– 29 –
9. Press the 
[YES]
 button display “EFB = 
 MO-P”.
Then, the optical pick-up moves to the pit area automatically
and servo is imposed.
10. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not rotate the 
[        AMS        ]
knob.
(Traverse Waveform)
11. Press the 
[YES]
 button display “EF MO CHECK”
The disc stops rotating automatically.
12. Press the
§ button and remove the disc.
13. Load the check disc (MD) TDYS-1.
14. Roteto the 
[        AMS        ]
 knob and display “EF CD CHECK”
(C04).
15. Press the 
[YES]
 button and display “EFB = 
 CD”. Servo is
imposed automatically.
16. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not rotate the 
[        AMS        ]
knob.
(Traverse Waveform)
17. Press the 
[YES]
 button and display “EF CD CHECK”.
18. Press the
§ button and remove the check disc (MD) TDYS-1.
±
±
±
5-6-4. Focus Bias Check
Change the focus bias and check the focus tolerance amount.
Checking Procedure :
1. Load a test disk (MDW-74/AU-1).
A disc is loaded automatically, if pushing the tray.
2. Rotate the 
[        AMS        ]
 knob and display “CPLAY MODE”
(C30).
3. Press the  
[YES]
 button twice and display “CPLAY MID”.
4. Press the 
[MENU/NO]
 button when “C = 
 AD = 
” is
displayed.
5. Rotate the 
[        AMS        ]
 knob and display “FBIAS CHECK”
(C05).
6. Press the 
[YES]
 button and display “
/
 c = 
”.
The first four digits indicate the C1 error rate, the two digits
after [/] indicate ADER, and the 2 digits after [c =] indicate
the focus bias value.
Check that the C1 error is below 220 and ADER is below 2.
7. Press the 
[YES]
 button and display “
/
 b = 
”.
Check that the C1 error is below 220 and ADER is below 2.
8. Press the 
[YES]
 button and display “
/
 a = 
”.
Check that the C1 error is below 220 and ADER is below 2.
9. Press the 
[MENU/NO]
 button, next press the
§ button, and
remove the test disc.
5-6-5. C PLAY Check
MO Error Rate Check
Checking Procedure :
1. Load a test disk (MDW-74/AU-1).
A disc is loaded automatically, if pushing the tray.
2. Rotate the 
[        AMS        ]
 knob and display “CPLAY MODE”
(C30).
3. Press the 
[YES]
 button and display “CPLAY MID”.
4. The display changes to “C = 
 AD = 
”.
5. If the C1 error rate is below 80, check that ADER is below 2.
6. Press the
[MENU/NO]
 button, stop playback, press
the
§ button, and test disc.
CD Error Rate Check
Checking Procedure :
1. Load a check disc (MD) TDYS-1.
A disc is loaded automatically, if pushing the tray.
2. Rotate the 
[        AMS        ]
  knob and display “CPLAY MODE”
(C30).
3. Press the 
[YES]
 button twice and display “CPLAY MID”.
4. The display changes to “C = 
 AD = 
”.
5. Check that the C1 error rate is below 50.
6. Press the
[MENU/NO]
 button, stop playback, press
the
§ button, and the test disc.
5-6-6. Self-Recording/playback Check
Prepare a continuous recording disc using the unit to be repaired
and check the error rate.
Checking Procedure :
1. Insert a recordable disc (blank disc) into the unit.
A disc is loaded automatically, if pushing the tray.
2. Rotate the 
[        AMS        ]
 knob to display “CREC MODE”
(C31).
3. Press the 
[YES]
 button to display the “CREC MID”.
4. When recording starts, “  
REC
  ” is displayed, this becomes
“CREC @@@@” (@@@@ is the address), and recording
starts.
5. About 1 minute later, press the 
[MENU/NO]
 button to stop
continuous recording.
6. Rotate the 
[        AMS        ]
 knob to display “C PLAY
MODE”(C30).
7. Press the 
[YES]
 button to display “C PLAY MID”.
±
±
±
±
±
±
A
B
VC
Specified value : Below 10% offset value
Offset value (%) =                  X 100  
I
A – B I
2 (A + B)
A
B
VC
Specified value : Below 10% offset value
Offset value (%) =                  X 100  
I
A – B I
2 (A + B)
– 30 –
8. “C = 
 AD = 
” will be displayed.
9. Check that the C1 error becomes below 80 and the AD error
below 2.
10. Press the
[MENU/NO]
 button to stop playback, and press
the
§ button and remove the disc.
