DOWNLOAD Sony STR-DA7100ES Service Manual ↓ Size: 52.09 MB | Pages: 127 in PDF or view online for FREE

Model
STR-DA7100ES
Pages
127
Size
52.09 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
str-da7100es.pdf
Date

Sony STR-DA7100ES Service Manual ▷ View online

21
STR-DA7100ES
3-6. DC FAN BLOCK
2
two screws
(BV/ring)
1
connector
(CN5002)
3
two screws
(BV/ring)
4
DC fan block
ql
three screws
(BVTP3 
×
 8)
qk
three screws
(BVTP3 
×
 8)
qf
eight screws
(BVTP3 
×
 8)
4
wire (flat type)
(tuner)
3
connector (CN851)
6
four connectors
(CN3801, CN3803, CN3806, CN3809)
9
three connectors
(CN603, CN602, CN601)
8
two connectors
(CN606, CN604)
5
two connectors 
(CN3807, CN3808)
2
connector 
(CNP742)
1
connector 
(CN1)
7
connector 
(TP3501)
qg
screw
(BVTP3 
×
 8)
qd
two screws
(BVTP3 
×
 8)
qs
screw (BVTP3 
×
 8)
0
two screws 
(BVTP3 
×
 8)
(US, Canadian, AEP models)
qj
screw
(BV3 
×
 8)
qa
screw (BV3 
×
 8)
qh
six screws
(BV/ring)
w;
back panel block
3-7. BACK PANEL BLOCK
22
STR-DA7100ES
1
connector
(CN5231)
2
connector
(CN5261)
3
connector
(CN5251)
4
connector
(CN5206)
5
connector
(CN5263)
6
connector
(CN5002)
8
connector
(CN5280)
7
connector
(CN5201)
9
connector
(CN5240)
0
SP-TERM COM board
HDMI board
qa
connector
(CN5401)
qh
two connectors
(CNR207, CNR208)
qg
MOTHER COM board
qs
Remove five solders.
qf
three screws
(BVTP3 
×
 8)
qj
CONECT board
qd
screw
(BVTP3 
×
 8)
3-8. MOTHER COM BOARD
23
STR-DA7100ES
SECTION  4
TEST  MODE
TUNER FACTORY PRESET MODE
All preset contents are reset to the default setting.
Procedure:
1. While pressing the 
[SURR BACK DECODING]
  and 
[PRE-
SET TUNING --]
 buttons, press the
I/1
button to turn on the
main power.
2. The message “TUNER FACTORY PRESET” appears and the
present contents are reset to the default values.
MEMORY CLEARING MODE
All preset contents are cleared when this mode is activated. Use
this mode before returning the product to clients upon completion
of repair.
Procedure:
1. While pressing the [INPUT MODE] and [MEMORY/ENTER] but-
tons, press the  
I/1 
 button to turn on the main power.
2. The message “MEMORY CLEARING...” appears and the
memories are reset to the default values.
3. When done, the message “MEMORY CLEARED !” appears.
SWAP MODE
Procedure:
1. While pressing the 
[2CH]
 and 
[MEMORY/ENTER]
 buttons,
press the  
I/1 
 button to turn on the main power.
2. The message “SWAP MODE !” appears.
3. Press the 
[DISPLAY]
 button.
4. The message “–34.5” appears. (Volume level is “MID”)
5. Press the 
[DISPLAY]
 button once again.
6. The message “23.0” appears. (Volume level is “MAX”)
7. Press the 
[DISPLAY]
 button once again.
8. The message “–
∞” appears. (Volume level is “MIN”)
FLUORESCENT INDICATOR TUBE PATTERN
CHECK  MODE
All fluorescent segments are tested. When this test is activated, all
segments turn on at the same time, then each segment turns on one
after another.
Procedure:
1. While pressing the 
[DISPLAY]
 and 
[MEMORY/ENTER]
 but-
tons, press the  
I/1 
 button to turn on the main power.
2. All segments and all LEDs turn on.
TUNER AM STEP CHANGE (9 kHz/10 kHz) MODE
(US and Canadian models)
Either the 9 kHz step or 10 kHz step can be selected for the AM
channel step.
Procedure:
1. Press the  
I/1 
 button to turn on the main power.
2. Turn the [INPUT SELECTOR] dial to select the “AM” .
3. Press the  
I/1 
 button to turn off the main power.
4. While pressing the [PRESET TUNING +] or [TUNING +] but-
ton, press the  
I/1 
 button to turn on the main power.
