HCD-TZ100/TZ200/TZ300
13
2-13. OPTICAL PICK-UP
FFC holder
two insulator screws
two insulator screws
two insulators
two insulators
optical pick-up
(KHM-313CAA)
(KHM-313CAA)
two claws
HCD-TZ100/TZ200/TZ300
14
SECTION 3
TEST MODE
Note: Incorrect operations may be performed if the test mode is not
entered properly.
In this case, press the [?/1] button to turn the power off, and
retry to enter the test mode.
retry to enter the test mode.
1. Cold Reset
• The cold reset clears all data including preset data stored
in the RAM to initial conditions. Execute this mode when
returning the set to the customers.
returning the set to the customers.
Procedure:
1. Press the [
1. Press the [
?/1
] button to turn the power on.
2. Press three buttons [
x
], [
N
] and [
?/1
] simultaneously.
3. When this button is operated, display as “COLD RESET” for
a while and all of the settings are reset.
2. Panel Test Mode
• This mode is used to check the software version, FL and
KEY.
2-1. Display Test Mode
Procedure:
1. Press the [
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press three buttons [
x
], [
.
] and [FUNCTION] simultane-
ously.
3. When the display test mode is activated, all segments are turned
on. When the mode in, lamps of “MOVIE”, “MUSIC” and
“i-ENHANCER” are turn off.
“i-ENHANCER” are turn off.
4. To exit from this mode, press three buttons [
x
], [
.
] and
[FUNCTION] simultaneously.
2-2. Version Test Mode
Procedure:
1. When the display test mode is activated, press the [
Procedure:
1. When the display test mode is activated, press the [
.
] button
and the message “KY0” (TZ100), “KY0” (TZ200), “KY1”
(TZ300) are displayed, the version test mode is activated.
(TZ300) are displayed, the version test mode is activated.
2. Whenever the [
.
] button is pressed, the display changes in
the following order.
“KY0” (Model name) t “ASIA2
*1
” (Destination) t MC Version
*1: ASIA2 changes depending on destination.
3. Press the [
>
] button and the date of the software production
is displayed.
4. Press the [
>
] button again and the version is displayed.
5. To exit from this mode, press three buttons [
x
], [
.
] and
[FUNCTION] simultaneously.
2-3. FL Pattern Test Mode
Procedure:
1. When the display test mode is activated, press the [
Procedure:
1. When the display test mode is activated, press the [
x
] button,
to select the FL pattern test mode. When the FL pattern test
mode, half segments of FL display.
mode, half segments of FL display.
2. Press the [
x
] button, half segments of FL display.
3. Next press the [
x
] button, all segments of FL display is turn
on.
4. To exit from this mode, press three buttons [
x
], [
.
] and
[FUNCTION] simultaneously.
2-4. Key Test Mode
Procedure:
1. When the display test mode is activated, press the [
Procedure:
1. When the display test mode is activated, press the [
N
] button,
to select the key test mode.
2. To enter the KEY test mode, the fl uorescent indicator displays
“K0 V0”. Each time an another button is pressed, “KEY” value
increases. However, once a button is pressed, it is no longer
taken into account. When all keys are pressed correctly, “K9
V0” is displayed.
increases. However, once a button is pressed, it is no longer
taken into account. When all keys are pressed correctly, “K9
V0” is displayed.
3. When the [VOLUME] control is turned in the direction of (+),
“V0” is changed to “V1”, then ... “V9”.
When the [VOLUME] control is turned in the direction of (–),
“V0” is changed to “V9”, then ... “V1”.
“V0” is changed to “V9”, then ... “V1”.
4. To exit from this mode, press three buttons [
x
], [
.
] and
[FUNCTION] simultaneously.
3. Disc Tray Lock
• The disc tray lock function for the antitheft of an demonstra-
tion disc in the store is equipped.
Setting Procedure :
1. Press the [
1. Press the [
?/1
] button to turn the set on.
2. Press the [FUNCTION] button to set DVD function.
3. Insert a disc.
4. Press
3. Insert a disc.
4. Press
the
[
x
] button and the [
Z
] button simultaneously for fi ve
seconds.