5-7.
INITIAL  SETTING  OF  ADJUSTMENT  VALUE
Note:
Mode which sets the adjustment results recorded in the non-volatile
memory to the initial setting value. However the results of the tempera-
ture compensation offset adjustment will not change to the initial setting
value.
If initial setting is performed, perform all adjustments again excluding the
temperature compensation offset adjustment.
For details of the initial setting, refer to “5-4. Precautions for Adjustments”
and execute the initial setting before the adjustment as required.
Setting Procedure :
1. Rotate the 
[        AMS        ]
 knob to display “ADJ CLEAR
(C24)”.
2. Press the 
[YES]
 button. “Complete!” will be displayed mo-
mentarily and initial setting will be executed, after which “ADJ
CLEAR” will be displayed.
5-8.
RECORDING  AND  DISPLAYING  THE  IOP
INFORMATION
The IOP data can be recorded in the non-volatile memory. The
IOP value on the label of the optical pickup and the IOP value
after the adjustment will be recorded. Recording these data elimi-
nates the need to read the label on the optical pick-up.
Recording Procedure :
1. While pressing the 
[        AMS        ]
 knob and  
p  button,
connect the power plug to the outlet, and release the
[        AMS        ]
 knob and  
p  button.
2. Rotate the 
[        AMS        ]
 knob to display “[Service]”, and
press the 
[YES]
 button.
3. Rotate the 
[        AMS        ]
 knob to display “Iop.Write” (C28),
and press the 
[YES]
 button.
4. The display becomes Ref=@@@.@ (@ is an arbitrary num-
ber) and the numbers which can be changed will blink.
5. Input the IOP value written on the optical pick-up.
To select the number : Rotate the 
[        AMS        ]
 knob.
To select the digit : Press the 
[        AMS        ]
 knob
6. When the
[YES]
 button is pressed, the display becomes
“Measu=@@@.@” (@ is an arbitrary number).
7. As the adjustment results are recorded for the 6 value. Leave
it as it is and press the 
[YES]
 button.
8. “Complete!” will be displayed momentarily. The value will
be recorded in the non-volatile memory and the display will
become “Iop Write”.
Display Procedure :
1. Rotate the 
[        AMS        ]
 knob to display “Iop.Read”(C27).
2. “@@.@/##.#” is displayed and the recorded contents are dis-
played.
@@.@ indicates the Iop value labeled on the pick-up.
##.# indicates the Iop value after adjustment
3. To end, press the 
[        AMS        ]
 button or 
[MENU/NO]
 button
to display “Iop Read”.
±
[  ]
±
±
±
±
±
±
±
±
5-9.
TEMPERATURE COMPENSATION OFFSET
ADJUTMENT
Save the temperature data at that time in the non-volatile memory
as 25 ˚C reference data.
Note :
1. Usually, do not perform this adjustment.
2. Perform this adjustment in an ambient temperature of 22 ˚C to 28 ˚C.
Perform it immediately after the power is turned on when the internal
temperature of the unit is the same as the ambient temperature of 22 ˚C
to 28 ˚C.
3. When D101 has been replaced, perform this adjustment after the tem-
perature of this part has become the ambient temperature.
Adjusting Procedure :
1. Rotate the 
[        AMS        ]
 knob and display “TEMP ADJUS
(C09)”.
2. Press the  
[YES]
 button and select the “TEMP ADJUS” mode.
3. “TEMP = 
 [OK” and the current temperature data will be
displayed.
4. To save the data, press the 
[YES]
 button.
When not saving the data, press the 
[MENU/NO]
 button.
5. When the 
[YES]
 button is pressed, “TEMP = 
 SAVE” will
be displayed and turned back to “TEMP ADJUS” display then.
When the 
[MENU/NO]
 button is pressed, “TEMP ADJUS” will
be displayed immediatelly.
Specified Value :
The “TEMP =  
” should be within “E0 - EF”, “F0 - FF”, “00 -
0F”,  “10 - 1F” and “20 - 2F”.
5-10. LASER POWER ADJUSTMENT
Check the IOP value of the optical pick-up before adjustments.
(Refer to 5-8. Recording and Displaying the IOP Information.)
Connection :
Adjusting Procedure :
1. Set the laser power meter on the objective lens of the optical
pick-up. (When it cannot be set properly, press the
0 button
or
) button to move the optical pick-up.)
Connect the digital volt meter to CN110 pin 5 (I+3V) and
CN110 pin 4 (IOP).
