LC-26SH330, LC-32SH330, LC-42SH330 
 37 
14 
   
15 
   
16 
   
17 
   
Input Block(have 
sub page) 
(Source list..) 
(TV,YPbPr,AV,SCART,PC,HDMI) 
   
   
Set password 
(have sub page) 
New Password (xxxx) 
   
   
Confirm Password (xxxx) 
   
   
Clear All 
   
   
   
Eco 
Eco 
Off 
   
   
   
On 
   
   
   
 
LC-26SH330, LC-32SH330, LC-42SH330 
38  
2. Display adjustment  
 
  
YPbPr Mode display adjustment 
 
1) Auto color for signal slicering 
 
 
General set-up : 
Equipment Requirements: Minolta CA-110 or Equivalent Color analyzer, Quantum Data Pattern Generator 802G , 802BT or equivalent instrument 
Input requirements: 
Input Signal Type: YPbPr signal 
1>. 1080i/25mode, TVBar100 pattern by 802G or 802BT. 
2>. Select Picture mode to User mode and check the x, y data.  
Input Signal Strength : 1 Vpp  for Y signal ; 700 mVpp for Pb & Pr signal 
Input Injection Point  : YPbPr (RAC jack) 
 
1080i/25, TVBar100 pattern 
 
Alignment method: 
Initial Set-up:  
1>. Select source as “YPbPr”. 
2>. Set Smart Picture mode as “Personal” and then adjust Contrast = 58,  Brightness=48, Color=58, set Color Temp. to be “cool” mode. 
3>. Apply “TVBar100” pattern which is color bar pattern by signal generator.                       
4>. Enter “factory mode menu”: press MENU + Numeric keys “1999”  
Alignment:  
1>. At factory mode menu, select AUTO_COLOR item. Then press “OK” key of remote control to adjust ADC_GAIN_R, ADC_GAIN_G, 
ADC_GAIN_B and ADC_OFFSET_R, ADC_OFFSET_G, ADC_OFFSET_B. Then store those values to NVM. 
2>.  Check the 16 grayscale pattern should be distinguished and color bar is correct 
3>. Reset AV setting, picture mode shall be recalled to be “Vivid” and Contrast=58, Brightness=48; Color=58. 
                        
2) White balance adjustment
 
 
Alignment method: 
Initial Set-up:  
1>. Select source as “YPbPr”. 
2>. Set Contrast = 58 and Brightness=48, Color=58, at normal menu mode. 
3>. Apply “80% white pattern or Flat 80 pattern” by Component video generator.                        
4>. Enter factory mode menu: press MENU + Numeric keys 1999. 
Alignment:  
1>. Apply Flat80 pattern (80% white pattern). 
2>. Set color temperature to “NORMAL”. 
3>. At factory mode menu, adjust the CLR TEMP R, CLR TEMP G,  CLR TEMP B values to meet “NORMAL” color coordinates specification below. 
         2008-03-14 
LC-26SH330, LC-32SH330, LC-42SH330 
 39 
Then store those values to NVM 
4>. Set color temperature to “COOL”. 
5>. At factory mode menu, adjust the CLR TEMP R, CLR TEMP G,  CLR TEMP B values to meet “COOL” color coordinates specification below. 
Then store those values to NVM 
6>. Set color temperature to “WARM”. 
7>. At factory mode menu, adjust the CLR TEMP R, CLR TEMP G,  CLR TEMP B values to meet “WARM” color coordinates specification below. 
Then store those values to NVM 
Color temperature Normal/Warm/Cool (x, y) co-ordinates specification: 
   
                                  
 
Reading with Minolta CA-210. 
Note:  
1>. Use Minolta CA-210 for color coordinates and luminance check. 
2>. Before adjusting, all colour analyzers (CA-210) should be coordinates with a same reference TV set. 
3>. Check the luminance in the center of the screen with 100% White  when Brightness control at 100; Contrast control at 100  
Luminance > 350 cd/m
2
      << For 26” only at color temp.- cool mode >>                
  
360 cd/m
2
      << For 32” only at color temp.- cool mode >>
    
 
  
