HCD-E500W
13
2-10. POWER BOARD
4 three screws (BV3)
5 INCLUDE board
1 connector (CN302)
2 connector (CN301)
3 wire (flat type) (17 core)
(CN300)
2-9. INCLUDE BOARD
5 connector (CN302)
6 four screws
(PWH3
u 8)
4 connector
(CN909)
2 connector (CN904)
1 power cord connector
(CN901)
3 connector (CN906)
9 grass cylindrical fuse (DIA.5) (8A/125V)
(US, Canadian) (F901)
fuse (H.B.C.) (T6.3AH/125V)
(PX)
(F901)
7 five screws
(BV3)
qa POWER board
8 Remove the POWER board
from two PC supports.
0 label fuse (T.H)
(PX)
Ver. 1.1
HCD-E500W
14
SECTION 3
TEST MODE
1. TEST MODES OTHER THAN THE TEST MENU
These are executable test mode even if not entering the test menu.
These are executable test mode even if not entering the test menu.
1-1. Cold Reset
The cold reset clears data except BD/DVD data stored in the RAM
to initial conditions. Execute this mode when returning the set to
the customers.
Procedure:
1. Press the [
The cold reset clears data except BD/DVD data stored in the RAM
to initial conditions. Execute this mode when returning the set to
the customers.
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press the [
x
], [VOLUME –] and [
Z
] buttons simultaneously
and hold down (around 5 seconds).
3. The message “COLD RESET” appears on fl uorescent indica-
tor tube, then becomes standby states.
1-2. AM Step Change
The step interval of AM channels can be toggled between 9 kHz
and 10 kHz.
Procedure:
1. Press the [
The step interval of AM channels can be toggled between 9 kHz
and 10 kHz.
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press the [FUNCTION] button to select the “AM”.
3. Press the [
3. Press the [
N
] and [FUNCTION] buttons simultaneously and
hold down (around 5 seconds).
4. The message “AM 9K STEP” or “AM 10K STEP” appears
on the fluorescent indicator tube, and the AM channel step is
changed.
changed.
1-3. Disc Tray Lock
This mode let you lock the disc tray. When this mode is activated,
the disc will not eject when the [
This mode let you lock the disc tray. When this mode is activated,
the disc will not eject when the [
Z
] button is pressed. The message
“LOCKED” will be displayed on the fluorescent indicator tube.
Procedure:
1. Press the [
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press the [FUNCTION] button to select the “BD/DVD”.
3. Press the [
3. Press the [
x
] and [
Z
] buttons simultaneously and hold down
until “LOCKED” or “UNLOCKED” displayed on the fluores-
cent indicator tube (around 5 seconds).
cent indicator tube (around 5 seconds).
2. TEST MODES IN THE TEST MENU
These are the test modes done in the test menu.
These are the test modes done in the test menu.
Setting method of the test menu:
1. Press the [
1. Press the [
?/1
] button to turn the power on.
2. Press three button in order of the [CLEAR]
→ [
3
]
→ [0] →
[1]
→ [0] → [ANGLE] on the remote commander (Make the
interval when each button is pressed within two seconds).
3. The message “TEST MENU” appears on the fluorescent indi-
cator tube and enter the test menu.
2-1. Panel Test
Procedure:
1. Enter the test menu.
2. Press the [
Procedure:
1. Enter the test menu.
2. Press the [
M
]/[
m
] buttons on the remote commander to select
the “PANEL TEST”, and press the [
3
] button on the remote
commander.
3. LEDs and all segments in fl uorescent indicator tube are lighted
up. And half segments in fl uorescent indicator tube are lighted
up, others half segments in fl uorescent indicator tube are light-
ed up, then LEDs and all segments in fl uorescent indicator tube
are lighted up. This operation is repeated.
up, others half segments in fl uorescent indicator tube are light-
ed up, then LEDs and all segments in fl uorescent indicator tube
are lighted up. This operation is repeated.
4. When all segments in fl uorescent indicator tube are lighted up
in the state of step 3, press the [VOLUME +] button on the
remote commander and model information is displayed on the
fl uorescent indicator tube.
remote commander and model information is displayed on the
fl uorescent indicator tube.
