Sony DAV-TZ100 / DAV-TZ200 / DAV-TZ300 / HCD-TZ100 / HCD-TZ200 / HCD-TZ300 Service Manual ▷ View online
HCD-TZ100/TZ200/TZ300
17
60: Focus on error
61: Seek fail error
62: Read Q data/ID error
70: Lead in data read fail
71: TOC read time out (CD)
80: Can’t buffering
81: Unknown media type
7-4-1. Clear the Laser Hour
Press [ DISPLAY] button and then press [CLEAR] button on the
remote commander. The data for both CD and DVD data are reset.
Press [ DISPLAY] button and then press [CLEAR] button on the
remote commander. The data for both CD and DVD data are reset.
7-4-2. Clear the Emergency History
Press [DVD TOP MENU] button and then press [CLEAR] button
on the remote commander. The error code for all emergency history
would be reset.
Press [DVD TOP MENU] button and then press [CLEAR] button
on the remote commander. The error code for all emergency history
would be reset.
7-4-3. Clear the Initialize Setup Data
Press [DVD MENU] button and then press [CLEAR] button on the
remote commander.
Press [DVD MENU] button and then press [CLEAR] button on the
remote commander.
7-4-4. Return to the Top Menu of Remocon Diagnosis
Menu
Press [0] button on the remote commander.
7-5. CHECK VERSION INFORMATION
To check the version information, please follow the following
procedure.
To check the version information, please follow the following
procedure.
(1) From the Top Menu of Remocon Diagnosis Menu, select “4.
Version Information” by pressing the [4] button on the remote
commander. The following screen appears on the on-screen
display.
commander. The following screen appears on the on-screen
display.
To return to the Top Menu of Remocon Diagnosis Menu, press
[0] button on the remote commander.
[0] button on the remote commander.
8. AMP TEST MODE
• This mode is used to measurement and test of the AMP con-
nection.
Procedure:
1. Press the [
1. Press the [
?/1
] button to turn the power on.
2. Press three buttons [
x
], [
N
] and [
Z
] simultaneously. When
the this mode, blink to segments (“SA-CD” and “CAT”) on FL
display.
display.
3. Press [DISPLAY] button of the remote commander. When the
this mode is displayed as “MEASURE” on FL display.
Whenever the [DISPLAY] button is pressed, the AMP test
mode changes in the following order.
MEASURE t SAFETY
MEASURE: AMP measurement mode
SAFETY:
SAFETY:
AMP regulations, temperature, character mode
4. Press [MUTING] button on the remote commander. When the
this mode is displayed as “VOL N” on FL display.
Whenever the [MUTING] button is pressed, the VOL test
mode changes in the following order.
VOL N t VOL M/M
VOL N:
Turn the [VOLUME] control, the display is
change in succession (MIN y MAX)
change in succession (MIN y MAX)
VOL M/M: Turn the [VOLUME] control in the direction of
(+) is change to “MIN”, turn the direction of (–)
is change to “MAX”.
is change to “MAX”.
5. To exit from this mode, press the [
?/1
] button to “COLD
RESET” and turn the power off.
Emg. History Check
01. 01 05 04 04
Laser Hours
CD
0h
0min
DVD
0h
0min
00 92 46 00
00 00 00 00
00 00 23 45
02. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
[Next] Next Page [Prev] Prev Page
[O] Return to Top Menu
[O] Return to Top Menu
01. 00 00 00 00
Laser Hours
CD
999h
59min
DVD
999h
59min
00 00 00 00
00 00 00 00
00 00 00 00
02. 00 00 00 00
00 00 00 00
00 00 00 00
00 00 00 00
[Next] Next Page [Prev] Prev Page
[O] Return to Top Menu
[O] Return to Top Menu
Emg. History Check
Emg. History Check
initialize setup data...
