37
•  IC Pin Function Description
USB-AUDIO  BOARD  IC901  LC87F1JJ2AU-SQFP-H (USB  CONTROLLER)
Pin No.
Pin Name
I/O
Description
1
P73
-
Not used
2
XRES
I
Reset signal input from the system controller    “L”: reset
3
XT1
I
Not used
4
XT2
O
Not used
5
VSS1
-
Ground terminal
6
CF1
I
System clock input terminal (12 MHz)
7
CF2
O
System clock output terminal (12 MHz)
8
VDD1
-
Power supply terminal (+3.3V)
9
SO0
O
Serial data output to the CD DSP
10
SI0
I
Serial data input from the CD DSP
11
SCK0
O
Serial data transfer clock signal output to the CD DSP
12
SO1
O
Serial data output terminal    Not used
13
SI1
I
Serial data input terminal    Not used
14
SCK1
O
Serial data transfer clock signal output terminal    Not used
15
P16
O
Chip enable signal output to the CD DSP
16
P17
I/O
Not used
17
MCLKI
I
Master clock signal input terminal    Not used
18
MCLKO
O
Master clock signal output terminal    Not used
19
VDD2
-
Power supply terminal (+3.3V)
20
VSS2
-
Ground terminal
21, 22
P00, P01
I/O
Not used
23 to 25
DBGP0 to DBGP2
-
Debug terminal
26
SDAT
I
Serial data input from the CD DSP
27
BCLK
I
Bit clock signal input from the CD DSP
28
LRCK
I
L/R sampling clock signal input from the CD DSP
29, 30
P20, P21
I/O
Not used
31
P22
O
Audio serial data output to the CD DSP
32
P23
O
Request signal output to the CD DSP
33
P24
O
Audio serial data transfer clock signal output to the CD DSP
34 to 36
P25 to P27
I/O
Not used
37
UHD-
I/O
USB D- serial data input/output terminal
38
UHD+
I/O
USB D+ serial data input/output terminal
39
VDD3
-
Power supply terminal (+3.3V)
40
VSS3
-
Ground terminal
41
UFILT
-
PLL fi lter circuit connection terminal for USB interface    Not used
42
AFILT
-
PLL fi lter circuit connection terminal for audio interface   Not used
43
P32
I/O
Not used
44
URX1
I
USB RX signal input from the system controller
45
UTX1
O
USB TX signal output to the system controller
46
P70
I
Request signal input from the CD DSP
47
P71
I
Sleep control signal input from the system controller
48
P72
I/O
Not used
CDP-CE500
38
MAIN  BOARD  IC301  MB90F831PF-G-SPE1 (SYSTEM  CONTROLLER)
Pin No.
Pin Name
I/O
Description
1
NC
-
Not used
2
TBLL
O
Table motor drive signal (counterclockwise) output to the loading/table motor driver
3
TBLR
O
Table motor drive signal (clockwise) output to the loading/table motor driver
4
LDIN
O
Loading motor drive signal (loading in) output to the loading/table motor driver
5
LDOUT
O
Loading motor drive signal (loading out) output to the loading/table motor driver
6, 7
S2, S1
I
Key input terminal for the BU/table address detect
8
NC
-
Not used 
9
I-RMC (SIRCS)
I
Remote control signal input from the remote control receiver
10
DSEMS
I
Detection signal input from the disc sensor
11
TSENS
I
Detection signal input from the table sensor
12
OUTSW
I
Key input terminal for the open/close detect
13
X0A
I
Sub system clock input terminal    Not used
14
X1A
O
Sub system clock output terminal    Not used
15
VCC
-
Power supply terminal (+3.3V)
16
VSS
-
Ground terminal
17
O-CD-CE
O
Chip enable signal output to the CD DSP
18
O-CD-CL
O
Clock signal output to the CD DSP
19
I-CD-DI
I
Serial data input from the CD DSP
20
O-CD-DO
O
Serial data output for the CD DSP
21, 22
NC
-
