– 25 –
·
P
REC
–SYNC
A.SPACE
OVER
B
A-
TRACK
DISC
DATE
CLOCK
When Off
Contents
Display
When Lit
During continuous playback (CLV: ON)
Tracking servo OFF
Recording mode ON
CLV low speed mode
ABCD adjustment completed
Tracking offset cancel ON
Tracking auto gain OK
Focus auto gain OK
Pit
High reflection
CLV-S
CLV LOCK
STOP (CLV: OFF)
Tracking servo ON
Recording mode OFF
CLV normal mode
Tracking offset cancel OFF
Groove
Low reflection
CLV-A
CLV UNLOCK
MEANINGS OF OTHER DISPLAYS
– 26 –
SECTION  5
ELECTRICAL  ADJUSTMENTS
5-1.
PARTS  REPLACEMENT  AND  ADJUSTMENT
• Check and adjust the MDM and MBU as follows.
The procedure changes according to the part replaced
• Abbreviation
OP
: Optical pick-up
OWH : Overwrite head
• Temperature compensation offset check
• Laser power check
• Traverse check
• Focus bias check
• C PLAY check
• Self-recording/playback check
Parts Replacement and Repair
NG
Has the OWH been replaced?
NO
OK
NO
NO
NO
Has OP, IC171, IC101, or 
IC121 been replaced?
YES
YES
Initial setting of the adjustment value
Has OP or IC171 been replaced?
YES
IOP information recording
(IOP value labeled on OP)
Has IC171 or D101 
been replaced?
YES
Temperature compensation offset adjustment
• Laser power adjustment
• Traverse adjustment
• Focus bias adjustment
• Error rate adjustment
• Focus bias check
• Auto gain adjustment
Check the sled and spindle 
mechanisms. 
Other causes can be suspected.
– 27 –
5-2.
PRECAUTIONS FOR CHECKING LASER
DIODE  EMISSINON
To check the emission of the laser diode during adjustments, never
view directly from the top as this may lose your eye-sight.
5-3.
PRECAUTIONS FOR USE OF OPTICAL
PICK-UP (KMS-260A)
As the laser diode in the optical pick-up is easily damaged by static
electricity, solder the laser tap of the flexible board when using it.
Before disconnecting the connector, desolder first. Before con-
necting the connector, be careful not to remove the solder. Also
take adequate measures to prevent damage by static electricity.
Handle the flexible board with care as it breaks easily.
Optical pick-up flexible board
5-4.
PRECAUTIONS FOR ADJUSTMENTS
1. When replacing the following parts, perform the adjustments
and checks with 
¬ in the order shown in the following table.
Optical
Pick-up
BD Board
IC101, IC121
D101
IC171
¬
G
¬
¬
1. Initial setting of
adjustment value
2. Recording of IOP
information
(Value written in
the pick-up)
3. Temperature
compensation
offset adjustment
4. Laser power
adjustment
5. Traverse
adjustment
6. Focus bias
adjustment
7. Error rate check
8. Auto gain output
level adjustment
IC192
G
¬
G
¬
G
G
¬
¬
G
G
G
¬
G
¬
¬
¬
¬
G
¬
¬
G
¬
G
¬
¬
G
¬
G
¬
¬
G
¬
G
¬
¬
G
2. Set the test mode when performing adjustments.
After completing the adjustments, exit the test mode.
Perform the adjustments and checks in “group S” of the test
mode.
3. Perform the adjustments to be needed in the order shown.
4. Use the following tools and measuring devices.
• Check Disc (MD) TDYS-1
(Parts No. 4-963-646-01)
• TEST DISK (MDW-74/AU-1) (Parts No. 8-892-341-41)
• Laser power meter LPM-8001 (Parts No. J-2501-046-A)
or MD Laser power meter 8010S (Parts No. J-2501-145-A)
• Oscilloscope (Measure after performing CAL of prove.)
• Digital voltmeter
• Thermometer
• Jig for checking BD board waveform
(Parts No. : J-2501-149-A)
5. When observing several signals on the oscilloscope, etc.,
make sure that VC and ground do not connect inside the oscil-
loscope.
(VC and ground will become short-circuited.)
6. Using the above jig enables the waveform to be checked with-
out the need to solder.
(Refer to Servicing Notes on page 7.)
7. As the disc used will affect the adjustment results, make sure
that no dusts nor fingerprints are attached to it.
Laser power meter
When performing laser power checks and adjustment (electrical
adjustment), use of the new MD laser power meter 8010S (J-2501-
145-A) instead of the conventional laser power meter is conve-
nient.
It sharply reduces the time and trouble to set the laser power meter
sensor onto the objective lens of the pick-up.
5-5.
CREATING CONTINUOUSLY RECORDED
DISC
* This disc is used in focus bias adjustment and error rate check.
The following describes how to create a continuous recording
disc.
1. Insert a disc (blank disc) commercially available.
A disc is loaded automatically, if pushing the tray.
2. Rotate the 
[        AMS        ]
 knob and display “CREC MODE”.