5. The message “LOCKED” is displayed and the tray is locked.
Releasing Procedure :
1. Press
Releasing Procedure :
1. Press
the
[
x
] button and the [
Z
] button simultaneously for fi ve
seconds again.
2. The message “UNLOCKED” is displayed and the tray is
unlocked.
Note: When “LOCKED” is displayed, the tray lock is not released by
turning power on/off with the [?/1] button.
4. DVD Ship Mode
• Use this mode when returning the set to the customer after
repair.
Procedure:
1. Press the [
1. Press the [
?/1
] button to turn the set on.
2. Press the [FUNCTION] button to set the function “DVD”.
3. Remove all discs, and then press two buttons [
3. Remove all discs, and then press two buttons [
N
] and [
?/1
]
simultaneously.
4. After a message “MECHA LOCK” h “UNPLUG” is dis-
played on the fl uorescent indicator tube, pull out the AC plug.
5. To exit from this mode, press the [
?/1
] button to turn the set
on.
HCD-TZ100/TZ200/TZ300
15
5. Product Out
• This mode moves the optical pick-up to the position durable
to vibration and clears all data including preset data stored in
the RAM to initial conditions. Use this mode when returning
the set to the customer after repair.
the RAM to initial conditions. Use this mode when returning
the set to the customer after repair.
Procedure:
1. Press the [
1. Press the [
?/1
] button to turn the power on.
2. Press the [FUNCTION] button to set the function “DVD”.
3. Remove all discs, and then press three buttons [
3. Remove all discs, and then press three buttons [
x
], [
Z
] and
[VOLUME+] simultaneously.
4. Displayed to message “initialize all data ...” on the fluorescent
indicator tube when pressing in turn the [4] t [DVD MENU]
t [CLEAR] buttons on the remote commander.
t [CLEAR] buttons on the remote commander.
5. After the “STANDBY” blinking display fi nishes, the message
“MECHA LOCK” h “UNPLUG” is displayed on the
fl uorescent indicator tube disconnect the AC power plug, then
the product out mode is set.
fl uorescent indicator tube disconnect the AC power plug, then
the product out mode is set.
6. Color System Change (Except E32 model)
• Color system change to video signal format (NTSC/PAL).
Procedure:
1. Press the [
1. Press the [
?/1
] button to turn the set on.
2. Press the [FUNCTION] button to set the function “DVD”.
3. Press the [
3. Press the [
?/1
] button to turn the set OFF.
4. Press two buttons [
.
] and [
?/1
] simultaneously, and the
display of fl uorescent indicator tube changes to “COLOR
PAL” or “COLOR NTSC”.
PAL” or “COLOR NTSC”.
DVD SECTION
7-1. GENERAL DESCRIPTION
• The IOP measurement allows you to make diagnosis and ad-
justment simply by using the remote commander and moni-
tor TV. The instructions, diagnosis results, etc. are given on
the on-screen display (OSD).
tor TV. The instructions, diagnosis results, etc. are given on
the on-screen display (OSD).
Be sure to execute the IOP measurement when a BU (Base
Unit) is replaced.
7-2. HOW TO ENTER TEST MODE
While pressing the [
While pressing the [
x
] and [
Z
] buttons simultaneously, turn
[VOLUME] control in the direction of (+) with the DVD player
in power on.
The Test Mode starts, displayed “SERVICE IN” on this model
display then the menu shown below will be displayed on the TV
screen.
* The display of the “Model Name” of the “Remocon Diagnosis
in power on.
The Test Mode starts, displayed “SERVICE IN” on this model
display then the menu shown below will be displayed on the TV
screen.
* The display of the “Model Name” of the “Remocon Diagnosis
Menu” change with the model and the destination. Refer to
below on the model name.
below on the model name.
TZ100
:
KY0
TZ200
:
KY0
TZ300
:
KY1
The menu above is the Remocon Diagnosis Menu screen which
consists of fi ve main functions. At the bottom of the menu screen,
the model name and IF-con version. To exit from the Test Mode,
press the [
consists of fi ve main functions. At the bottom of the menu screen,
the model name and IF-con version. To exit from the Test Mode,
press the [
?/1
] button on the remote commander.