2. Rotate the 
[        AMS        ]
 knob and display “LDPWR ADJUS”
(C10).
(Laser power : For adjustment)
3. Press the 
[YES]
 button once and display “LD 0.9 mW $ 
”.
4. Rotate the 
[        AMS        ]
 knob so that the reading of the
laser power meter becomes 0.85 to 0.91 mW. Press the 
[YES]
button after setting the range knob of the laser power meter,
and save the adjustment results. (“LD SAVE $ 
” will be
displayed for a moment.)
5. Then “LD 7.0 mW $ 
” will be displayed.
6. Rotate the 
[        AMS        ]
 knob so that the reading of the
laser power meter becomes 6.9 to 7.1 mW, press the 
[YES]
button and save it.
Note:
Do not perform the emission with 7.0 mW more than 15 seconds
continuously.
±
[      ]
[      ]
±
±
±
[  ]
Optical pick-up
objective lens
laser
power meter
+
BD board
digital voltmeter
CN110 pin 
5
 (I + 3V)
CN110 pin 
4
 (IOP)
– 31 –
7. Then, rotate the 
[        AMS        ]
 knob and display “LDPWR
CHECK” (C02).
8. Press the 
[YES]
 button once and display “LD 0.9 mW $ 
”.
Check that the reading of the laser power meter become 0.85
to 0.91 mW.
9. Press the  
[YES]
 button once more and display “LD 7.0 mW $
”. Check that the reading the laser power meter and digital
volt meter satisfy the specified value.
Note down the digital voltmeter reading value.
Specified Value:
Laser power meter reading : 7.0 ± 0.1 mW
Digital voltmeter reading : Optical pick-up displayed value
±10%
10. Press the 
[MENU/NO]
 button and display “LDPWR CHECK”
and stop the laser emission.
(The 
[MENU/NO]
 button is effective at all times to stop the
laser emission.)
11. Rotate the 
[        AMS        ]
 knob to display “Iop.Write”(C28).
12. Press the
[YES]
 button. When the display becomes
Ref=@@@.@ (@ is an arbitrary number), press the 
[YES]
button to display “Measu=@@@.@” (@ is an arbitrary num-
ber).
13. The numbers which can be changed will blink. Input the Iop
value noted down at step 9.
To select the number : Rotate the 
[        AMS        ]
 knob.
To select the digit : Press the 
[        AMS        ]
  knob.
14. When the 
[YES]
 button is pressed, “Complete!” will be dis-
played momentarily. The value will be recorded in the non-
volatile memory and the display will become “Iop Write”.
Note 1:
After step 4, each time the
 [YES] 
button is pressed, the display
will be switched between “LD 0.7 mW $ 
”, “LD 6.2 mW $
”, and “LD Wp               $ 
”. Nothing needs to be performed
here.
±
±
±
±
5-11. TRAVERSE ADJUSTMENT
Connection :
Adjusting Procedure :
1. Connect an oscilloscope to CN110 pin 3 (TE) and CN110
pin 1 (VC) of the BD board.
2. Load a disc (any available on the market). (Refer to Note 1.)
A disc is loaded automatically, if pushing the tray.
3. Press the
) button and move the optical pick-up outside
the pit.
4. Rotate the 
[        AMS        ]
 knob and display “EF MO ADJUS”
(C11).
5. Press the 
[YES]
 button and display “EFB = 
 MO-R”.
(Laser power READ power/Focus servo ON/tracking servo
OFF/spindle (S) servo ON)
6. Rotate the 
[        AMS        ]
 knob so that the waveform of the
oscilloscope becomes the specified value.
(When the 
[        AMS        ]
 knob is rotated, the 
 of “EFB=
” changes and the waveform changes.) In this adjustment,
waveform varies at intervals of approx. 2%. Adjust the wave-
form so that the specified value is satisfied as much as pos-
sible.
(Read power traverse adjustment)
(Traverse Waveform)
7. Press the  
[YES]
  button and save the result of adjustment to
the non-volatile memory (“EFB = 
 SAV” will be displayed
for a moment. Then “EFB = 
 MO-W” will be displayed).
[      ]
±
±
±
+
oscilloscope
(DC range)
10 pF
330 k 
CN110 pin 
3
 (TE)
CN110 pin 
1
 (VC)
BD board
Note 1:
Data will be erased during MO reading if a recorded disc is
used in this adjustment.
