13
HCD-SE7
• SERVICE POSITION-4 (AMP BOARD)
Extension cable
 (J-2501-077-A)(1.25mm/ 13P/ 300L)
Extension cable
 (J-2501-011-B)(1.25mm/ 19P/ 300L)
MAIN board
AMP board
I/O board
keep here open.
Slant the MAIN board using the two extension cables (19-pins) (J-2501-011-B) and (13-pins) (J-2501-077-A), and check the MAIN board.
14
HCD-SE7
Jig For Checking BD(MD) Board Waveform
The special jig (J-2501-196-A) is useful for checking the waveform of the BD(MD) board. The names of terminals and the checking items to
be performed are shown as follows.
I+3V
: For measuring Iop (Check the deterioration of the optical pick-up laser)
Iop
: For measuring Iop (Check the deterioration of the optical pick-up laser)
GND
: Ground
TE
: TRK error signal (Traverse adjustment)
FE
: Focus error signal
VC
: Reference level for checking the signal
RF
: RF signal (Check jitter)
I+3V
CN105
Iop
TE
VC
GND
FE
RF
I+3V
Iop
GND
TE
FE
VC
RF
I+3V
Iop
GND
TE
FE
VC
RF
1
7
for MDM-7S2D
15
HCD-SE7
Iop DATA RECORDING AND DISPLAY WHEN OPTICAL PICK-UP AND NON-VOLATILE MEMORY (IC195 OF
BD(MD) BOARD) ARE REPLACED
The Iop value labeled on the optical pick-up can be stored in the non-volatile memory. By storing the value, it will eliminate the need to look
at the value on the label of the optical pick-up. When replacing the optical pick-up or non-volatile memory (IC195 of BD(MD) board), store
the Iop value on the optical pick-up according to the following procedure.
Record Precedure:
1. Press the   ?/1  button to turn on the power.
2. Press the [FUNCTION] button to select the “MD” function.
3. While pressing the  MD x  stick and the  FUNCTION  button at the same time, press the  NET MD  button.
4. Press the  > “R”  button stick to display “[Service]”. Then press the  ENTER/YES “R”  button.
5. Press the  > “R”  stick to display “Iop Write” (C05) and press the  ENTER/YES “R”  button.
6. The display becomes “Ref=@@@.@” (@ is an arbitrary number) and the numbers which can be changed will blink.
7. Input the Iop value written on the optical pick-up.
To select the number
: Press the   . “R”  stick or the  > “R”  stick.
To select the digit
: Press the CLOCK/TIMER SET “R” button.
8. When the  ENTER/YES “R”  button is pressed, the display becomes “Measu=@@@.@” (@ is an arbitrary number).
9. As the adjustment results are stored for the 8 value. Leave it as it is and press the  ENTER/YES “R”  button.
10. “Complete!” will be displayed momentarily. The value will be stored in the non-volatile memory and the display will become “Iop
Write” (C05).
11. Press the  REPEAT/FM MODE “R”  button to exit the mode.
12. Press the  ?/1  button to turn off the power. (HCD-SE7)
Display Precedure:
1. Press the  ?/1  button to turn on the power.
2. Press the  FUNCTION  button to select the “MD” function. (HCD-SE7)
3. While pressing the  MD x  stick and the  FUNCTION  button at the same time, press the  NET MD  button.
4. Press the  > “R”  botton stick to display “[Service]”. Then press the  ENTER/YES “R”  button.
5. Press the  > “R”  botton stick to display “Iop Read” (C26) and press the  ENTER/YES “R”  button.
6. “@@.@/##.#” is displayed and the recorded contents are displayed.
@@.@
: indicates the Iop value labeled on the optical pick-up
##.#
: indicates the Iop value after adjustment
7. To end, press the  MENU/NO “R”  button to display “Iop Read” (C26). Then press the  REPEAT/FM MODE “R”  button.
8. Press the  ?/1  button to turn off the power.
Checks Prior to Parts Replacement and Adjustments in MD
Before performing repairs, perform the following checks to determine the faulty locations up to a certain extent.
Details of the procedures are described in “SECTION 5  ELECTRICAL ADJUSTMENTS”.
Note:
The criteria for determination above is intended merely to determine if satisfactory or not, and does not serve as the specified value for adjustments.
When performing adjustments, use the specified values for adjustments.
• 0.93 mW power
Specified value :0.84 to 0.92 mW (KMS-262A)
0.90 to 0.96 mW (KMS-262E)
• 8.65 mW power
Specified value :8.1 to 8.7 mW (KMS-262A)
8.4 to 8.9 mW (KMS-262E)
• Iop (at 8.65 mW)
Labeled on the optical pick-up
Iop value 
±
 10mA
• Unsatisfactory if displayed as “NG : XXXX”(XXXX
are arbitrary numbers)
• Unsatisfactory if displayed as “T=@@ (##) [NG]”
(@@, ## are both arbitrary numbers)
Laser power check
(6-2 : See page 45)
Auto check
(6-4 : See page 46)
Temperature
compensation
offset check
(6-1 : See page 45)
Criteria for Determination
(Unsatisfactory if specified value is not satisfied)
• Clean the optical pick-up
• Adjust again
• Replace the optical pick-up
• Replace the optical pick-up
• Replace the optical pick-up
• Check for disconnection of the circuits around
D101 (BD(MD) board)
• Check the signals around IC101, IC151, CN102,
CN103 (BD(MD) board)
Measure if unsatisfactory
16
HCD-SE7
SECTION 2
GENERAL
This section is extracted
from instruction manual.
Main unit
AM 2 (62, 64)
Disc tray cover qa (12)
DISPLAY 8 (36, 43,  70, 71, 73, 
77)
Display window qs
ENTER/START qg (40)
FM 2 (62, 64)
FUNCTION 5 (11, 34, 35, 36, 
42, 43, 44, 46, 50, 52, 53, 55, 
56, 57, 58, 60, 78, 80)
MD stick 3 (10)
MD slot qh
SYNCHRO MODE qg (40)
NET MD qd (78)
PHONES jack qf
REC MODE qg (39, 42, 43)
REC/REC IT qg (42, 43, 44, 46)
Remote sensor q;
SA-CD/DVD stick 4 (10)
TUNER stick 2 (10)
VOLUME 
+/− 6 (67, 77)
?/1 (power) 1 (9, 38, 48, 68, 
87)
?/1 indicator 9
Z (disc eject) 7 (12)
+/− 2 (62)
x (stop) 34 (13, 29, 34, 40, 77, 
84)
./> (go back/go forward) 
34 (13, 35, 50, 66, 77)
NX (play/pause) 34 (13, 28, 
34, 42, 43)
Z (MD eject) qj (35, 38, 48)
List of button locations and reference pages
How to use this page
Use this page to find the location of buttons and other 
parts of the system that are mentioned in the text.
Illustration number
r
ENTER/START
 qg
 (40)
R
R
Name of button/part
Reference page
ALPHABETICAL ORDER
A - M
N - Z
BUTTON DESCRIPTIONS
1
2 3 4
9
qs
qf
qd
qg
qh qj
6
5
78
qa
q;
Page of 127
Display

Click on the first or last page to see other CMT-SE7 / HCD-SE7 service manuals if exist.