MX-M565N  ADJUSTMENTS AND SETTINGS  4 – 3
3. Details of adjustment
 
ADJ 1
Adjust the developing unit
 
1-A
Adjust the developing doctor gap
This adjustment is needed in the following situations:
* The developing unit has been disassembled.
* When the print image density is low.
* When there is a blur on the print image.
* When there is unevenness in the print image density.
* The toner is excessively dispersed.
NOTE: Be careful not to put fingerprints, oil, grease, or foreign
materials on the roller during the work.
NOTE: Do not hold the adjacent section of the MG roller strongly.
1)
Remove the developing unit from the main unit, and remove
the developing unit upper cover.
NOTE: All DV material must be removed before beginning step 2.
2)
Loosen the developing doctor fixing screw.
3)
Insert a thickness gauge of 0.675mm in between 20mm -
40mm from the edge of the developing doctor.
4)
Push the developing doctor in the arrow direction, and tighten
the fixing screw of the developing doctor. (Perform the similar
procedure for the front frame and the rear frame.)
5)
Check that the doctor gaps at two positions in 20mm - 40mm
from the both sides of the developing doctor are in the range of
0.675   0.025mm.
* When inserting a thickness gauge, be careful not to scratch the
developing doctor and the developing roller.
Note for use of a thickness gauge
* Do not insert the gauge diagonally.
* The gauge must pass freely.
* The advisable point of measurement is the MIN point of the MG
roller oscillation.
 
1-B
Adjust the developing roller main pole 
position
This adjustment is needed in the following situations:
* The developing unit has been disassembled.
* When the print image density is low.
* When there is a blur on the print image.
* When there is unevenness in the print image density.
* The toner is excessively dispersed.
NOTE: Be careful not to put fingerprints, oil, grease, or foreign
materials on the roller during the work.
1)
Remove the developing doctor cover, and place the develop-
ing unit on a flat surface.
NOTE: All DV material must be removed before beginning step 2.
2)
Attach a piece of string to a sewing needle or pin.
3)
Hold the thread and bring the needle near the developing
roller. (Do not use a paper clip because too heavy. It will not
provide a correct position.)
4)
Mark the developing roller surface on the extension line of the
needle with the needle at 2 - 3mm from the developing roller
surface. (Never touch the needle tip with the developing roller.)
20mm
40mm
20mm
40mm
2~3mm
MX-M565N  ADJUSTMENTS AND SETTINGS  4 – 4
5)
Measure the distance between the marking position and the
doctor tip of the developing unit, and check that it is 11.0 
0.5mm.
If the distance is not within the above range, adjust the devel-
oping roller main pole position in the following procedures.
6)
Remove the developing unit front cover, loosen the fixing
screw of the developing roller main pole adjustment plate, and
move the adjustment plate in the arrow direction to adjust.
Repeat procedures 3) - 6) until the developing roller main pole
position comes to the specified range.
7)
After completion of the adjustment of the developing roller
main pole position, fix the developing roller main pole adjust-
ment plate with the fixing screw.
 
1-C
Toner density control reference value 
setting
This adjustment is needed in the following situations:
* When developer is replaced.
NOTE: Be sure to execute this adjustment only when developer is
replaced. Never execute it in the other cases.
1)
With the front cabinet open, enter SIM 25-2.
When setting the toner density control reference value, pull out
the toner cartridge in advance.
2)
Close the front cabinet and press [EXECUTE] button.
11.0±0.5mm
 
   S I MU L A TI O N   NO . 25 - 0 2
    
0
T E S T
C L OS E
A T  D EV E   AD J _L _ K            :        1 28
A T  D EV E   AD J _M _ K            :        1 28
A T  D EV E   VO _ L_ K              :        1 28
A T  D EV E   VO _ M_ K              :        1 28
A U TO M AT I C  D E VE L OP E R  A D JU S TM E N T
E X EC U TE
1 / 1
K
10 K EY
1 0K E Y
1 0K E Y
10 K EY
1 0K E Y
1 0K E Y
10 K EY
1 0K E Y
1 0K E Y
10 K EY
1 0K E Y
1 0K E Y
10 K EY
10 K EY
1 0 KE Y
4
5
6
1
2
3
7
8
9
*
0
#
B A C K
S T AR T
EX I T
C LE A R
Adjustment completed 
Abnormal end 
    SI M U LA T IO N   N O. 2 5 -0 2
     