Laser Hours
CD
999h
59min
DVD
999h
59min
[Next] Next Page [Prev] Prev Page
[O] Return to Top Menu
[O] Return to Top Menu
Version information
[O] Return to Top Menu
Firm (Main) : Ver. xxxxx
Firm (Sub) : xxxxx
RISC : xxxxx
8032 : xxxxx
Audio DSP : xxxxx
Servo DSP : xxxxx
Firm (Sub) : xxxxx
RISC : xxxxx
8032 : xxxxx
Audio DSP : xxxxx
Servo DSP : xxxxx
Phy,Adr, : F,F,F,F,
HCD-TZ100/TZ200/TZ300
18
9. DEMO PLAY MODE OUT
It is a mode to release the demonstration reproduct by the dedicated
demonstration disc.
1. During playback the DEMO Disc, press the [
It is a mode to release the demonstration reproduct by the dedicated
demonstration disc.
1. During playback the DEMO Disc, press the [
x
] and [
N
]
buttons for fi ve seconds simultaneously.
2. The message “DEMO OFF” is displayed, a mode to reproduct
the demonstration is released.
10. PROTECTION FACTOR (SD DETECTION/
DC DETECTION) IDENTIFICATION TEST MODE
When an error is detected, the FL tube alternately displays
“PROTECTOR h PUSH POWER”.
“PROTECTOR h PUSH POWER”.
r
Press the [
?/1
] button.
* Buttons other than the [
?/1
] button are invalid.
“STANDBY” blinks three times on the FL tube.
r
r
The protection release state (POWER OFF) is established.
(No FL tube display)
r Press the [
(No FL tube display)
r Press the [
?/1
] button two times.
The power to the system turns on, and the normal operation is
established. (Restore)
established. (Restore)
During the protection state:
1. If the AC plug is connected or disconnected during the
1. If the AC plug is connected or disconnected during the
protection state, the protection state is released, and the
normal operation is established. (The protection state is not
maintained.)
normal operation is established. (The protection state is not
maintained.)
2. The protection factor is displayed by pressing the [RETURN]
t [3] t [2] t [0] t [0] t [ANGLE] buttons of the
remote commander.
(during the “PROTECTOR h PUSH POWER” display).
k When SD is detected: Repeats
“SD
DETECT
h PROTECTOR”.
k When DC is detected: Repeats
“DC
DETECT
h PROTECTOR”.
PL: SD detection
When the “L” output from the SD (shutdown) port on the
S-MASTER POWER Driver Shutdown and voltage descent
(15V or less) of 30V power supply (PVDD) are detected.
S-MASTER POWER Driver Shutdown and voltage descent
(15V or less) of 30V power supply (PVDD) are detected.
DC
detection
When the “L” output from the power/speaker error detection
circuit (DC detection port) is detected for two seconds
continually, the power system other than that of the FL tube
is turned off, and the protection state is established.
circuit (DC detection port) is detected for two seconds
continually, the power system other than that of the FL tube
is turned off, and the protection state is established.
HCD-TZ100/TZ200/TZ300
19
SECTION 4
ELECTRICAL ADJUSTMENTS
When the optical pick-up assy is replaced, perform the
“EXECUTING IOP MEASUREMENT”.
“EXECUTING IOP MEASUREMENT”.
EXECUTING IOP MEASUREMENT (See page 15)
[FM Tune Level Check]
Procedure:
1. Turn the power on.
2. Input the following signal from Signal Generator to FM
1. Turn the power on.
2. Input the following signal from Signal Generator to FM
antenna input directly.
* Carrier Freq : A = 87.5 MHz, B = 98 MHz, C = 108 MHz
Deviation : 75 kHz
Modulation : 1 kHz
ANT input : 35 dBu (EMF)
Note: Please use 75 ohm “coaxial cable” to connect SG and the set. You
cannot use video cable for checking.
Please use SG whose output impedance is 75 ohm.
3. Set to FM tuner function and tune A, B and C signals.
4. Confi rm “TUNED” is lit on the display for A, B and C signals.
4. Confi rm “TUNED” is lit on the display for A, B and C signals.
The mark of “TUNED” means “The selected station signal is
received in good condition.”
received in good condition.”
DVD SECTION
TUNER SECTION
generator
OUT (75
:)
SET
FM ANTENNA
HCD-TZ100/TZ200/TZ300
20
MEMO
Click on the first or last page to see other DAV-TZ100 / DAV-TZ200 / DAV-TZ300 / HCD-TZ100 / HCD-TZ200 / HCD-TZ300 service manuals if exist.