focus error and tracking error.
Procedure:
1.  Connect the oscilloscope to TP895 (FEI) and TP814 (GND) on 
the MAIN board.
+
MAIN board
TP895 (FEI)
TP814 (GND)
oscilloscope
2.  Open the CD lid.
3. While 
pressing 
[x] button for around 8 seconds and connect 
the AC power cord.
4.  It enters the CD test mode, and the message “TEST 1” is dis-
played on the liquid crystal display.
5.  When the message “TEST 1” is displayed on the liquid crystal 
display, press the [
u
] button.
6.  It enters the focus error test mode, and the message “FE” is 
displayed on the liquid crystal display.
7.  When the CD disc is placed and CD lid is closed, focus error 
starts.
8. Confi rm that oscilloscope waveform is as shown in the fi gure 
below.
1.2 ± 0.6 Vp-p
VOLT/DIV: 200 mV
TIME/DIV: 2 ms
9.  Disconnect the AC power cord to release the focus error test 
mode.
10.  Connect the oscilloscope to TP805 (TEI) and TP814 (GND) on 
the MAIN board.
+
MAIN board
TP805 (TEI)
TP814 (GND)
oscilloscope
11.  Open the CD lid.
12. While pressing [x] button for around 8 seconds and connect 
the AC power cord.
13. It enters the CD test mode, and the message “TEST 1” is dis-
played on the liquid crystal display.
14. When the [
>
] button is pressed, the message on the liquid 
crystal display change to “TEST 2”.
 
(When the [
>
] button is pressed again, the message on the 
liquid crystal display change to “TEST 1”)
15. It enters the tracking error test mode, and the message “TE” is 
displayed on the liquid crystal display.
16. When the CD lid is closed, tracking error starts.
17. Confi rm that oscilloscope waveform is as shown in the fi gure 
below.
1.2 ± 0.6 Vp-p
VOLT/DIV: 500 mV
TIME/DIV: 2 ms
Releasing method:
Press the [POWER] button or disconnect the AC power cord.
Connection Location:
– MAIN Board (Conductor Side) –
TP814
(GND)
TP895
(FEI)
TP805
(TEI)
ZS-PS30CP
18
SECTION  4
ELECTRICAL  CHECKS
TUNER SECTION      0 dB = 1 V
[AM]
Setting:
Function: RADIO
Band: AM
AM RF signal
generator
30% amplitude 
modulation by 
400 Hz signal
Output level: 
as low as possible
Put the lead-wire
antenna close to
the unit.
HP JACK board 
i
 jack (J302)
unit
+
í
level meter
32 
:
[FM]
Setting:
Function: RADIO
Band: FM
FM RF signal
generator
75 kHz frequency
deviation by
1 kHz signal
Output level: 
as low as possible
HP JACK board 
i
 jack (J302)
unit
0.01
PF
+
í
level meter
MAIN board 
TP814 (GND)
32 
:
MAIN board 
JW101
Note: Perform FM frequency coverage check after removing FM tele-
scopic antenna (ANT1). 
no mark: Chilean, Peruvian, Asian, Taiwan and Argentina models
(         ): Panamanian model
AM  FREQUENCY  COVERAGE  CHECK
Check that reading on level meter is the maximum
Confi rmation
531 (530) kHz
Confi rmation
1,602 (1,710) kHz
FM  FREQUENCY  COVERAGE  CHECK
Check that reading on level meter is the maximum
Confi rmation
87.5 MHz
Confi rmation
108 MHz
CD  SECTION
Note:
1.  CD block is basically constructed to operate without adjustment.
2.  Use YEDS-18 disc (Part No. 3-702-101-01) unless otherwise indicat-
ed.
3.  Use an oscilloscope with more than 10 M
 impedance.
4.  Clean the object lens by an applicator with neutral detergent when the 
signal level is low than specifi ed value with the following checks.
5.  Check the focus bias check when optical pick-up block is replaced.
FOCUS  BIAS  CHECK
+
MAIN board
TP804 (RF)
TP711 (VREF)
oscilloscope
Procedure:
1.  Connect the oscilloscope to TP804 (RF) and TP711 (VREF) 
on the MAIN board.
2.  In the standby state, press the [POWER] button to turn the 
power on.
3.  Press the [CD] button to turn the CD function.
4.  Set the disc (YEDS-18) and press the [
u
] button to playback.
5. Confi rm that oscilloscope waveform is as shown in the fi gure 
below. (eye pattern)
 
A good eye pattern means that the diamond shape (
) in the 
center of the waveform can be clearly distinguished. 
