Sharp MX-M266N / MX-M316N / MX-M356N (serv.man6) Service Manual ▷ View online

MX-M316N  SIMULATION  6 – 38
 
41-3
Purpose
Operation test/check
Function (Purpose)
Used to check the operations of the docu-
ment size sensor and the control circuit.
Section
Operation/Procedure
The detection output level (A/D value) of OCSW and the document
sensor (PD1 - PD7) is displayed in real time.
The light receiving range of PD1 - PD7 is 1 - 255. (Default: 128)
 
43
 
43-1
Purpose
Setting
Function (Purpose)
Used to set the fusing temperature in each
mode.
Section
Operation/Procedure
1)
Select an item to be set with scroll keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
Item/Display
Content
Detection level range
OCSW
Original cover SW
0-1 ("1" to Close)
PD1
Document detection 1
0 - 255 
PD2
Document detection 2
0 - 255 
PD3
Document detection 3
0 - 255 
PD4
Document detection 4
0 - 255 
PD5
Document detection 5
0 - 255 
PD6
Document detection 6
0 - 255 
PD7
Document detection 7
0 - 255 
Item/Display
Content
Setting 
range
Default value
26cpm
31cpm
35cpm
Group A
Group B
Group A
Group B
Group A
Group B
SW-
A
SW-
B
SW-
A
SW-
B
SW-
A
SW-
B
SW-
A
SW-
B
SW-
A
SW-
B
SW-
A
SW-
B
A
HL_UM READY
Ready standby TH_UM set 
value
70 - 220
185
185
190
190
185
185
190
190
195
195
195
195
B
HL_US READY
Ready standby TH_US set 
value
70 - 220
180
180
200
200
180
180
200
200
195
195
195
195
C
HL_UM PLAIN 
PAPER BW
Black-White plain paper 
TH_UM set value
70 - 220
190
195
195
200
190
195
195
200
195
200
195
200
D
HL_US  PLAIN 
PAPER BW
Black-White plain paper 
TH_US set value
70 - 220
190
195
195
200
190
195
195
200
195
200
195
200
E
WARMUP FUMON 
HL_UM T
Fusing motor pre-rotation start 
TH_US set value
0 - 200
150
150
150
150
150
150
150
150
150
150
150
150
F
WARMUP FUMOFF 
HL_UM T
Fusing motor previous rotation 
complete time
0 - 60
0
0
0
0
0
0
0
0
0
0
0
0
G
WARMUP END 
TIME
Warm-up complete time
0 - 20
18
18
18
18
18
18
18
18
18
18
18
18
H
HL_UM  THIN 
PAPER
Thin paper TH_UM set value
70 - 220
190
195
190
195
185
185
I
HL_US  THIN 
PAPER
Thin paper TH_US set value
70 - 220
190
195
190
195
185
185
J
HL_UM  HEAVY 
PAPER
Heavy paper TH_UM set value
70 - 220
200
200
200
200
200
200
200
200
200
200
200
200
K
HL_US HEAVY 
PAPER
Heavy paper TH_US set value
70 - 220
200
200
200
200
200
200
200
200
200
200
200
200
L
HL_UM LABEL 
PAPER
Label paper TH_UM set value
70 - 220
200
200
200
200
200
200
M
HL_US LABEL 
PAPER
Label paper TH_US set value
70 - 220
200
200
200
200
200
200
N
HL_UM  OHP 
PAPER
OHP-TH_UM set value
70 - 220
190
195
190
195
195
195
1
: ‘15/Aug.
1
MX-M316N  SIMULATION  6 – 39
Code descriptions
List of destination groups
O
HL_US  OHP 
PAPER
OHP-TH_US set value
70 - 220
190
195
190
195
195
195
P
HL_UM  ENV 
PAPER
Envelope TH_UM set value
70 - 220
205
205
205
205
210
210
Q
HL_US  ENV 
PAPER
Envelope TH_US set value
70 - 220
205
205
205
205
210
210
R
HL_UM E-STAR
Preheating TH_UM set value
70 - 220
95
95
95
95
95
95
95
95
95
95
95
95
S
HL_US E-STAR
Preheating TH_US set value
70 - 220
95
95
95
95
95
95
95
95
95
95
95
95
T
HL_UM PRE-JOB
TH_UM set value when 
recovery from Warm-Up
70 - 220
180
180
190
190
180
180
190
190
180
180
190
190
U
HL_UM 
WARMUP_120L
TH_UM set value when Warm-
Up at 120 degree C or below
70 - 220
180
180
190
190
180
180
190
190
205
205
205
205
V
HL_US 
WARMUP_120L
TH_US set value when Warm-
Up at 120 degree C or below
70 - 220
180
180
190
190
180
180
190
190
205
205
205
205
W
LO_WARMUP_TIM
E
U, V applying time (Timer from 
completion of Ready)
0 - 255
0
0
0
0
0
0
0
0
0
0
0
0
X
HL_UM 
WARMUP_120H
TH_LM set value when Warm-
Up at 120 degree C or above
70 - 220
180
180
190
190
180
180
190
190
180
180
190
190
Y
HL_US 
WARMUP_120H
TH_US set value when Warm-
Up at 120 degree C or above
70 - 220
180
180
190
190
180
180
190
190
180
180
190
190
Z
HI_WARMUP_TIM
E
X, Y applying time (Timer from 
completion of Ready)
0 - 255
0
0
0
0
0
0
0
0
0
0
0
0
AA
HI_WU_FM_ON_T
MP
FM prior rotation start TH_US 
when Warm-Up at alpha 
degree C or above
0 - 220
0
0
0
0
0
0
0
0
0
0
0
0
AB
HI_WU_END_TIME
Warm-Up completion time 
when Warm-Up at alpha 
degree C or above
0 - 60
18
18
18
18
18
18
18
18
18
18
18
18
AC
HI_WU_JOB_SET_
TMP 1
Job enable TH_UM 
temperature 1 when Warm-Up 
at alpha degree C or above
30 - 220
180
180
190
190
180
180
190
190
205
205
205
205
AD
HI_WARMUP_BOR
DER
Threshold value alpha to which 
U - W is applied
1 - 119
60
60
60
60
60
60
60
60
60
60
60
60
AE
LO_WU_JOB_SET
_TMP 1
Job enable TH_UM 
temperature 1 when Warm-Up 
at alpha degree C or below
70 - 220
180
180
190
190
180
180
190
190
205
205
205
205
AF
JOBEND_FUMON_
TIME
After rotating time when a job is 
completed
0 - 60
0
0
0
0
0
0
0
0
0
0
0
0
AG
HI_WU_JOB_SET_
TMP 2
Job enable TH_UM 
temperature 2 when Warm-Up 
at alpha degree C or above
70 - 220
180
180
190
190
180
180
190
190
180
180
190
190
AH
LO_WU_JOB_SET
_TMP 2
Job enable TH_UM 
temperature 2 when Warm-Up 
at alpha degree C or below
70 - 220
180
180
190
190
180
180
190
190
180
180
190
190
Item/Display
Content
Setting 
range
Default value
26cpm
31cpm
35cpm
Group A
Group B
Group A
Group B
Group A
Group B
SW-
A
SW-
B
SW-
A
SW-
B
SW-
A
SW-
B
SW-
A
SW-
B
SW-
A
SW-
B
SW-
A
SW-
B
TH_UM
Fusing thermistor main (Front surface of paper)
HL_UM
Heater lamp main (Heat roller for front surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
Group
Destination
Group A
U. S. A
CANADA
INCH
-
-
Group B
EUROPE
U. K
AUS.
AB_A
AB_B
1
: ‘15/Aug.
1
1
MX-M316N  SIMULATION  6 – 40
 