   > 320 cd/m
2
      << For 42” only at color temp.- cool mode >> 
 
PC mode display adjustment 
 
1) Auto color for signal slicering 
 
General set-up : 
Equipment Requirements: Minolta CA-210 or Equivalent Color analyzer, Chroma 2250 or equivalent PC signal generator 
Input requirements: 
Input Signal Type      : PC VGA signal 
1>. 1024X768/60Hz PC mode with “5 white block” pattern. (see pattern-1)                                                                                                                                      
Input Signal Strength : 0.7 Vp-p linear voltage. 
Input Injection Point  : PC D-SUB input 
 
Pattern-1 
Alignment method: 
Initial Set-up:  
1>. Select source as “PC”. 
2>. Set Contrast = 50 (Sharp) and Brightness=100 (Sharp) , at normal menu mode. 
3>. Apply “5 white block”(pattern-1) pattern by VGA pattern generator.                        
4>. Enter factory mode menu: press MENU + Numeric keys “1999” (factory mode menu).  
Alignment:  
1>. At factory mode menu, select AUTO_COLOR item. Then press “OK” key to adjust ADC_GAIN_R, ADC_GAIN_G, ADC_GAIN_B and 
ADC_OFFSET_R, ADC_OFFSET_G, ADC_OFFSET_B. Then store those values to NVM. 
Picture Mode 
Normal (9000
o
K) 0.289±0.003 
0.291±0.003 
Cool (12000
o
K) 0.272±0.003 
0.277±0.003 
Warm (6500
o
K) 0.314±0.003 
0.319±0.003 
LC-26SH330, LC-32SH330, LC-42SH330 
40  
Set Contrast = 100 (Sharp) and Brightness=100 (Sharp) 
Check color temperature specification with PC mode. 
Color temperature Normal/Warm/Cool (x, y) co-ordinates specification: 
   
  
 
Reading with Minolta CA-210. 
Note:  
1. Use Minolta CA-210 for color coordinates and luminance check. 
2. Befor checking,all colour analyzers (CA-210) should be coordinates with a same reference TV set. The RGB Gain should not exceed 128 when 
adjust the white balance 
3. Check the luminance in the center of the screen with 100% White  when Brightness control at 100; Contrast control at 100  
Luminance > 350 cd/m
2
      << For 26” only at color temp.- cool mode >>                
  
360 cd/m
2
      << For 32” only at color temp.- cool mode >>
    
 
  
    >320 cd/m
2
      << For 42” only at color temp.- cool mode >> 
 
3. Factory mode preset
 
Default Values 
 
    
      
   
    
Item 
Setting 
Remark 
BRAND 
Sharp 2K9 EU 
 
Date 
APR 28 2009 
 
Ver Vx.xx   
Model name 
LC-26SH330 
For 26” 
 LC-32SH330 
For 
32” 
 LC-42SH330 
For 
42” 
Scaler MT5363   
Tuner Type 
NXP FH2607 
LG TDTW-S810D 
 
Panel Type 
T260XW04 V7: AUO 
For 26” 
 
T315XW04 V1: AUO 
For 32” 
 
T420HW09 V0: AUO 
For 42” 
Current source 
xxxx 
 
 
Item 
Setting 
Remark 
Auto color 
No 
 
 YPbPr 
PC 
mode   
ADC R gain 
128 
128 
 
ADC G gain 
128 
128 
 
ADC B gain 
128 
128 
 
ADC R Offset 
128 
128 
 
ADC G Offset 
128 
128 
 
ADC B Offset 
128 
128 
 
Note: These above values will be changed after doing “AUTO_COLOR” at FAC mode menu. 
 
Item 
Setting 
Remark 
Color Temp 
Normal 
 
 Cool 
Normal 
Warm   
Scaler R Gain 
128 
128 
128 
 
Scaler G Gain 
128 
128 
128 
 
Scaler B Gain 
128 
128 
128 
 
Scaler R Offset 
128 
128 
128 
 
Scaler G Offset 
128 
128 
128 
 
Scaler B Offset 
128 
128 
128 
 
Note: These above values will be changed after doing “White-D Alignment” at FAC mode menu. 
 The alignment is doing in the YPbPr mode. 
 
Item 
Setting 
Remark 
Burn in 
No 
 
Picture Mode 
Normal (9000
o
K) 0.289±0.015 
0.291±0.015 
Cool (12000
o
K) 0.272±0.010 
0.277±0.010 
Warm (6500
o
K) 0.314±0.015 
0.319±0.015 
Page of 127