13
HCD-RV660D/RV990D
xxxxhxxm : The laser on total hours. Data below minutes are
omitted.
a.
: Error number.
bb
: Error code.
xx
: Not used.
• Clearing History Information
Clearing laser hours:
Press the  DVD DISPLAY  and  CLEAR  buttons in this order.
Then both CD and DVD data are cleared.
Clearing emergency history:
Press the  DVD TOP MENU  and  CLEAR  buttons in this order.
Initializing set up data:
Press  DVD MENU  and  CLEAR  buttons in this order.
The data have been initialized when “EEPROM Initialize
Finished”  message is displayed.
• Code list of Emergency History
10: Communication to RF amp (IC001) failed.
11: Each servo for focus, tracking, and spindle is unlocked.
12: Check sum error of EEPROM (IC204).
14: Communication to servo DSP (IC509) failed, or servo DSP
(IC509) is faulty.
15: Communication to DVD decoder (IC701) failed, or DVD
decoder (IC701) is faulty.
16: Communication to DSD decoder (IC801) failed, or DSD
decoder (IC801) is faulty. (Not used)
20: Initialization of sled servo failed. It is not placed in the ini-
tial position.
23: Sled servo operation error.
24: Made a request to move the sled servo to wrong position.
30: Tracking balance adjustment error.
31: Tracking gain adjustment error.
33: Focus bias adjustment error.
34: Focus gain adjustment error.
35: Equalizer adjustment error.
40: Focus servo does not operate.
41: With a DVD dual layers disc, focus jump failed.
50: CLV (spindle) servo does not operate.
51: Spindle does not stop.
60: Made a request to seek nonexistent address.
61: Seek error of retry more than regulated times.
70: Control data could not be read.
80: Disc reading failed.
5. MECHA  ERROR  HISTORY
On the Test Mode Menu screen, selecting 
[5]
 displays the information
of mechanism deck error history.
The history information from last 1 up to 8 can be scrolled with
the O button or o button.
### Mecha Error History ###
  1. aa bb cc dd ee xx xx xx
  2. aa bb cc dd ee xx xx xx
  3. aa bb cc dd ee xx xx xx
  4. aa bb cc dd ee xx xx xx
  5. aa bb cc dd ee xx xx xx
  6. aa bb cc dd ee xx xx xx
  7. aa bb cc dd ee xx xx xx
  8. aa bb cc dd ee xx xx xx
Scroll:UP/DOWN
(1.Latest Err.)
Exit: RETURN
aa: Initialization is completed or not.
FF
: Complete.
other number : Not complete.
bb: Operating status of mechanism deck at an error occurred.
(lod sq jcp)
00
: Initializing.
10 to 15 : Open operating.
16 to 19 : Kicking cause open failed.
1A to 1F : Open operating.
20 to 27 : Complete the open operation.
28
: No disc and complete the open operation.
29 to 2F : Complete the open operation.
30 to 3F : Close requesting.
40 to 4F : Open requesting.
50 to 5F : Close operating.
60 to 6F : Complete the chucking operation.
80 to 8F : Complete the release operation.
(BU is home position)
90 to 9F : BU down operating.
A0 to AF : Opening/closing the shutter. Or stationary state in
open/close the shutter is enablement.
B0 to BF : BU up requesting.
C0 to CF : BU down requesting.
D0 to DF : BU upping.
E0 to EF : No disc checking in disc loading.
cc : Operating status of table at an error occurred.
(tbl sq jcp)
13
: The rotation stop position determination error of a table
11 to 12 : The loading position determination error of a table
dd: Operating status of mechanism deck at an error occurred.
(lod op jcp)
00
: Complete the operation.
10 to 1F : Open operating.
20 to 2F : Close operating.
30 to 3F : Release operating.
60 to 6F : Chucking operating.
70 to 7F : Kicking operating.
80 to 8F : Returning the BU to home position. (after kicking)
ee : The status of  table operation. (“n” is unfixed)
(tbl op jcp)
1n : Rotating in the direction of a forward.
2n : Rotating in the direction of a reverse.
14
HCD-RV660D/RV990D
6. VERSION  INFORMATION
On the Test Mode Menu screen, selecting  6  displays the ROM
version and region code.
The parenthesized hexadecimal number in version field is checksum
value of ROM.
## Version Information ##
 IF con.
Ver.x. xx
 SYScon.
Ver.x. xx  (xxxx)
Model
MHC-RVXXXD
Region
0x
Config
xxxxxxxx
 Front End Ver.x.xx
Exit: RETURN
IF con.
: The version of system controller (IC501).
SYScon. : The version of DVD system processor (IC207).
Front End: The version of mechanism controller (IC901).
7. VIDEO  LEVEL  ADJUSTMENT
On the Test Mode Menu screen, selecting  7  displays color bars for
video level adjustment. During display of color bars, OSD disappears
but the menu screen will be restored if pressing the  ENTER  button.