43-4
Purpose
Setting
Function (Purpose)
Used to set the fusing temperature 2 in
each mode.
Section
Operation/Procedure
1)
Select an item to be set with the scroll key.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
Code descriptions
List of destination groups
Ite
m
Display
Content
Setting 
range
Default value
26cpm
31cpm
35cpm
Group A
Group B
Group A
Group B
Group A
Group B
SW-
A
SW-
B
SW-
A
SW-
B
SW-
A
SW-
B
SW-
A
SW-
B
SW-
A
SW-
B
SW-
A
SW-
B
A
HL_UM PLAIN 
PAPER BW DUP
Black and white plain paper 
duplex TH_UM set value
70 - 220
190
195
190
195
195
195
B
HL_US  PLAIN 
PAPER BW DUP
Black and white plain paper 
duplex TH_US set value
70 - 220
190
195
190
195
195
195
C
PLAIN  PAPER  BW 
DUP APP CNT
Black and white plain paper 
duplex applying number of 
sheets
0 - 255
0
0
0
0
0
0
D
HL_UM  HEAVY 
PAPER BW DUP
Black and white heavy paper 
duplex TH_UM set value
70 - 220
190
195
190
195
195
195
E
HL_US HEAVY 
PAPER BW DUP
Black and white heavy paper 
duplex TH_US set value
70 - 220
190
195
190
195
195
195
F
HEAVY PAPER BW 
DUP APP CNT
Black and white heavy paper 
duplex applying number of 
sheets
0 - 255
0
0
0
0
0
0
TH_UM
Fusing thermistor main (Front surface of paper)
HL_UM
Heater lamp main (Heat roller for front surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
Group
Destination
Group A
U. S. A
CANADA
INCH
-
-
Group B
EUROPE
U. K
AUS.
AB_A
AB_B
1
: ‘15/Aug.
1
1
MX-M316N  SIMULATION  6 – 41
 
43-10
Purpose
Setting
Function (Purpose)
Used to set the postcard feed cycle
Section
Operation/Procedure
1)
Enter the set value with 10-key.
2)
Press [OK] key. (The set value is saved.)
 