Note 2:
If the traverse waveform is not clear, connect the oscilloscope
as shown in the following figure so that it can be seen more
clearly.
(For details of the method for checking
this value, refer to “5-8. Recording and
Displaying the IOP information”.)
KMS260A
27X40
B0825
lOP = 82.5 mA in this case
lOP (mA) = Digital voltmeter reading (mV)/1 (
)
(Optical pick-up label)
+
oscilloscope
(DC range)
V: 0.1 V/div
H: 10 ms/div
BD board
CN110 pin 
3
 (TE)
CN110 pin 
1
 (VC)
A
B
VC
Specification A = B
– 32 –
±
±
8. Rotate the 
[        AMS        ]
 knob so that the waveform of the
oscilloscope becomes the specified value.
(When the 
[        AMS        ]
 knob is rotated, the 
 of “EFB-
” changes and the waveform changes.) In this adjustment,
waveform varies at intervals of approx. 2%. Adjust the wave-
form so that the specified value is satisfied as much as pos-
sible.
(Write power traverse adjustment)
(Traverse Waveform)
9. Press the 
[YES]
 button, and save the adjustment results in the
non-volatile memory. (“EFB = 
 SAV” will be displayed for
a moment.)
10. “EFB = 
 MO-P”. will be displayed.
The optical pick-up moves to the pit area automatically and
servo is imposed.
11. Rotate the 
[        AMS        ]
 knob until the waveform of the
oscilloscope moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
(Traverse Waveform)
12. Press the  
[YES]
 button, and save the adjustment results in the
non-volatile memory. (“EFB = 
 SAV” will be displayed for
a moment.)
Next “EF MO ADJUS” is displayed. The disc stops rotating
automatically.
13. Press the
§ button and remove the disc.
14. Load the check disc (MD) TDYS-1.
A disc is loaded automatically, if pushing the tray.
15. Roteto 
[        AMS        ]
 knob and display “EF CD ADJUS”
(C12).
16. Press the 
[YES]
 button and display “EFB = 
 CD”. Servo is
imposed automatically.
17. Rotate the 
[        AMS        ]
 knob so that the waveform of the
oscilloscope moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
(Traverse Waveform)
±
±
±
18. Press the 
[YES]
 button, display “EFB = 
 SAV” for a mo-
ment and save the adjustment results in the non-volatile
memory.
Next “EF CD ADJUS” will be displayed.
19. Press the
§ button and remove the check disc (MD) TDYS-
1.
5-12. FOCUS BIAS ADJUSTMENT
Adjusting Procedure :
1. Load a test disk (MDW-74/AU-1).
A disc is loaded automatically, if pushing the tray.
2. Rotate the 
[        AMS        ]
 knob and display “CPLAY MODE”
(C30).
3. Press the 
[YES]
 button and display “CPLAY MID”.
4. Press the 
[MENU/NO]
  button when “C = 
 AD = 
” is
displayed.
5. Rotate the 
[        AMS        ]
 knob and display “FBIAS AD-
JUST” (C13).
6. Press the 
[YES]
 button and display “
/
 a = 
”.
The first four digits indicate the C1 error rate, the two digits
after [/] indicate ADER, and the 2 digits after [a =] indicate
the focus bias value.
7. Rotate the 
[        AMS        ]
 knob in the clockwise direction
and find the focus bias value at which the C1 error rate be-
comes 220 (Refer to Note 2).
8. Press the 
[YES]
 button and display “
/
 b = 
”.
9. Rotate the 
[        AMS        ]
 knob in the counterclockwise di-
rection and find the focus bias value at which the C1 error rate
becomes 220.
10. Press the 
[YES]
 button and display “
/
 c = 
”.
11. Check that the C1 error rate is below 50 and ADER is 00.
Then press the 
[YES]
 button.
12. If the “(
)” in “
 - 
 - 
 (
)” is above 20, press the 
[YES]
button.
If below 20, press the 
[MENU/NO]
 button and repeat the ad-
justment from step 2.
13. Press the
§ button to remove the test disc.
Note 1:
The relation between the C1 error and focus bias is as
shown in the following figure. Find points a and b in the follow-
ing figure using the above adjustment. The focal point position
C is automatically calculated from points a and b.
Note 2:
As the C1 error rate changes, perform the adjustment using the
average vale.
±
±
±
±
A
B
VC
Specification A = B
A
B
VC
Specification A = B
A
B
VC
Specification A = B
C1 error
220
b
c
a
Focus bias value
(F. BIAS)
Page of 88
Display