Sharp MX-M266N / MX-M316N / MX-M356N (serv.man6) Service Manual ▷ View online
MX-M316N SIMULATION 6 – 42
* WARMUP END TIME LL: 1 count = 1s change
Other correction values: 1 count = 1 degree C change
* Items C/D: Correction of "-5" is made for item C and Item D in the case of B5 size
Code descriptions
* Correction value: (-49 - +49), Input value: Actual input value (1 - 99)
43-22
Purpose
Function (Purpose)
Used to perform the low-temperature, low-
humidity (L/L) environment correction for
the fusing temperature setting of each
paper (SIM43-04).
humidity (L/L) environment correction for
the fusing temperature setting of each
paper (SIM43-04).
Section
Operation/Procedure
1)
Select an item to be set with the scroll key.
2)
Enter the set value with 10-key.
3)
Press [OK] key. (The set value is saved.)
* PLAIN BW DUP APP CNT LL: 1 count = 1s change
Other correction values: 1 count = 1 degree C change
Code descriptions
* Setting value: Target value (-49 - +49), Input value: (Actual input value) 1 - 99
TH_UM
Fusing thermistor main (Front surface of paper)
HL_UM
Heater lamp main (Heat roller for front surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
Correction value
-49
-25
-5
0
+5
+25
+49
Input value
1
25
45
50
55
75
99
Item
Display
Content
Setting
range
Default
value
A
HL_UM PLAIN BW DUP LL
Correction value for the upper TH_UM black and white plain paper duplex under the LL
environment
environment
1 - 99
55
B
HL_US PLAIN BW DUP LL
Correction value for the upper TH_US black and white plain paper duplex under the LL
environment
environment
1 - 99
55
C
PLAIN BW DUP APP CNT LL
Correction value for applying number of sheets in black and white plain paper duplex under LL
environment
environment
1 - 99
50
D
HL_UM HEAVY BW DUP LL
Correction value for the upper TH_UM set value of black and white heavy paper duplex under the
LL environment
LL environment
1 - 99
55
E
HL_US HEAVY BW DUP LL
Correction value for the upper TH_US set value of black and white heavy paper duplex under the
LL environment
LL environment
1 - 99
55
F
HEAVY BW DUP APP CNT LL
Correction value for applying number of sheets in black and white heavy paper duplex under LL
environment
environment
1 - 99
50
TH_UM
Fusing thermistor main (Front surface of paper)
HL_UM
Heater lamp main (Heat roller for front surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
Setting value
-49
-25
-5
0
+5
+25
+49
Input value
1
25
45
50
55
75
99
MX-M316N SIMULATION 6 – 43
44
44-1
Purpose
Setting
Function (Purpose)
Used to set each correction operation func-
tion in the image forming (process) section.
tion in the image forming (process) section.
Section
Image process (Photoconductor/Develop-
ing/Transfer/Cleaning)
ing/Transfer/Cleaning)
Operation/Procedure
1)
Select an item to be set with the touch panel.
(The selected item is highlighted.)
(The selected item is highlighted.)
2)
Press [EXECUTE] key. (The set value is saved.)
CAUTION: Set the items to the default values unless a change is
specially required.
44-9
Purpose
Operation data display
Function (Purpose)
Used to display the result data of the high
density process control operation.
density process control operation.
Section
Image process (Photoconductor/Develop-
ing/Transfer/Cleaning)
ing/Transfer/Cleaning)
Operation/Procedure
Select a target display mode with [CPY/PRN], [OTHER] keys.
Item/Display
Content
Setting range
Default value
NOTE
MD_VG
Membrane decrease (GB) Enable/Disable setting
Black text on
white
background
(Inhibit: 0=NO)
White text on
black
background
(Allow: 1=YES)
white
background
(Inhibit: 0=NO)
White text on
black
background
(Allow: 1=YES)
Enable
MD_DV_LIFE
DV life correction (GB, DVB) Enable/Disable setting
Enable
MD_ENV
Environment correction (GB, DVB) Enable/Disable setting
Enable
MD_DUPLEX
Duplex print correction (GB, DVB) Enable/Disable setting
Enable
MD_LD
Membrane decrease life correction (laser power) Enable/Disable setting
Enable
MD_LD_ENV
Environment correction (laser power) Enable/Disable setting
Enable
TN_LIFE
Enable/Disable setting of the toner density life correction
Enable
TN_ENV
Enable/Disable setting of the toner density environment correction
Enable
TN_DUPLEX
Toner density duplex print correction Enable/Disable setting
disable
TN_COV
Enable/Disable setting of the toner density print ratio correction
Enable
TN_AREA
Enable/Disable setting of the toner density area correction
Enable
TN_DRIP
Enable/Disable setting of the toner density correction unconditional supply
Enable
TC
Enable/Disable setting of the transfer output correction
Enable
MX-M316N SIMULATION 6 – 44
*1: The left of the correction amount indicates the execution result, and the right indicates the reference value.
