DOWNLOAD Sharp MX-M232D (serv.man3) Service Manual ↓ Size: 9.62 MB | Pages: 127 in PDF or view online for FREE

Model
MX-M232D (serv.man3)
Pages
127
Size
9.62 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual December 2011.
File
mx-m232d-sm3.pdf
Date

Sharp MX-M232D (serv.man3) Service Manual ▷ View online

MX-M182 SIMULATIONS 7-5
02
08
SPF/RSPF paper feed solenoid operation check
Used to drive the SPF/RSPF paper feed solenoid (PSOL) 20 times in the cycle of 500msec of "ON" and 
500msec of "OFF." After completion of the process, the machine returns to the sub code input window.
When [INTERRUPT] key is pressed, the machine returns to the sub code input window.
When [CA] key is pressed, the machine exits the simulation mode. 
(Only when the 
SPF/RSPF is 
installed.}
09
RSPF reverse solenoid operation check
Used to drive the RSPF reverse solenoid (RSOL) 20 times in the cycle of 500msec of "ON" and 500msec of 
"OFF." After completion of the process, the machine returns to the sub code input window.
When [INTERRUPT] key is pressed, the machine returns to the sub code input window.
When [CA] key is pressed, the machine exits the simulation mode.
(Only when the 
RSPF is installed.)
11
SPF/RSPF PS release solenoid operation check
Used to drive the SPF/RSPF PS release solenoid (CLH) 20 times in the cycle of 500msec of "ON" and 
500msec of "OFF." After completion of the process, the machine returns to the sub code input window.
When [INTERRUPT] key is pressed, the machine returns to the sub code input window.
When [CA] key is pressed, the machine exits the simulation mode.
(Only when the 
SPF/RSPF is 
installed.)
03
02
Shifter/job separator sensor status display
Used to monitor the sensors related to the shifter and the job separator and display the sensor status on the 
LCD. An active sensor is highlighted.
*
Displayed only when the job separator is installed except for SFTH.
(Sensor of shifter is 
Japan only)
(Only when the job 
separator is 
installed.)
Main 
code
Sub 
code
Contents
Remark
Sim2-8  SPUS CHECK
PRESS OK KEY EXEC
Sim2-8  SPUS CHECK
EXEC
[OK] key or [START] Key
(Initial window)
(Execution window)
Sim2-9  SPFS CHECK
PRESS OK KEY EXEC
Sim2-9  SPFS CHECK
EXEC
[OK] key or [START] Key
(Initial window)
(Execution window)
Sim2-11  CLH CHECK
PRESS OK KEY EXEC
Sim2-11  CLH CHECK
EXEC
[OK] key or [START] Key
(Initial window)
(Execution window)
Sim3-2 SENSOR
SFTHP
TRYF
JSUP
TRYD
JSDL
Displayed name  :Sensor name
SFTHP 
:Shifter home position sensor
JSUP 
:Job separator upper limit sensor
JSDL 
:Job separator lower limit sensor
TRYF 
:Tray full sensor
TRYD 
: Paper exit sensor
MX-M182 SIMULATIONS 7-6
03
03
Shifter operation check
Used to reciprocate the shifter 4 times.
During execution, the status of the shifter HP sensor is displayed on the right upper section of the screen. 
(When the sensor is detected, the display is highlighted.)
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window.
*
When the above [CA] key or [INTERRUPT] key is pressed during operation of the shifter, the shifter is 
returned to the home position before terminating the operations.
Japan only
04
Job separator operation check
Used to operate the job separator up and down for 30sec.
During operation, the status of the upper limit sensor and the lower limit sensor is displayed on the right 
upper section of the display.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window.
When the operation is interrupted, the job separator is shifted to the home position before terminating the 
simulation similarly to the shifter.
(Only when the job 
separator is 
installed.)
11
Shifter home position check
Used to check the operations of the shifter HP sensor and the shifter. When this simulation is executed, the 
initial menu is displayed. By the following key operations, the left operation and the right operation of the 
home position sensor and the shifter can be executed separately.
[ ] key: Shifts to R side by the specified steps.
[ ] key: Shifts to F side by the specified steps.
[ ] key: Shift to the home position.
[SFTHP] is highlighted when the HP sensor is detected.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window. 
Japan only
Main 
code
Sub 
code
Contents
Remark
Sim3-3  SHIFTER CHK
PRESS OK KEY EXEC
Sim3-3  SHIFTER CHK
EXEC
SFTHP
[OK] key or [START] Key
(Initial window)
(Execution window)
Sim3-4  JOBSEPA CHK
PRESS OK KEY EXEC
Sim3-4  JOBSEPA CHK
EXEC
JSDL
JSUP
[OK] key or [START] Key
(Initial window)
(Execution window)
Display
name
JSUP
Job separator 
upper limit sensor
JSDL
Job separator 
lower limit sensor
Sensor
name
Sim3-11 SHIFTER CHK
SFTHP
(Initial window)
[    ]:R [    ]:HP [    ]:F
MX-M182 SIMULATIONS 7-7
05
01
Operation panel display check
<LED/LCD check mode>