0
TE S T
CL O S E
T C S_ K                              :         4 5
T S G_ K                              :         4 5
AU T OM A TI C   DE V EL O PE R   AD J US T M EN T
EX E CU T E
1 /1
K
1 0 KE Y
1 0 KE Y
1 0 K EY
1 0 KE Y
1 0 KE Y
1 0 K EY
1 0 KE Y
1 0 KE Y
1 0 K EY
1 0 KE Y
1 0 KE Y
1 0 K EY
1 0 KE Y
1 0 KE Y
10 K E Y
4
5
6
1
2
3
7
8
9
*
0
#
B AC K
ST A R T
E X IT
C L E AR
   S I MU L AT I O N  N O . 25 - 02
    
0
T E ST
C L OS E
AT   D EV E  A D J _L _ K            :        12 8
AT   D EV E  A D J _M _ K            :        12 8
AT   D EV E  V O _ L_ K              :        12 8
AT   D EV E  V O _ M_ K              :        12 8
A UT O MA T I C  D EV E LO P E R  A DJ U S TM E NT
E XE C UT E
1 / 1
K
1 0 K EY
10 K E Y
10 K E Y
10 K EY
10 K E Y
10 K E Y
10 K EY
10 K E Y
10 K E Y
10 K EY
10 K E Y
10 K E Y
10 K EY
1 0 K EY
1 0 KE Y
4
5
6
1
2
3
7
8
9
*
0
#
B A CK
S TA R T
EX I T
C LE A R
   S IM U LA T I ON   N O .2 5 -0 2
    
0
T ES T
C LO S E
TC S _K                              :         E E -E L
TS G _K                              :         4 5
AU T O MA T IC   DE V E LO P ER   AD J U ST M EN T
EX E C UT E
1 /1
K
1 0 KE Y
10 K EY
10 K EY
1 0 KE Y
10 K EY
10 K EY
1 0 KE Y
10 K EY
10 K EY
1 0 KE Y
10 K EY
10 K EY
1 0 KE Y
1 0 KE Y
1 0K E Y
4
5
6
1
2
3
7
8
9
*
0
#
B A CK
S TA R T
E X I T
CL E AR
MX-M565N  ADJUSTMENTS AND SETTINGS  4 – 5
3)
After completion of the adjustment of the toner density control
reference value, insert the toner cartridge.
4)
Close the front cabinet.
5)
When [EXECUTE] key is pressed, it is highlighted. The devel-
oping roller rotates, and the toner density sensor detects toner
density, and the output value is displayed. The above opera-
tion is executed for 2 minutes, and the average value of the
toner density sensor detection level is set (saved) as the refer-
ence toner density control value. When the reference toner
density control adjustment operation is completed, [EXE-
CUTE] key returns to normal from highlight. This makes known
about whether the adjustment operation is completed or not.
NOTE:
If the operation is interrupted within 2 minutes, the adjustment
result is not reflected. When [EXECUTE] key is pressed during
rotation, the operation is stopped and [EXECUTE] key returns
to the normal display. If [EE-EU], [EE-EL] or [EE-EC] is dis-
played, setting of the reference toner density control value is
not completed normally.
NOTE: When not replacing the developer, do not execute SIM25-
2.
 
ADJ 2
Adjusting high voltage values
 
2-A
Adjust the main charger grid voltage
This adjustment is needed in the following situations:
* When the high voltage PWB is replaced.
* U2 trouble has occurred.
* The PCU PWB has been replaced.
* The EEPROM of the PCU PWB has been replaced.
1)
Enter the SIM 8-2 mode.
2)
Select an output mode and an item to be adjusted.
3)
Enter the adjustment value (specified value) in the middle
speed mode and press [OK] key.
Enter the adjustment value of each mode which is specified on
the label attached on the high voltage power PWB.
GBK: XXX
The default value s specified for each model must be changed
as follows. 46cpm/56cpm machine: +5
Note that the adjustment value may differ depending on the high
voltage power PWB. Since the adjustment value label is attached
on the high voltage PWB, the PWB must be removed in order to
check the adjustment value. This is a troublesome procedure.
Therefore, it is advisable to put down the adjustment value in
advance. When the adjustment value (specified value) of the mid-
dle speed mode is set, the adjustment values of the other modes
are automatically set according to the middle speed mode setting in
a certain relationship.
Since the high voltage output cannot be checked with a digital multi
meter in this model, a judgment of the output must be made by
checking the print image quality.
Error display
Content
Details of content
EE-EL
EL abnormality
Sensor output level less than 77, or 
sensor control voltage level over 207
EE-EU
EU abnormality
Sensor output level over 177, or sensor 
control voltage level less than 52
EE-EC
EC abnormality
Sensor output level less than 125, or 
sensor control voltage level over 131
 