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level: 1.5 Vp-p
Connection Location:
– MAIN Board (Conductor Side) –
TP814
(GND)
TP804
(RF)
TP711
(VREF)
JW101
Ver. 1.1
ZS-PS30CP
ZS-PS30CP
19
19
OP1
OPTICAL PICK-UP BLOCK
(DA11MMVGP)
A
B
C
D
E
F
PD
LD
AUTOMATIC
POWER CONTROL
Q701
90 LDO
99 FOO
100 TRO
2 DMO
1 FMO
40 MOTOR-MUTE
FC+
26
24
F+
FC–
27 F–
TR+
18 T+
TR–
17 T–
12 SL+
11 SL–
2 SP+
1 SP–
86 TPI (F)
89 MDI
VC
88 VRO
87 TNI (E)
84 FPI2 (D)
82 FNI2 (C)
85 FPI1 (B)
83 FNI1 (A)
78 AGCI
R-CH
(FIN)
23
VREF
79
RFO
22
LO
24
RO
93
USB DATA
35 USB DATA
92
USB BCK
D+
D–
38 USB BCK
71
LRCK
39 USB LRCK
D+
85
79
D–
80
73
USB RX
32 USB TX
84
USB TX
31 USB RX
94
USB GATE
17 USB GATE
96
USB REQ
43 USB REQ
2
USB PWR
55 USB PWR
1
RST
45 USB RESET
20
(TIN)
9
(SLIN)
3
SPIN
FOCUS/TRACKING COIL DRIVE,
SLED/SPINDLE MOTOR DRIVE
IC701
7
MUTE
USB CONTROLLER
IC1001
J1001
3
2
X1001
9MHz
X2
75
X1
CD DSP, 
SYSTEM CONTROLLER
IC801 (1/2)
(SLED)
M
(SPINDLE)
M
FM/AM RECEIVER
IC1
6
SCL
44
A MUTE
5
SDA
1 IN  LCD
5 IN  L  AU
13 VOLIN L
9 IN  L  TU
INPUT SELECTOR, ELECTRICAL VOLUME
IC303
15 RST
17 SCLK
18 SDIO
23
ROUT
24
LOUT
12
ICOUT L
19
X1
32.768kHz
RCLK
3
GPO3/
DCLK
27
X801
16.9344MHz
XI
28
XO
11
X802
4.19MHz
MXI
52
O-SHIFT2
10
MXO
: AUDIO IN
: CD PLAY
: FM
: AM
SIGNAL PATH
R-ch is omitted due to same as L-ch.
R-CH
R-CH
R-CH
AUDIO IN
J301
ANT1
FM TELESCOPIC
ANTENNA
L1
AM FERRITE-ROD
ANTENNA
8 FMI
12 AMI
34
I2C SDA
33
I2C SCL
56
TU-RESET
MUTING
Q102
A
STBY
25
L OUT
28 27
Q801, 802
CLOCK SHIFT
51
O-SHIFT1
CLK
DA
TA
Q801
Q802
EEPROM
IC805
POWER AMP
IC302
R-CH
J302
i
SP101
(L-CH)
SP201
(R-CH)
: USB
SECTION  5
DIAGRAMS
5-1.  BLOCK  DIAGRAM - MAIN Section -
ZS-PS30CP
ZS-PS30CP
20
20
5-2.  BLOCK  DIAGRAM - PANEL/POWER  SUPPLY Section -
USB +3.3V
3 KEY1-I
S410 – 416
(FRONT PANEL KEYS)
4 KEY2-I
D806
S402 – 409
(FRONT AND TOP PANEL KEYS)
30 POWER KEY
61 DATA
59 WR
60 CS
CD DSP,
SYSTEM CONTROLLER
IC801 (2/2)
LCD401
LIQUID
CRYSTAL
DISPLAY
D401
OPR/BATT
S401
POWER
D808
~ AC IN
J901
A
STBY
F901
F902
RECT
D901 – 904
DRY BATTERY
SIZE “C”
(IEC DESIGNATION R14)
6PCS. 9V
T901
POWER
TARANSFORMER
57
ACDC CHK
41
USB 5V ON
62
USB SW FLG
7
6V CHK
18
RESET
+6.2V
REGULATOR
IC901
+3.3V
REGULATOR
IC802
+3.3V
REGULATOR
Q905
58
USB SW EN
SWITCHING
REGULATOR
IC902
VBUS
SWITCH
IC1002
46
P CON
VBUS +5V
+6.2V
TUNER +3.3V
+3.3V
SYSTEM +3.3V
6
BATT-CHK-H
47
USB 3.3V CHK
+9V
MEMORY +1.5V
3
WR
4
DATA
1
CS
LIQUID CRYSTAL
DISPLAY DRIVER
IC806
SEG1 – 
SEG29
COM0 – 
COM3
5 CD LLIMIT/LID IN
SYSTEM +3.3V
S801
CD LID
OPEN/CLOSE
DETECT
S701
(LIMIT)
+3.3V
REGULATOR
Q955
SYSTEM +1.5V
RESET SIGNAL
GENERATOR
IC807
B+ SWITCH
Q951 – 953
B+ SWITCH
Q804, 805
+3.3V
+1.5V
REGULATOR
IC803
+1.5V
REGULATOR
IC804
(Except Argentina)
Ver. 1.1
Page of 48
Display