Mode
Page number
Item/Display
(*: Correction
value)
Content
Display
range
Default value
26/31cpm
35cpm
CPY/
PRN*
PRN*
1
1/2
(PROCESS)
(PROCESS)
REF (TS_OFF)
Left
GB ***
GB/DVB default value when TS is OFF
0 - 750
575
605
Right
DVB ***
0 - 650
400
430
ALL (TS_OFF)
Left
GB ***
GB/DVB value after addition or
subtraction of the correction amount
when TS is OFF
subtraction of the correction amount
when TS is OFF
0 - 750
575
605
Right
DVB ***
0 - 650
400
430
REF (TS_ON_C)
Left
GB ***
Copy GB/DVB default value when TS is
ON
ON
0 - 750
460
460
Right
DVB ***
0 - 650
320
320
ALL(TS_ON_C)
Left
GB ***
GB/DVB value after addition or
subtraction of the correction amount
when Copy TS is ON.
subtraction of the correction amount
when Copy TS is ON.
0 - 750
540
540
Right
DVB ***
0 - 650
400
400
REF (TS_ON_P)
Left
GB ***
Printer GB/DVB default value when TS is
ON
ON
0 - 750
390
390
Right
DVB ***
0 - 650
250
250
ALL (TS_ON_P)
Left
GB ***
GB/DVB value after addition or
subtraction of the correction amount
when Printer TS is ON
subtraction of the correction amount
when Printer TS is ON
0 - 750
390
390
Right
DVB ***
0 - 650
250
250
MD_VG
Left
GB ***
Drum membrane decrease correction
amount GB value
amount GB value
0 - 255
0
0
MD_DV_LIFE
Left
GB ***
Process developer life correction amount
GB/DVB value
GB/DVB value
-127 - +127
0
0
Right
DVB ***
-127 - +127
0
0
MD_ENV
Left
GB ***
Environment correction amount GB/DVB
value
value
-127 - +127
0
0
Right
DVB ***
-127 - +127
0
0
MD_DUPLEX
Left
GB ***
Duplex print correction amount GB/DVB
value
value
0 - 255
0
0
Right
DVB ***
0 - 255
0
0
CPY/
PRN*
PRN*
1
2/2 (LD)
REF (TS_OFF)
Left
LD (CP)
Laser power default value when TS is
OFF (CP/PRT)
OFF (CP/PRT)
0 - 255
For default values refer
to "Default values for
each item".
to "Default values for
each item".
Right
LD (PRT)
0 - 255
ALL (TS_OFF)
Left
LD (CP)
Laser power value after addition or
subtraction of the correction amount
when TS is OFF (CP/PRT)
subtraction of the correction amount
when TS is OFF (CP/PRT)
0 - 255
Right
LD (PRT)
0 - 255
REF (TS_ON_C)
Left
LD (CP)
Laser power default value when TS is ON
(CP/PRT)
(CP/PRT)
0 - 255
Right
LD (PRT)
0 - 255
ALL (TS_ON_C)
Left
LD (CP)
Laser power value after addition or
subtraction of the correction amount
when Copy TS is ON (CP/PRT)
subtraction of the correction amount
when Copy TS is ON (CP/PRT)
0 - 255
Right
LD (PRT)
0 - 255
MD_LD
Left
LD (CP)
Drum membrane decrease laser power
correction amount (CP/PRT)
correction amount (CP/PRT)
-127 - +127
0
0
Right
LD (PRT)
-127 - +127
0
0
MD_LD_ENV
Left
LD (CP)
Environment laser power correction
amount (CP/PRT)
amount (CP/PRT)
-127 - +127
0
0
Right
LD (PRT)
-127 - +127
0
0
OTHER
1/2
(TN/TC/MD)
(TN/TC/MD)
TN_TMP_AREA
***
Toner control display temperature/
humidity area
humidity area
1 - 8
4
4
TN_TMP_DATA
***
Toner control display temperature AD
value
value
0 - 1023
0
0
TN_HUD_DATA
***
Toner control display humidity AD value
0 - 1023
0
0
TC_TMP_AREA
***
Transfer display temperature/humidity
area
area
1 - 8
4
4
TC_TMP_DATA
***
Transfer display temperature AD value
0 - 1023
0
0
TC_HUD_DATA
***
Transfer display humidity AD value
0 - 1023
0
0
MD_VG_AREA
***
Membrane decrease drum traveling
distance area
distance area
1 - 15
1
1
MD_DV_LIFE_AREA
***
Developer life area for process
0 - 15
1
1
MD_ENV_AREA
***
Environment correction area
1 - 8
1
1
MD_DUPLEX_COUNTER
***
Duplex counter
0 - 300
0
0
MD_LD_AREA
***
Laser power area
0 - 15
1
1
MD_LD_ENV_AREA
***
Laser power environment area
0 - 8
4
4
2/2
(CRUM/CNT)
(CRUM/CNT)
DESTINATION
Left
xx
Machine side management CRUM
destination
destination
-
-
-
MODEL TYPE
xx
Model type of the machine
0 - 1
0
0
CRUM DEST_K
Right
xx
Crum destination
-
-
-
1
: ‘15/Aug.
1
MX-M316N SIMULATION 6 – 45
Default values for each item
Mode
Item/Display
Default value
35cpm machine
31cpm machine
26cpm machine
CPY/
PRN
PRN
REF (TS_OFF)
LD (CP)
170
160
160
LD (PRT)
170
160
160
ALL (TS_OFF)
LD (CP)
170
160
160
LD (PRT)
170
160
160
REF (TS_ON_C)
LD (CP)
170
160
160
LD (PRT)
170
160
160
ALL (TS_ON_C)
LD (CP)
170
160
160
LD (PRT)
170
160
160
Click on the first or last page to see other MX-M266N / MX-M316N / MX-M356N (serv.man6) service manuals if exist.