EXECUTE 
EXECUTE 
or  after 30 sec 
10 key 
   S I MU L A TI O N   NO . 08 - 0 2
   
 0
T E S T
C L OS E
:  M ID D LE   S PE E D  G B_ K
M H V/ G RI D  S E T TI N G  A ND   O UT P UT
50 0
A
[ 1 5 0  ~  8 50   ]
A:  5 0 0
O K
E X EC U TE
M I DD L E
LO W
10 K EY
1 0K E Y
1 0K E Y
10 K EY
1 0K E Y
1 0K E Y
10 K EY
1 0K E Y
1 0K E Y
10 K EY
1 0K E Y
1 0K E Y
10 K EY
10 K EY
1 0 KE Y
4
5
6
1
2
3
7
8
9
*
0
#
B A C K
S T AR T
EX I T
C LE A R
   S I MU L A TI O N   NO . 08 - 0 2
   
 0
T E S T
C L O SE
:  M ID D LE   S PE E D  G B _K
M H V/ G RI D  S E T TI N G  A N D  O UT P UT
64 5
A
[ 1 5 0  ~  8 50   ]
A:  6 4 5
O K
E X EC U TE
M I DD L E
LO W
10 K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
10 K E Y
1 0 K EY
4
5
6
1
2
3
7
8
9
*
0
#
BA C K
S T AR T
E XI T
C L EA R
Item/Display
Content
Setting 
range
Actual voltage
36
46
56
MID
DLE
A
MIDDLE 
SPEED 
GB_K
Charging/grid 
bias set value
150 - 
850
-665V 
±5V
-670V 
±5V
-
670V 
±5V
LO
W
A
LOW 
SPEED 
GB_K 
Charging/grid 
bias set value
150 - 
850
-665V 
±5V
-665V 
±5V
-665V 
±5V
MX-M565N  ADJUSTMENTS AND SETTINGS  4 – 6
 
2-B
Adjust the developing bias voltage
This adjustment is needed in the following situations:
* When the high voltage PWB is replaced.
* U2 trouble has occurred.
* The PCU PWB has been replaced.
* The EEPROM of the PCU PWB has been replaced.
1)
Enter the SIM 8-1 mode.
2)
Select an output mode and an item to be adjusted.
3)
Enter the adjustment value (specified value) in the middle
speed mode and press [OK] key.
Enter the adjustment value of each mode which is specified on
the label attached on the high voltage power PWB.
GBK: XXX
The default value s specified for each model must be changed
as follows. 46cpm/56cpm machine: +5
Note that the adjustment value may differ depending on the high
voltage power PWB. Since the adjustment value label is attached
on the high voltage PWB, the PWB must be removed in order to
check the adjustment value. This is a troublesome procedure.
Therefore, it is advisable to put down the adjustment value in
advance.
Since the high voltage output cannot be checked with a digital multi
meter in this model, a judgment of the output must be made by
checking the print image quality.
 
2-C
Transfer current and voltage adjustment
This adjustment is needed in the following situations:
* When the high voltage PWB is replaced.
* U2 trouble has occurred.
* The PCU PWB has been replaced.
* The EEPROM of the PCU PWB has been replaced.
1)
Enter the SIM 8-6 mode.
2)
Select a mode to be adjusted with scroll key.
3)
Enter the adjustment value (specified value) and press [OK]
key. By setting the default value the specified voltage is out-
putted.
Item/Display
Content
Setting 
range
Default value
36
46
56
MID
DLE
A
MIDDLE 
SPEED 
DVB_K
Developing 
bias set value
0 - 700
-475V±5V
LO
W
A
LOW 
SPEED 
DVB_K
Developing 
bias set value
0 - 700
-475V±5V
 
EXECUTE 
EXECUTE 
or  after 30 sec 
10 key 
   S I MU L A TI O N   NO . 08 - 0 1
   
 0
T E S T
C L OS E
:  M ID D LE   S PE E D  D V B_ K
D V  S E TT I NG   A ND   OU T PU T
60 0
A
[  0  ~  7 0 0  ]
A:  6 0 0
O K
E X EC U TE
M I DD L E
LO W
10 K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
10 K E Y
1 0 KE Y
4
5
6
1
2
3
7
8
9
*
0
#
BA C K
S T AR T
E XI T
C LE A R
   S I MU L AT I O N   NO . 08 - 01
   