7-3. EXECUTING IOP MEASUREMENT
In order to execute IOP measurement, the following standard pro-
cedures must be followed.
In order to execute IOP measurement, the following standard pro-
cedures must be followed.
(1) In power on, while pressing the [
x
] and [
Z
] buttons simultane-
ously, turn the [VOLUME] control in the direction of (+).
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
Model Name
IF-con
IF-con
: Ver. XX.XX (XXXX)
Syscon
: Ver. X.XXX
: KY0_XX
*
1
*1: Changes depending on destination
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
Model Name
IF-con
IF-con
: Ver. XX.XX (XXXX)
Syscon
: Ver. X.XXX
: KY0_XX
*
1
*1: Changes depending on destination
HCD-TZ100/TZ200/TZ300
16
(2) Select “2. Drive Manual Operation” by pressing the [2] button
on the remote commander. The screen will appear as shown.
(3) Select “3. Manual Adjustment” by pressing the [3] button on
the remote commander. The screen will appear as shown.
(4) Select “6. IOP” by pressing the [6] button on the remote
commander.
(5) Wait until a hexadecimal number appear.
(6) Convert each data from hexadecimal to decimal using
conversion table.
(7) Please fi nd the label on the rear of the BU (Base Unit).
The default IOP value is written in the label.
(8) Subtract between these two values.
(9) If the remainder is smaller than 93 (decimal), then it is
OK. However if the value is higher than 93, then the BU is
defective and need to be change.
defective and need to be change.
(10) Press the [RETURN] button on the remote commander to
return back to previous menu.
(11) Press the [0] button on the remote commander to return to Top
Menu.
7-4. EMERGENCY HISTORY
To check the emergency history, please follow the following
procedure.
To check the emergency history, please follow the following
procedure.
(1) From the Top Menu of Remocon Diagnosis Menu, select “3.
Emergency History Check” by pressing the [3] button on the
remote commander. The following screen appears on the on-
screen display.
remote commander. The following screen appears on the on-
screen display.
(2) You can check the total time when the laser is turned on
during playback of DVD and CD from the above menu. The
maximum time, which can be displayed are 999h 59min.
maximum time, which can be displayed are 999h 59min.
(3) You can check the error code of latest 10 emergency history
from the above menu. To view the previous or next page of
emergency history, press [
emergency history, press [
.
] or [
>
] button on the remote
commander. The error code consists of the following three
blocks. The fi rst block indicates the error code. The second
block indicates the parameter and the third block indicates the
time of error code as shown below.
blocks. The fi rst block indicates the error code. The second
block indicates the parameter and the third block indicates the
time of error code as shown below.
• Error Code
*1 : Error Code
*2 : Parameter of error code
*3 : Time of error code
The meaning of error code is as below:
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mechanical move error (5 Changer)
26: Mechanical move stack error
30: DC motor adjustment error
31: DPD offset adjustment error
32: TE balance adjustment error
33: TE sensor adjustment error
34: TE loop gain adjustment error
35: FE loop gain adjustment error
36: Bad jitter after adjustment
40: Focus NG
42: Focus layer jump NG
51: Spindle stop error
52: Open kick spindle error
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time adjust
0. Return to Top Menu
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time adjust
0. Return to Top Menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
O o Change Value
[RETURN] Return to previous menu
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. 52:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. 52:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
[RETURN] Return to previous menu
O o Change Value
Emg. History Check
01. 01 05 04 04
Laser Hours
CD
999h
59min
DVD
999h
59min
00 92 46 00
00 00 00 00
00 00 23 45
02. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
[Next] Next Page [Prev] Prev Page
[O] Return to Top Menu
[O] Return to Top Menu
Emg. History Check
01. 01 05 04 04
Laser Hours
CD
999h
59min
DVD
999h
59min
00 92 46 00
00 00 00 00
00 00 23 45
02. 02 02 01 01
00 A9 4B 00
00 00 00 00
00 00 23 45
[Next] Next Page [Prev] Prev Page
[O] Return to Top Menu
[O] Return to Top Menu
*
1
*