Each time the [VOLUME +] button on the remote commander
is pressed, the display changes from destination information,
MC version, SYS version, UI version, DVD version, ST ver-
sion, TA version, DSP version, TM version, CLA version, CEC
version, SAIR version, DSPF version in this order, and returns
to the model information display.
is pressed, the display changes from destination information,
MC version, SYS version, UI version, DVD version, ST ver-
sion, TA version, DSP version, TM version, CLA version, CEC
version, SAIR version, DSPF version in this order, and returns
to the model information display.
Each time the [VOLUME –] button on the remote commander
is pressed, the version and date are switched.
is pressed, the version and date are switched.
5. In the state of step 3, press the [FUNCTION] button on the
remote commander and “K 0” is displayed on the fluorescent
indicator tube.
indicator tube.
“K 0” value increases whenever a button on the set is pressed
or a sensor is touched. However, once a button has been
pressed, it is no longed taken into account.
or a sensor is touched. However, once a button has been
pressed, it is no longed taken into account.
All buttons on the set are pressed and all sensors are touched,
“OK” and “K 7” are alternately displayed on the fluorescent
indicator tube.
“OK” and “K 7” are alternately displayed on the fluorescent
indicator tube.
6. To release from this mode, press the [
?/1
] button.
2-2. AMP Test
Procedure:
1. Enter the test menu.
2. Press the [
Procedure:
1. Enter the test menu.
2. Press the [
M
]/[
m
] buttons on the remote commander to select
the “AMP TEST”, and press the [
3
] button on the remote
commander.
3. The message “MEASURE” appears on the fluorescent indica-
tor tube and enter the AMP test mode.
4. Press the [BLUE] button on the remote commander, the state
of D.C.A.C. microphone is displayed on the fl uorescent indica-
tor tube.
tor tube.
“D.C.A.C M. IN” : D.C.A.C. microphone on (Microphone
detection)
“D.C.A.C M. OUT” : D.C.A.C. microphone on (Microphone
non-detection)
“FUNC INPUT”
: D.C.A.C. microphone off
5. Press the [MUTING] button on the remote commander, “VOL-
UME MIN/NORMAL/MAX” can be switched.
6. Press the [SUBTITLE] button on the remote commander, the
message “VACS ON” or “VACS OFF” appears on the fl uores-
cent indicator tube and thus the VACS on/off are changed.
cent indicator tube and thus the VACS on/off are changed.
7. To release from this mode, press the [
?/1
] button.
HCD-E500W
15
2-3. Cold Reset
The cold reset clears data except BD/DVD data stored in the RAM
to initial conditions. Execute this mode when returning the set to
the customers.
Procedure:
1. Enter the test menu.
2. Press the [+] buttons on the remote commander to select the
The cold reset clears data except BD/DVD data stored in the RAM
to initial conditions. Execute this mode when returning the set to
the customers.
Procedure:
1. Enter the test menu.
2. Press the [+] buttons on the remote commander to select the
“COLD RESET”, and press the [
3
] button on the remote com-
mander.
3. The message “COLD RESET” appears on the fluorescent indi-
cator tube, then becomes standby states.
2-4. BD Service
This mode describes details in “3. BD SERVICE MODE” (page
16).
This mode describes details in “3. BD SERVICE MODE” (page
16).
2-5. Tuner Factory Preset
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-6. Digital Media Port Test
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-7. Test Tone Mode
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-8. VACS Display
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-9. VACS On/off
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-10. DSP Halt Mode
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-11. DSP Status Display
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-12. A.CAL Test Disp
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-13. Sircs
Disable
Not used for the servicing.
Press the [
Press the [
?/1
] button if having entered this mode.
2-14. DMPORT Device Test
Procedure:
1. Connect the DMPORT device to this set.
2. Enter the test menu.
3. Press the [
Procedure:
1. Connect the DMPORT device to this set.
2. Enter the test menu.
3. Press the [
M
]/[
m
] buttons on the remote commander to select
the “DMPORT TEST”, and press the [
3
] button on the remote
commander.