43-20
Purpose
Function (Purpose)
Used to perform the low-temperature, low-
humidity (L/L) environment correction for
the fusing temperature setting of each
paper (SIM43-01).
Section
Operation/Procedure
1)
Select an item to be set with the scroll key.
2)
Enter the set value with 10-key.
3)
Press [OK] key. (The set value is saved.)
Item
Display
Content
Setting 
range
Default 
value
A
POSTCARD CYCLE
Postcard feed cycle
1 - 99
50
Item
Display
Content
Setting 
range
Default 
value
A
HL_UM READY LL
Correction value for TH_UM set value in ready standby under LL environment
1 - 99
55
B
HL_US READY LL
Correction value for TH_US set value in ready standby under LL environment
1 - 99
55
C
HL_UM PLAIN BW LL
Correction value for black and white plain paper TH_UM set value under LL environment
1 - 99
55
D
HL_US PLAIN BW LL
Correction value for black and white plain paper TH_US set value under LL environment
1 - 99
55
E
WARMUP FUMON HL_US T 
LL
Correction value for fusing motor previous rotation start TH_UM set value under LL environment
1 - 99
50
F
WARMUP FUMOFF LL
Fusing motor prior rotation completion time under LL environment
1 - 99
50
G
WARMUP END TIME LL
Correction value for warm-up complete time under LL environment
1 - 99
50
H
HL_UM THIN LL
Correction value for thin paper TH_UM set value under LL environment
1 - 99
55
I
HL_US THIN LL
Correction value for thin paper TH_US set value under LL environment
1 - 99
55
J
HL_UM HEAVY LL
Correction value for heavy paper TH_UM set value under LL environment
1 - 99
55
K
HL_US HEAVY LL
Correction value for heavy paper TH_US set value under LL environment
1 - 99
55
L
HL_UM LABEL LL
Correction value for label paper TH_UM set value under LL environment
1 - 99
55
M
HL_US LABEL LL
Correction value for label paper TH_US set value under LL environment
1 - 99
55
N
HL_UM OHP LL
Correction value for OHP-TH_UM set value under LL environment
1 - 99
55
O
HL_US OHP LL
Correction value for OHP-TH_US set value under LL environment
1 - 99
55
P
HL_UM ENV LL
Correction value for envelope TH_UM set value under LL environment
1 - 99
55
Q
HL_US ENV LL
Correction value for envelope TH_US set value under LL environment
1 - 99
55
R
HL_UM E-STAR LL
Correction value for preheating TH_UM set value under LL environment
1 - 99
55
S
HL_US E-STAR LL
Correction value for preheating TH_US set value under LL environment
1 - 99
55
T
HL_UM PRE-JOB LL
Correction value for the set value of TH_UM when restoring from preheating under LL environment
1 - 99
50
U
HL_UM WARMUP_120L LL
Correction value for TH_UM set value in Warm-Up at 120 degree Cor below under LL environment
1 - 99
55
V
HL_US WARMUP_120L LL
Correction value for TH_US set value in Warm-Up at 120 degree C or below under LL environment
1 - 99
55
W
LO_WARMUP_TIME_LL
Correction value for O, P applying time (timer from Ready complete) under LL environment
1 - 99
50
X
HL_UM WARMUP_120H LL
Correction value for TH_UM set value in Warm-Up at 120 degree C or above under LL environment
1 - 99
55
Y
HL_US WARMUP_120H LL
Correction value for TH_US set value in Warm-Up at 120 degree C or above under LL environment
1 - 99
55
Z
HI_WU_TIME_LL
Correction value for R, S applying time (timer from Ready complete) under LL environment
1 - 99
50
AA
HI_WU_FM_ON_TMP_LL
Correction value for FM prior rotation start TH_UM in Warm-Up at alpha degree C or above under LL 
environment
1 - 99
50
AB
HI_WU_END_TIME_LL
Correction value for Warm-Up completion time in Warm-Up at alpha degree C or above under LL 
environment
1 - 99
50
AC
HI_WU_JOB_SET_TMP_LL
Correction value for Job enable TH_UM temperature (1) when Warm-Up at alpha degree C or above 
under LL environment
1 - 99
50
AD
HI_WARMUP_BORDER_LL
Correction value for the threshold value alpha applying SIM43-1-U - W under LL environment
1 - 99
50
AE
LO_WU_JOB_SET_TMP_LL
Correction value for Job enable TH_UM temperature (1) when Warm-Up at alpha degree C or below 
under LL environment
1 - 99
50
AF
JOBEND_FUMON_TIME LL 
Correction value for the after rotation time when completing a job under LL environment
1 - 99
50
AG
HI_WU_JOB_SET_TMP 2 
LL
Correction value for Job enable TH_UM temperature (2) when Warm-Up at alpha degree C or above 
under LL environment
1 - 99
50
AH
LO_WU_JOB_SET_TMP 2 
LL
Correction value for Job enable TH_UM temperature (2) when Warm-Up at alpha degree C or below 
under LL environment
1 - 99
50
Page of 127