5. Either the message “AM 9K STEP” or “AM 10K STEP” ap-
pears, Select the desired step.
SOUND FIELD CLEAR MODE
The preset sound field is cleared when this mode is activated. Use
this mode before returning the product to clients upon completion
of repair.
Procedure:
1. While pressing the 
[MUSIC]
 button, press the  
I/1 
 button to
turn on the main power.
2. The message “S. F. Initialize” appears and initialization is per-
formed.
COMMAND MODE CHANGE MODE
The command mode of the remote-commander which this set re-
ceives can be changed.
Procedure:
1. While pressing the 
[2CH]
 button, press the
I/1
button to turn
on the main power.
2. Either the message “COMMAND MODE [AV1]” or “COM-
MAND MODE [AV2]” appears. Select the desired mode.
SF LOCK ON/OFF CHANGE MODE
Procedure:
1. While pressing the 
[MUSIC]
 and 
[MEMORY/ENTER]
 buttons,
press the
I/1
button to turn on the main power.
2. Either the message “SF LOCK [OFF]” or “SF LOCK [ON]”
appears.
OPERATION CHECK OF i.LINK TERMINAL
Connect the set to a unit equipped with the i.LINK terminal to
check if the communication can be made correctly. By this opera-
tion check, a loose connection of the connector or a disconnection
of the i.LINK cable can be confirmed.
Procedure:
1. Press the
I/1
button to turn on the power, and press the [I.LINK]
button to set the function to the “i.LINK” so that the “No LINK”
is displayed
2. Turn on the power of the unit equipped with the i.LINK termi-
nal.
3. Connect the set to the unit equipped with the i.LINK terminal
using the i.LINK calbe.
At this time, check that “i.LINK CONNECTING”, is displayed
on the set.
4. After the display of “i.LINK CONNECTING”, check that the
equipment information is displayed
5. Moving the i.LINK cable with the i.LINK connection main-
tained, check that the “i.LINK CONNECTING” is not dis-
played.
If nothing is displayed in step 3 and 4, or if “i.LINK CONNECT-
ING” is displayed continuously, the i.LINK cable will be discon-
nected or the connector connection will be loose.
If “i.LINK CONNECTING” is displayed in step 5 though the cable
is not removed, the i.LINK cable will be disconnected or the con-
nector connection will be loose.
24
STR-DA7100ES
HISTORY MODE
The state that the set is used is memorized.
Procedure:
1. While pressing the 
[A.F.D]
 and 
[MEMORY/ENTER]
 buttons,
press the I
/1
button to turn on the power and “HISTORY
MODE” is displayed.
2. Press the [MAIN MENU] key of remote commander.
3. Each time the 
 ↑   ↓
  key of remote commander is pressed, the
item is switched in order as follows.
Note: The parameter is memorized when “PROTECTOR 21” is
generated, and it doesn’t update the parameter thereafter
when other protector is generated, the parameter when data
is updated every time, and protector was generated at the
end is memorized.
Items
Display
Detected protect code/channel
PRCT NO/CH: XX/XX
Number of protector is generated
PRCT COUNT: XXX
Total use time
TTL_TIME: XXXXH XXM
Sound field setting
XXXXXXXXXXXXXXXX
Input when protect is detected
INPUT: XXXXXXXXXX
Input mode setting
INMODE: XXXXXXXXXXXX
Input mode under lick state
DSEL: XXXXXXXXXXXXXXX
Stream under input
STREAM: XXXXXXX
Channel information
CONFIG:XXXXXXX
State of headphone
HEAD PHONE: XXX
Volume
VOL: XXXdB
EQ setting value
BASS:    XXXdB
TREB:    XXXdB
Lv FL/FR  XXXX/XXXX
Level collection value
Lv SL/SR  XXXX/XXXX
each channel
Lv CT/SW  XXXX/XXXX
Lv BL/BR  XXXX/XXXX
Total time of power on
TTL_P_ON: XXXXH XXM
Page of 127
Display