– 5 –
Flexible Circuit Board Repairing
• Keep the temperature of the soldering iron around 270 ˚C dur-
ing repairing.
• Do not touch the soldering iron on the same conductor of the
circuit board (within 3 times).
• Be careful not to apply force on the conductor when soldering
or unsoldering.
Notes on chip component replacement
• Never reuse a disconnected chip component.
• Notice that the minus side of a tantalum capacitor may be dam-
aged by heat.
ADVARSEL
Eksplosjonsfare ved feilaktig skifte av batteri.
Benytt samme batteritype eller en tilsvarende type
anbefalt av apparatfabrikanten.
Brukte batterier kasseres i henhold til fabrikantens
instruksjoner.
VARNING
Explosionsfara vid felaktigt batteribyte.
Använd samma batterityp eller en likvärdig typ som
 rekommenderas av apparattillverkaren.
Kassera använt batteri enligt gällande föreskrifter.
VAROITUS
Paristo voi räjähtää, jos se on virheellisesti asennettu.
Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin.
Hävitä käytetty paristo valmistajan ohjeiden mukaisesti.
ADVARSEL!
Lithiumbatteri-Eksplosionsfare ved fejlagtig håndtering.
Udskiftning må kun ske med batteri
af samme fabrikat og type.
Levér det brugte batteri tilbage til leverandøren.
CAUTION
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended by
the manufacturer.
Discard used batteries according to the manufacturer’s instruc-
tions.
CAUTION
Use of controls or adjustments or performance of procedures
other than those specified herein may result in hazardous ra-
diation exposure.
Laser component in this product is capable of emitting radia-
tion exceeding the limit for Class 1.
This appliance is classified as
a CLASS 1 LASER product.
The CLASS 1 LASER PROD-
UCT MARKING is located on
the rear exterior.
This caution
label is located
inside the unit.
ATTENTION  AU  COMPOSANT  AYANT  RAPPORT
À  LA  SÉCURITÉ!
LES  COMPOSANTS  IDENTIFIÉS  PAR  UNE  MARQUE  
!
SUR  LES  DIAGRAMMES  SCHÉMATIQUES  ET  LA  LISTE
DES  PIÈCES  SONT  CRITIQUES  POUR  LA  SÉCURITÉ
DE  FONCTIONNEMENT.  NE  REMPLACER  CES  COM-
POSANTS  QUE  PAR  DES  PIÈCES  SONY  DONT  LES
NUMÉROS  SONT  DONNÉS  DANS  CE  MANUEL  OU
DANS  LES  SUPPLÉMENTS  PUBLIÉS  PAR  SONY.
SAFETY-RELATED  COMPONENT  WARNING!!
COMPONENTS  IDENTIFIED  BY  MARK  
!
  OR  DOTTED
LINE  WITH  MARK  
!
  ON  THE  SCHEMATIC  DIAGRAMS
AND  IN  THE  PARTS  LIST  ARE  CRITICAL  TO  SAFE
OPERATION.  REPLACE  THESE  COMPONENTS  WITH
SONY  PARTS  WHOSE  PART  NUMBERS  APPEAR  AS
SHOWN  IN  THIS  MANUAL  OR  IN  SUPPLEMENTS  PUB-
LISHED  BY  SONY.
– 6 –
HOW  TO  OPEN  THE  DISC  TRAY  WHEN  POWER SWITCH  TURNS OFF
1 Remove the fourteen screws (3 
×
 8) from the bottom plate (refer to page 87).
2 Remove the bottom plate.
3 Rotate the pulley gear in the arrow direction A, and open the tray assembly in the
arrow direction B.
Forced Reset
The system microprocessor can be reset in the following procedure.
Use these procedure when the unit cannot be operated normally due to the overrunning of the microprocessor, etc.
Procedure :
Disconnect the power plug from the socket, and short-circuit the pin 1 and pin 3 of CN703 on the BT board with tweezers, etc. to
discharge the backup battery.
[BT Board] (Conductor Side)
pully gear
tray assembly
A
B
CN703
BT701
1
3
– 7 –
JIG  FOR  CHECKING  BD  BOARD  WAVEFORM
The special jig (J-2501-149-A) is useful for checking the waveform of the BD board. The manes of terminals and the checking items to be
performed are shown as follows.
GND : Ground
I + 3 V : For measuring IOP (Check the deterioration of the optical pick-up laser)
IOP
: For measuring IOP (Check the deterioration of the optical pick-up laser)
TE
: TRK error signal (Traverse adjustment)
VC
: Reference level for checking the signal
RF
: RF signal (Check jitter)
RF
5P connector
6P connector
VC
TEO
IOP
I+3V
GND
RF
VC
TEO
MDM-3
MDM-5
MDM-6
IOP
I-3V
VC
RF
TEO
IOP
I+3V
GND
VC
RF
TEO
IOP
I+3V
GND
1
5
1
6
– 8 –
IOP Data Recording and Display When Pickup and Non-volatile Memory (IC171 of BD board) are Replaced
The IOP value labeled on the pick-up can be recorded in the non-volatile memory. By recording the value, it will eliminate the need to look
at the value on the label of the optical pick-up. When replacing the pick-up or non-volatile memory (IC171 of BD board), record the IOP
value on the pick-up according to the following procedure.
Record Precedure:
1. While pressing the 
[        AMS        ]
 knob and 
p button, connect the power plug to the outlet, and release the 
[        AMS        ]
 knob
and 
p button.
2. Rotate the 
[        AMS        ]
 knob to display “[Service]”, and press the 
[YES]
 button.
3. Rotate the 
[        AMS        ]
 knob to display “lop.Write” (C28), and press the 
[YES]
 button.
4. The display becomes “Ref=@@@.@” (@ is an arbitrary number) and the numbers which can be changed will blink.
5. Input the IOP value written on the optical pick-up.
To select the number : Rotate the 
[        AMS        ]
 knob.
To select the digit
: Press the 
[        AMS        ]
 knob.
6. When the 
[YES]
 button is pressed, the display becomes “Measu=@@@.@” (@ is an arbitrary number).
7. As the adjustment results are recorded for the 6 value. Leave it as it is and press the 
[YES]
 button.
8. “Complete!” will be displayed momentarily. The value will be recorded in the non-volatile memory and the display will become “Iop
Write”.
9. Press the 
[REPEAT]
 button to complete. “Standby” will be displayed.
Display Precedure:
1. While pressing the 
[        AMS        ]
 knob and  
p  button, connect the power plug to the outlet, and release the 
[        AMS        ]
 knob
and  
p  button.
2. Rotate the 
[        AMS        ]
 knob to display “[Service]”, and press the 
[YES]
 button.
3. Rotate the 
[        AMS        ]
 knob to display “lop.Read” (C27).
4. “@@.@/##.#” is displayed and the recorded contents are displayed.
@@.@ : indicates the Iop value labeled on the pick-up.
##.#
: indicates the Iop value after adjustment
5. To end, press the 
[        AMS        ]
 button or 
[MENU/NO]
 button to display “Iop Read”. Then press the 
[REPEAT]
 button to display
“Standby”.
[  ]
[  ]
±
±
±
±
±
±
±
±
±
±
[  ]
±
[  ]
Page of 88