 0
T E ST
C L OS E
:  M ID D LE   SP E E D  D VB _ K
D V  S ET T I NG   AN D   OU T PU T
475
A
[  0  ~  7 0 0  ]
A :  4 75
O K
E X EC U TE
M ID D L E
LO W
10 K E Y
1 0K E Y
1 0K E Y
10 K E Y
1 0K E Y
1 0K E Y
10 K E Y
1 0K E Y
1 0K E Y
10 K E Y
1 0K E Y
1 0K E Y
10 K E Y
10 K E Y
1 0 KE Y
4
5
6
1
2
3
7
8
9
*
0
#
BA C K
S T AR T
EX I T
C LE A R
Item/Display
Content
Setting 
range
Default value
36 
cpm
46 
cpm
56 
cpm
A
TC PLAIN BW 
SPX
Transfer current 
standard paper 
front surface
0 - 255
90
107
111
B
TC PLAIN 
BW DPX
Transfer current 
standard paper 
back surface
0 - 255
82
94
99
C
TC HEAVY1 
BW SPX
Transfer current 
heavy paper front 
surface
0 - 255
82
82
82
D
TC HEAVY1 
BW DPX
Transfer current 
heavy paper  back 
surface
0 - 255
82
82
82
E
TC HEAVY2 
BW SPX
Transfer current 
heavy paper2
0 - 255
82
82
82
 
EXECUTE 
10 key 
or  after 30 sec 
EXECUTE 
   S IM U L AT I ON   N O .0 8 - 06
   
  0
T ES T
C LO S E
:  TC   PL A I N  B W  S P X
:  T C  P LA I N  B W  D P X
:  T C  H EA V Y 1  B W  S PX
:  T C  H EA V Y 1  B W  D PX
:  T C  H EA V Y 2  B W  S PX
:  T C  H EA V Y 3  B W  S PX
:  T C  O HP   B W
:  T C  E NV E L OP E  B W
:  TC   TH I N  B W
:  T C  A DS O R PT I ON
:  T C  G LO S S Y  B W
TH V   SE T TI N G  A N D  O UT P U T
90
A
[  0  ~  2 55   ]
A :    90
:  T C  I NT E R VA L  B I AS  M I D
B :    82
C :    82
D :    82
E :    82
F :    82
G :    82
H :    82
I :    82
J :    82
K :    82
L :    55
O K
E XE C UT E
1 0 K EY
10 K EY
10 K E Y
1 0 K EY
10 K EY
10 K E Y
1 0 K EY
10 K EY
10 K E Y
1 0 K EY
10 K EY
10 K E Y
1 0 K EY
1 0 K EY
1 0K E Y
4
5
6
1
2
3
7
8
9
*
0
#
B A CK
S TA R T
E X I T
CL E A R
   S I MU L A TI O N   NO . 08 - 0 6
   
 0
T E S T
C L OS E
:  T C  P LA I N  B W  S P X
:  T C  P L AI N   BW   DP X
:  T C  H E AV Y 1  B W  S P X
:  T C  H E AV Y 1  B W  D P X
:  T C  H E AV Y 2  B W  S P X
:  T C  H E AV Y 3  B W  S P X
:  T C  O H P  B W
:  T C  E N VE L O PE   BW
:  T C  T HI N   BW
:  T C  A D SO R P TI O N
:  T C  G L OS S Y  B W
T H V  S ET T IN G   AN D  O U TP U T
20 0
A
[  0  ~  2 5 5  ]
A:  2 0 0
:  T C  I N TE R V AL   BI A S  MI D
B:    8 2
C:    8 2
D:    8 2
E:    8 2
F:    8 2
G:    8 2
H:    8 2
I:    8 2
J:    8 2
K:    8 2
L:    5 5
O K
E X EC U TE
10 K EY
1 0K E Y
1 0K E Y
10 K EY
1 0K E Y
1 0K E Y
10 K EY
1 0K E Y
1 0K E Y
10 K EY
1 0K E Y
1 0K E Y
10 K EY
10 K EY
1 0 KE Y
4
5
6
1
2
3
7
8
9
*
0
#
B A C K
S T AR T
EX I T
C LE A R
Page of 127
Display

Click on the first or last page to see other MX-M364N / MX-565N (serv.man4) service manuals if exist.