(C31)
3. Press the 
[YES]
 button again to display “CREC MID”.
Display “CREC (0300)” and start to recording.
4. Complete recording within 5 minutes.
5. Press the 
[MENU/NO]
 button and stop recording .
6. Press the
§ button and remove the disc.
The above has been how to create a continuous recorded data for
the focus bias adjustment and error rate check.
Note :
• Be careful not to apply vibration during continuous recording.
±
pick-up
flexible board
laser tap
– 28 –
5-6.
CHECK  PRIOR  TO  REPAIRS
These checks are performed before replacing parts according to
“approximate specifications” to determine the faulty locations. For
details, refer to “Checks Prior to Parts Replacement and Adjust-
ments” (See page 9).
5-6-1. Temperature Compensation Offset Check
When performing adjustments, set the internal temperature and
room temperature of 22 
°
C to 28 
°
C.
Checking Procedure:
1. Rotate the 
[        AMS        ]
 knob to display “TEMP CHECK”.
2. Press the 
[YES]
 button.
3. “T=@@(##) [OK” should be displayed. If “T=@@ (##) [NG”
is displayed, it means that the results are bad.
(@@ indicates the current value set, and ## indicates the value
written in the non-volatile memory.)
5-6-2. Laser Power Check
Before checking, check the IOP value of the optical pick-up.
(Refer to 5-8. Recording and Displaying the IOP Information.)
Connection :
Checking Procedure:
1. Set the laser power meter on the objective lens of the optical
pick-up. (When it cannot be set properly, press the
0  but-
ton or
) button to move the optical pick-up.)
Connect the digital volt meter to CN110 pin 5 (I + 3V) and
CN110 pin 4 (IOP).
2. Then, rotate the 
[        AMS        ]
 knob and display “LDPWR
CHECK” (C02).
3. Press the 
[YES]
 button once and display “LD 0.9 mW $ 
”.
Check that the reading of the laser power meter become 0.84
to 0.92 mW.
4. Press the 
[YES]
 button once more and display “LD 7.0 mW $
”. Check that the reading the laser power meter and digital
volt meter satisfy the specified value.
Specified Value:
Laser power meter reading: 7.0 ± 0.2 mW
Digital voltmeter reading : Optical pick-up displayed value
±10%
5. Press the 
[MENU/NO]
 button and display “LDPWR CHECK”
and stop the laser emission.
(The 
[MENU/NO]
 button is effective at all times to stop the
laser emission.)
±
[      ]
[      ]
±
Note 1:
After step 4, each time the 
[YES]
 button is pressed, the display
will be switched between “LD 0.7 mW $ 
”, “LD 6.2 mW $
”, and “LD Wp                 $ 
”. Nothing needs to be performed
here.
5-6-3. Traverse Check
Connection :
Checking Procedure:
1. Connect an oscilloscope to CN110 pin 3 (TE) and CN110
pin 1 (VC) of the BD board.
2. Load a disc (any available on the market). (Refer to Note 1.)
A disc is loaded automatically, if pushing the tray.
3. Press the
) button and move the optical pick-up outside
the pit.
4. Rotate the 
[        AMS        ]
 knob and display “EF MO
CHECK”(C03).
5. Press the 
[YES]
 button and display “EFB = 
 MO-R”.
(Laser power READ power/Focus servo ON/tracking servo
OFF/spindle (S) servo ON)
6. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not rotate the
[        AMS        ]
knob.
(Read power traverse checking)
(Traverse Waveform)
7. Press the 
[YES]
 button and display “EFB = 
 MO-W”.
8. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not rotate the 
[        AMS        ]
knob.
(Write power traverse checking)
(Traverse Waveform)
[      ]
±
±
±
+
oscilloscope
(DC range)
10 pF
330 k 
CN110 pin 
3
 (TE)
CN110 pin 
1
 (VC)
BD board
Note 1:
Data will be erased during MO reading if a recorded disc is
used in this adjustment.
Note 2:
If the traverse waveform is not clear, connect the oscilloscope
as shown in the following figure so that it can be seen more
clearly.
Optical pick-up
objective lens
laser
power meter
+
BD board
digital voltmeter
CN110 pin 
5
 (I + 3V)
CN110 pin 
4
 (IOP)
A
B
VC
Specified value : Below 10% offset value
Offset value (%) =                  X 100  
I
A – B
I
2 (A + B)
A
B
VC
Specified value : Below 10% offset value
Offset value (%) =                  X 100  
I
A – B
I
2 (A + B)
+
oscilloscope
(DC range)
V: 0.1 V/div
H: 10 ms/div
BD board
CN110 pin 
3
 (TE)
CN110 pin 
1
 (VC)
KMS260A
27X40
B0825
lOP = 82.5 mA in this case
lOP (mA) = Digital voltmeter reading (mV)/1 (
)
(Optical pick-up label)
(For details of the method for checking
this value, refer to “5-8. Recording and
Displaying the IOP information”.)
Page of 88