Used to check the operations (ON, display) of the LED and the LCD on the operation panel.
When this simulation is executed, all LED's on the operation panel (including 7SEG) are lighted and 
checking LCD is started.
For the operation check of LCD, the area is divided into two sections; upper section and lower section, and 
the display cycle of Normal 
 Dark 
 Light 
 Off is repeated in each section. Each display period is 
2sec.
When [INTERRUPT] key is pressed in the LED check mode, the machine returns to the sub code input 
window.
When [CA] key is pressed, the machine exits the simulation mode.
When [START] key is pressed during LCD display, the machine goes to the key input check mode.
<Key input check mode>
Used to check that the keys on the operation panel are properly detected.
When the machine enters the key input check mode, the initial menu is displayed.
When any key is pressed, the value on the right lower side is counted up.
If a key is pressed once, it is not counted again.
When [CA] key is pressed for the first time, it is counted. When it is pressed for the second time, the 
simulation mode is terminated.
When [INTERRUPT] key is pressed for the first time, it is counted. When it is pressed for the second time, 
the window returns to the sub code input standby window.
*
Note for the key input check mode
[START] key must be pressed at the end. If it is pressed midway, the simulation judges that the last key 
is pressed and terminates the check mode. Multi input of tow or more keys is ignored. 
Main 
code
Sub 
code
Contents
Remark
Sim5-1 LCD/LED CHK.
Normal
Sim5-1 LCD/LED CHK.
Dark
Sim5-1 LCD/LED CHK.
Light
Sim5-1 LCD/LED CHK.
Normal
Dark
Sim5-1 LCD/LED CHK.
Light
Sim5-1 LCD/LED CHK.
Sim5-1 LCD/LED CHK.
Off
Sub code input standby window
Sim5-1 LCD/LED CHK.
0
(Initial window)
MX-M182 SIMULATIONS 7-8
05
02
Fusing lamp and cooling fan operation check
Used to check the operations of the heater lamp and the cooling fan and the peripheral circuits.
When this simulation is executed, the following initial menu is displayed.
When this simulation is executed, the fusing lamp repeats ON/OFF 5 times in the cycle of 500ms.
The cooling fan motor is rotated during that period. (The cooling fan, however, is rotated for about 8sec.) 
After completion of the operation, the machine returns to the sub code input window. 
03
Copy lamp lighting check
Used to check the operations of the copy lamp and its peripheral circuit.
When this simulation is executed, the following initial menu is displayed.
When [OK] key or [START] key is pressed, the copy lamp is lighted for about 5sec.
After passing for 5sec, the machine returns to the sub code input window. 
06
01
Paper feed/transport solenoid operation check
When this simulation is executed, the names of the solenoids which can be operated are displayed. Select a 
load to be operated with the numeric keys.
02
Resist roller solenoid (RRS) operation check
When this simulation is executed, the machine goes to the execution start window. When [OK] key or 
[START] key is pressed, the resist roller solenoid (RRS) repeats ON of 500ms and OFF of 500ms 20 times. 
When the operation is completed, the machine returns to the sub code input window. 
When [INTERRUPT] key is pressed, the machine returns to the sub code input window. When [CA] key is 
pressed, the machine exits the simulation mode. 
Main 
code
Sub 
code
Contents
Remark
Sim5-2        HT LAMP
PRESS OK KEY EXEC
Sim5-2        HT LAMP
EXEC
[OK] key or [START] Key
(Initial window)
(Execution window)
Sim5-3  COPY LAMP
PRESS OK KEY EXEC
Sim5-3  COPY LAMP
EXEC
[OK] key or [START] Key
(Initial window)
(Execution window)
Sim6-1 OUTPUT CHECK
Sim6-1 OUTPUT CHECK
Sim6-1 OUTPUT CHECK
1:CPSOL
2:PSOL1
3:PSOL2
4:PSOL3
5:HPSOL
6:FSOL2
EXEC
1/2
1
(Load selection window)
1:CPSOL
2:PSOL1
3:PSOL2
4:PSOL3
5:HPSOL
6:FSOL2
EXEC
1/2
2
1:CPSOL
2:
PSOL1
3:PSOL2
4:PSOL3
5:HPSOL
6:FSOL2
EXEC
1/2
2
(Load selection window)
Numeric keys
After completion
of execution
[OK] key or [START] Key
1: CPSOL 
:Cassette 1 paper feed solenoid
2: PSOL1 
:Cassette 2 paper feed solenoid (*)
3: PSOL2 
:Cassette 2 paper feed solenoid (*)
4: PSOL3 
:Cassette 3 paper feed solenoid (*)
5: HPSOL 
:Manual feed tray paper feed solenoid 
6: FSOL2 
:Cassette 2 transport solenoid (*)
7: FSOL3 
:Cassette 3 transport solenoid (*)
(*) Supported only for the model with the option installed.
     Skipped for the other models without installation.
During execution, the selected solenoid repeats
ON/OFF 20 times for every 500ms.
(Execution window)
Sim6-2  RRS CHECK
PRESS OK KEY EXEC
Sim6-2  RRS CHECK
EXEC
[OK] key or [START] Key
(Execution start window)
(Execution window)
Page of 127
Display

Click on the first or last page to see other MX-M232D (serv.man3) service manuals if exist.