4. The DMPORT device enter to the test mode. The operation of
the test mode is different according to each device.
Example of connecting TDM-iP20:
When it enters the test mode and some button operations are
done, the software version is displayed by blinking LED.
done, the software version is displayed by blinking LED.
X . X X: software version
second digit of minor version
fi rst digit of minor version
major
version
LED blinks every 0.2 seconds, and LED is turned off for 0.7
seconds afterwards. The blinking frequency at this time shows
the majors version.
seconds afterwards. The blinking frequency at this time shows
the majors version.
Next, LED blinks every 0.2 seconds, and LED is turned off
for 0.7 seconds afterwards. The blinking frequency at this time
shows the fi rst digit of minor version.
for 0.7 seconds afterwards. The blinking frequency at this time
shows the fi rst digit of minor version.
Next, LED blinks every 0.2 seconds, and LED is turned off
for 0.7 seconds afterwards. The blinking frequency at this time
shows the second digit of minor version.
for 0.7 seconds afterwards. The blinking frequency at this time
shows the second digit of minor version.
Then, it returns to the state that LED blinks.
5. To release from this mode, press the [
?/1
] button.
2-15. S-AIR Test Mode
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-16. S-AIR Radio Mode
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-17. S-AIR ID Change Mode
Procedure:
1. Install a wireless transceiver in this set, and communicate with
Procedure:
1. Install a wireless transceiver in this set, and communicate with
the device for the S-AIR communication.
2. Enter the test menu.
3. Press the [
3. Press the [
M
]/[
m
] buttons on the remote commander to select
the “SAIR ID”, and press the [
3
] button on the remote com-
mander.
4. The S-AIR ID is changed, and release from the test menu.
Note: Changed S-AIR ID is returned to S-AIR ID set at once with the [S-
AIR ID] switch of this set.
2-18. EXTRACT ID Mode
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-19. DMPORT Read Mode
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-20. DMPORT Write Mode
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-21. S-Master Setting Switch Mode
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
HCD-E500W
16
2-22. Parental Reset Mode
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-23. CD Repeat Mode
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-24. S-AIR Delay Mode
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-25. DSP Sampling Frequency Display Mode
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-26. Power Handling Mode 1
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-27. Power Handling Mode 2
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-28. Repeat Status Display Mode
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
3. BD SERVICE MODE
Note 1: The operation in this mode must use a remote commander.
Note 2: Connect the monitor with this set with the HDMI cable when you
Note 2: Connect the monitor with this set with the HDMI cable when you
execute this mode. This mode cannot be executed when connect-
ing it with CVBS and COMPONENT.
ing it with CVBS and COMPONENT.
Setting method of the BD service mode:
1. Press the [
1. Press the [
?/1
] button to turn the power on.
2. Press three button in order of the [CLEAR]
→ [
3
]
→ [0] →
[1]
→ [0] → [ANGLE] on the remote commander. (Make the
interval when each button is pressed within two seconds)
3. The message “TEST MENU” appears on the fluorescent indi-
cator tube and enter the test menu.
4. Press the [
M
]/[
m
] buttons on the remote commander to select
the “SERVICE IN”, and press the [
3
] button on the remote
commander.
5. Enter the BD service mode.
3-1. Main Functions
• ErrorLog/CommandLog
• ErrorLog/CommandLog
display
Display the error log and command log. Displayed contents
can also be saved in an USB memory device.
can also be saved in an USB memory device.
• Diag
Performs unit test of devices installed on the board.
• Factory
Initialize
Restores the set to its factory settings.
• Network
Checks the network connection.
1. “Ifconfig” displays the network settings of the unit.
1. “Ifconfig” displays the network settings of the unit.
Executing this function will run the #Ifconfig command
and display the result.
and display the result.
2. “Ping” checks the communication status between the net-
work and terminal of the specified IP address.
Executing this function will run the #ping command and
display the result.
display the result.
• Version Up (version update)
Performs version update using a disc. For details concerning
updates, see the attached reference.
updates, see the attached reference.
• Ststem
Information
Displays the system information of the set.
Displays information such as the software version, drive infor-
mation, etc.
mation, etc.