Ver 1.3
3. MECHANICAL ADJUSTMENTS
Precaution
1. Clean the following parts with a denatured alcohol-moistened
swab:
record/playback heads
pinch rollers
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head
demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
Torque Measurement
3.06 N • m to 6.96 N • m
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
0.19 N • m to 0.58 N • m
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
3.06 N • m to 6.96 N • m
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
0.19 N • m to 0.58 N • m
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
6.96 N • m to 14.02 N • m
71 to 143 g • cm
(0.98 – 1.99 oz • inch)
9.80 N • m
100 g or more
(3.53 oz or more)
9.80 N • m
100 g or more
(3.53 oz or more)
Mode
Torque meter
CQ-102C
CQ-102C
CQ-102RC
CQ-102RC
CQ-201B
CQ-403A
CQ-403R
Meter reading
FWD
FWD
back tension
REV
REV
back tension
FF/REW
FWD tension
REV tension
15
HCD-RV660D/RV990D
4. ELECTRICAL ADJUSTMENTS
VIDEO  SECTION
oscilloscope
set
J802
VIDEO OUTPUT
75 
1.00 
±
 0.05 Vp-p
(WHITE 100%)
Note:
1. VIDEO board is basically designed to operate without
adjustment. Therefore, check each item in order given.
2. Use DVD reference disc unless othermise indicated.
[DVD reference disc]
LUV-P01 (CD)
: PART No. 4-999-032-01
TDV-520CSO (DVD-SL) : PART No. J-2501-236-A
TDV-540C (DVD-DL)
: PART No. J-2501-235-A
Note:
 Do not use exiting test disc for DVD.
3. Use an oscilloscope with more than 10M
Ω impedance.
4. Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
AUTO SERVO ADJUSTMENT
After parts related to the servo circuit (RF amplifier (IC001), DSP
(IC509), motor driver (IC501), EEPROM (IC903) so on) are
replaced, re-adjusting the servo circuit is necessary. Select “ALL”
at  “1. DRIVE AUTO ADJUSTMENT” (Refer to page 8 in TEST
MODE) and adjust DVD-SL (single layer), CD and DVD-DL (dual
layer).
Ver 1.3
DECISION TO PASS OR FAIL OF THE OPTICAL
PICK-UP BLOCK
Connection:
Procedure:
1. Connect an oscilloscope to test point pin 1 and pin 3 of CN901
on the DMB03 board.
2. Turn the power on.
3. Put the disc (LUV-P01) (Part No.: 4-999-032-01) (CD) in to
playback.
4. Confirm that oscilloscope waveform is clear and check RF
signal level is correct or not.
5. Put the disc (TDV-520CSO) (Part No.: J-2501-236-A) (DVD) in
to playback.
6. Perform Comfirmation in the same manner as step 4.
Note:
A clear RF signal waveform means that the shape “
◊” can be clearly
distinguished at the center of the waveform.
Video Level Check (VIDEO BOARD)
Purpose
This adjustment is made to satisfy the NTSC standard, and if not
adjusted correctly, the brightness will be too large or small.
Procedure:
1. Connect oscilloscope to VIDEO output.
2. Load a DVD reference disc playback.
3. Check the video signal level is 1.00
±0.05Vp-p.
oscilloscope
+
DMB03 board
CN901 pin 1
CN901 pin 3
CD : 1.05 
±
 0.2 Vp-p
VOLT/DIV : 200 mV 
TIME/DIV : 500 nS
DVD : 1.09 
±
 0.2 Vp-p
RF signal waveform
– DMB03 BOARD (SIDE A) –
CN901
1
7
Checking Location:
16
HCD-RV660D/RV990D
0 dB=0.775 V
DECK  SECTION
1. Demagnetize the record/playback head with a head
demagnetizer.
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjust.
4. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in this
service manual.  (As a general rule, playback circuit adjustment
should be completed before performing recording circuit
adjustment.)
6. The adjustments should be performed for both L-CH and R-
CH.
7. Switches and controls should be set as follows unless otherwise
specified.
• Test Tape
Record/Playback Head Azimuth Adjustment
Note:
 Perform this adjustments for both decks
Procedure:
1. Mode:  Playback
Tape
Signal
Used for
P-4-A063
6.3 kHz, –10 dB
Azimuth Adjustment
DECK A      DECK B
set
MAIN board
IC601
Pin 
wh
 (L-CH)
Pin 
5
 (R-CH)
MAIN board
IC601
Pin 
qk
 (GND)
+
level meter
test tape
P-4-A063
(6.3 kHz, –10 dB)
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3. Mode:  Playback
4. After the adjustments, apply suitable locking compound to the
pats adjusted.
Adjustment Location: Playback Head (Deck A).
Record/Playback/Erase Head (Deck B).
screw
position
L-CH
peak
within
1dB
output
level
L-CH
peak
R-CH
peak
within
1dB
screw
position
R-CH
peak
MAIN
board
IC601
test tape
P-4-A063
(6.3 kHz, –10 dB)
pin 
5
oscilloscope
L-CH
R-CH
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
pin 
qk
pin 
wh
L
R
forward
reverse
Page of 31