Not used 
23
O-CD-M-MUTE
O
CD motor drive on/off mute control signal output to the CD motor/coil driver
24
O-CD-RST
O
System reset signal output to the CD DSP    “L”: reset 
25 to 28
NC
-
Not used
29
I-USB-TXD
I
USB TX signal input from the USB controller
30
O-TP-REC-MUTE
-
Not used
31
O-USB-RXD
O
USB RX signal output to the USB controller
32
AVCC
-
Power supply terminal (+3.3V)
33
O-USB-SLEEP
O
Sleep control signal output to the USB controller
34
O-USB-RST
O
System reset signal output to the USB controller
35
AVSS
-
Ground terminal
36
NC
-
Not used 
37 to 39
I-KEY1 to I-KEY3
I
Front panel key input terminal (A/D input)
40
NC
-
Not used
41
I-KEY-WAKE-UP/VOL
I
Key input terminal for the power
42
I-HOLD
I
Voltage detection signal input from the voltage detector
43
I-VBUS_DET
I
Power supply detection signal input terminal for the VBUS
44
VSS
-
Ground terminal
45
O-XAMUTE
O
Audio muting on/off control signal output terminal
46
I-MODEL
I
Model setting terminal
47
I-SUFFIX
I
Destination x setting terminal 
48
I-ASDMUTE
I
Power monitor signal input terminal 
49, 50
NC
-
Not used
51 to 53
MD2 to MD0
-
Not used
54
I-RST
I
Reset signal input from the reset switch    “L”: reset
55 to 64
NC
-
Not used
65
VCC
-
Power supply terminal (+3.3V)
66
VSS
-
Ground terminal
67 to 80
NC
-
Not used
81
O-PCONT1
O
Power on/off control signal output terminal for the CD section    “H”: power on
82
O-5V-ON
O
Power on/off control signal output terminal for VBUS    “H”: power on
83
O-PCONT0
O
Main power on/off control signal output terminal    “H”: main power on
84, 85
NC
-
Not used
86
O-FL-CS
O
Chip select signal output to the fl uorescent indicator tube driver
87
O-FL-CLK
O
Serial data transfer clock signal output to the fl uorescent indicator tube driver
88
O-FL-DATA
O
Serial data output to the fl uorescent indicator tube driver
89
NC
-
Not used
90
VCC
-
Power supply terminal (+3.3V)
91
VSS
-
Ground terminal
CDP-CE500
39
Pin No.
Pin Name
I/O
Description
92
X1
I
Main system clock input terminal (6 MHz)
93
X0
O
Main system clock output terminal (6 MHz)
94 to 100
NC
-
Not used
40
CDP-CE500
SECTION  6
EXPLODED  VIEWS
  1 
4-198-742-01  PANEL (LOADING 5CDUSB)
  2 
3-363-099-02  SCREW (CASE 3 TP2)
  3 
4-231-686-11  CASE (409538)
  #1 
7-685-646-71  SCREW +BVTP 3X8 TYPE2 IT-3
  Ref. No. 
Part No. 
Description 
Remark
  Ref. No. 
Part No. 
Description 
Remark
6-1.  CASE  SECTION
The components identifi ed by mark 0 
or dotted line with mark 0 are critical for 
safety.
Replace only with part number specifi ed.
Les composants identifi és par une marque 
0 sont critiques pour la sécurité.
Ne les remplacer que par une pièce portant 
le numéro spécifi é.
Note:
•  -XX and -X mean standardized parts, so 
they may have some difference from the 
original one.
•  Items marked “*” are not stocked since 
they are seldom required for routine ser-
vice. Some delay should be anticipated 
when ordering these items.
•  The mechanical parts with no reference 
number in the exploded views are not sup-
plied.
•  Color Indication of Appearance Parts Ex-
ample:
  KNOB, BALANCE (WHITE) . . . (RED)
  
 
↑ 
  
 
Parts Color  Cabinet’s Color
3
not supplied
front panel section
chassis section
2
2
1
#1
#1
Page of 52