2-18. POWER BOARD
6 POWER board
1 power cord connector
(CN901)
(CN901)
2 screw
(BV3)
(BV3)
2 screw
(BV3)
(BV3)
2 three screws
(BV3)
(BV3)
5 sheet (PS UL) (US, CND)/
sheet (PS) (EXCEPT US, CND)
Insert is shallow
Insert is straight
to the interior.
to the interior.
Insert is incline
connector
connector
connector
connector
NG
OK
NG
connector
connector
Note: When you install the connector, please
install them correctly.
There is a possibility that this machine
damages when not correctly installing it.
3 Remove the
POWER board block
in the direction of
an
arrow.
4 Peel off the
adhesive
adhesive
sheet.
• Abbreviation
CND : Canadian model
CND : Canadian model
HCD-SBT100/SBT100B/SBT300W/SBT300WB
22
2-19. CD MECHANISM DECK BLOCK
2-20. FFC HOLDER
2 CD mechanism deck block
1 two screws
(BV3)
(BV3)
1 two screws
(BV3)
:LUHVHWWLQJ
tape
(sub material)
(sub material)
tape
(sub material)
(sub material)
tape
(sub material)
(sub material)
tape
(sub material)
(sub material)
FFC holder
1 tape
(sub
(sub
material)
1 tape
(sub
(sub
material)
1 tape
(sub
(sub
material)
1 tape
(sub
(sub
material)
boss
boss
claw
2 Remove the
FFC
FFC
holder
in the direction
of an arrow.
3 Draw out the
flexible
flexible
flat
cable
(24P).
–
&'PHFKDQLVPGHFNEORFNERWWRPYLHZ–
4 FFC holder
Note: When installing the FFC holder,
Note: When installing the FFC holder,
check that installed firmly
two bosses and claw.
HCD-SBT100/SBT100B/SBT300W/SBT300WB
23
2-21. OPTICAL PICK-UP (CMS-S76RFS7G/S76RFS7G1/S76RFS7GP) (OP1)
5 insulator
screw
screw
5 insulator screw
5 insulator
screw
screw
5 insulator screw
8 flexible flat cable (24P)
(FFC1)
(FFC1)
9 connector
7 connector
0 insulator
0 insulator
0 insulator
0 insulator
qa optical pick-up (OP1)
Note 1: When you install the connector, please install them correctly.
There is a possibility that this machine damages when not
correctly installing it.
Insert is shallow
Insert is straight
to the interior.
to the interior.
connector
Insert is incline
connector
connector
connector
connector
connector
NG
OK
NG
6 Remove the optical pick-up block
in the direction of an arrow.
4 three
claws
claws
WireVeWWiQJ
1 claw
1 claw
1 claw
1 two
claws
claws
1 claw
2 chuck holder block
3 Draw out the tray.
–B
RWWRPYieZ–
Note 2: When installing the flexible flat cable,
ensure the colored line.
No slanting after insertion.
colored line
colored line
Inserting is straight to the interior.
Inserting is slant.
flexible flat cable
flexible flat cable
connector
connector
OK
NG
Ver. 1.2
HCD-SBT100/SBT100B/SBT300W/SBT300WB
24
SECTION 3
TEST MODE
COLD RESET
It can clears all data including preset data stored in the memory to
initial conditions. Execute this mode when returning the this unit
to the customer.
It can clears all data including preset data stored in the memory to
initial conditions. Execute this mode when returning the this unit
to the customer.
Procedure:
1. Press the [
1. Press the [
?
/
1
] button to turn the power on.
2. Press two buttons of the [
x
] and [
?
/
1
] simultaneously for three
seconds.
3. The message “RESET” (HCD-SBT100/SBT100B) or “ALL
RESET” (HCD-SBT300W/SBT300WB) is displayed on the
fl uorescent indicator tube, then becomes the standby state.
fl uorescent indicator tube, then becomes the standby state.
AUTO STANDBY TEST
It can confi rm the auto standby function operates normally.
The auto standby function operates in 60 seconds in this mode.
(Usually, it takes 30 minutes)
It can confi rm the auto standby function operates normally.
The auto standby function operates in 60 seconds in this mode.
(Usually, it takes 30 minutes)
Procedure:
1. Press the [
1. Press the [
?
/
1
] button to turn the power on.
2. Press the [FUNCTION] button to turn except “FM”, “AM”
and “DAB”.
3. Press two buttons of the [BASS BOOST] and [FUNCTION]
simultaneously for three seconds.
4. It enters the auto standby test mode, and the following screen
is displayed on the fl uorescent indicator tube.
(In this mode, “STEREO” continues blinking on the fl uores-
cent indicator tube)
cent indicator tube)
STEREO
Signal level
(0 or 1)
Countdown
timer
(60 to 0)
Blinking
Screen display
5. In the case of the following states, the countdown timer de-
creases. This unit will become standby states if the countdown
timer decreases to “0”.
timer decreases to “0”.
• Operation is not performed.
• The signal level is lower than threshold.
Releasing method:
Press two buttons of the [BASS BOOST] and [FUNCTION] si-
multaneously for three seconds.
Press two buttons of the [BASS BOOST] and [FUNCTION] si-
multaneously for three seconds.
COMMON TEST
It can confi rm the MAX/MIN of volume.
It can confi rm the MAX/MIN of volume.
Procedure:
1. Press the [
1. Press the [
?
/
1
] button to turn the power on.
2. Press two buttons of the [BASS BOOST] and [
u
] simultane-
ously for three seconds.
3. It enters the common test mode, the message “AUDIO IN” is
displayed on the fl uorescent indicator tube.
(In this mode, “cPLAY” and “SLEEP” continues blinking on
the liquid crystal display)
the liquid crystal display)
Screen display
c
PLAY
SLEEP
Blinking
4. When rotating the [VOLUME] knob, the message is changed
with VOLUME MIN
↔ VOLUME 23 ↔ VOLUME MAX on
the fl uorescent indicator tube.
Screen display
c
PLAY
SLEEP
c
PLAY
SLEEP
c
PLAY
SLEEP
Releasing method:
Press the [
Press the [
?
/
1
] button to turn the power off.
Click on the first or last page to see other HCD-SBT100 / HCD-SBT100B / HCD-SBT300W / HCD-SBT300WB service manuals if exist.