DOWNLOAD Sharp MX-M232D (serv.man3) Service Manual ↓ Size: 9.62 MB | Pages: 127 in PDF or view online for FREE

Model
MX-M232D (serv.man3)
Pages
127
Size
9.62 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual December 2011.
File
mx-m232d-sm3.pdf
Date

Sharp MX-M232D (serv.man3) Service Manual ▷ View online

MX-M182 SIMULATIONS 7-17
24
10
FAX-related counter clear
Used to clear the current FAX send/receive counter value (number of pages of send/receive), the 
accumulated time of send/receive, and the print counter to 0.
13
Scanner counter clear
Used to clear the scanner counter.
[OK] key or [START] key: Clears the scanner counter and shifts to the sub code input window. 
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window. 
14
SPF/RSPF jam total counter clear
Used to clear the SPF/RSPF jam total counter.
[OK] key or [START] key: Clears the SPF/RSPF jam total counter and shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
(Only when the 
SPF/RSPF is 
installed.)
15
Scanner mode counter clear
Used to clear the scanner mode counter.
[OK] key or [START] key: Clears the scanner mode counter and shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window. 
Main 
code
Sub 
code
Contents
Remark
SEND
PAGE: xx, xxx, xxx
TIME: hhhhhhhh:mm:ss
 EXEC
CLEAR FAX COUNTER
3:PRINT PAGE
  (1 - 3) 
X
Sim24-10 CLR COUN.
RECEIVE
PAGE: xx, xxx, xxx
TIME: hhhhhhhh:mm:ss
 EXEC
Sim24-10 CLR COUN.
CLEAR FAX COUNTER
1:SEND
2:RECEIVE
  (1 - 3) 
X
Sim24-10 CLR COUN.
PRINT PAGE
xxxxxxxx
 EXEC
[1] key
[2] key
[OK] key
[OK] key
[OK] key
[OK] key
[3] key
[OK] key
[OK] key
When the number of pages of send is cleared, the PC-FAX counter is also cleared.
Sim24-10 CLR COUN.
SEND COUN. CLEARED
Sim24-10 CLR COUN.
RCV COUN. CLEARED
Sim24-10 CLR COUN.
FAX COUN. CLEARED
Sim24-10 CLR COUN.
Sim24-10 CLR COUN.
Return
Return
Return
CA key 
:  Simulation cancel
Interrupt key :  Sub code input window
Sim24-13 COUNTER CLR
AER YOU SURE? EXEC
SCAN COUNTER 
CLEAR
Sim24-14 COUNTER CLR
AER YOU SURE? EXEC
SPF JAM COUNTER 
CLEAR
Sim24-15 COUNTER CLR
AER YOU SURE? EXEC
SCANNER MODE
COUNTER CLEAR
MX-M182 SIMULATIONS 7-18
25
01
Main motor operation check (Cooling fan motor rotation check)
When [OK] key or [START] key is pressed, the main motor (as well as the duplex motor in the case of the 
duplex model) is rotated for 30 sec.
If the developing unit is installed to save toner consumption at that time, the developing bias, the main 
charger, and the grid are also outputted.
In addition, since laser discharge is required when the motor is stopped, the polygon motor is also operated. 
Check if the developing unit is installed or not. If it is not installed, the previous high voltage is not outputted 
and only the motor is rotated.
After completion of 30sec operation, the machine shifts to the sub code input window.
*
This simulation must not be executed with the door open/close switch forcibly turned ON.
After completion of the process, the machine shifts to the sub code input window. 
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Interrupts the output operation, and shifts to the sub code input window. 
02
Auto developer adjustment (Initial setting of toner density when replacing developer)
To execute this simulation, perform the following procedures.
[Procedures]
1) Check to confirm that the machine power is turned OFF. Install the DV unit.
2) With the cover open, turn ON the machine power.
3) The machine goes to the SIM25-02 mode. ("Cover open MSG" is displayed. Start LED: OFF.)
4) Close the side cover. (Start LED:ON)
5) Press [OK] key or [START] key.
When [OK] key or [START] key is pressed, the main motor rotates for 3 minutes to determine the toner 
sensor reference value and clear the developer rotation time, in addition, the developer counter is cleared.
When the procedures are completed normally, the ATC sensor reference value is displayed on the value 
display section. In case of an error, the following screen is displayed.
Note:
When the machine is not in the simulation mode, if the front cover is closed and the machine power is turned 
ON, toner may be supplied from the toner cartridge to the developer cartridge. 
Under this state, the toner density reference control level adjustment cannot be performed properly. 
If, therefore, the front cover is closed and the machine power is turned ON when the machine is not in the 
simulation mode, dispose developer, supply new developer, and adjust the toner density reference level.
It takes about 3 minutes to complete the SIM25-02. Never open the front cover or turn OFF the machine 
power during execution of this simulation. 
Main 
code
Sub 
code
Contents
Remark
Sim25-1  MAIN MOTOR
PRESS OK KEY EXEC
Sim25-1  MAIN MOTOR
EXEC
[OK] key or [START] Key
(Execution start window)
(Execution window)
[OK] key or [START] Key
(Execution start)
(Normally completed)
(EL error)
(EU error)
(Executing)
Sim25-2 AutoDv ADJ.
 
DEVELOPER ADJUST
[nnn]
Sim25-2 AutoDv ADJ.
DEVELOPER ADJUST
PRESS OK KEY   EXEC
EXEC
Sim25-2 AutoDv ADJ.
DEVELOPER ADJUST
COMPLETE
[nnn]
Sim25-2 AutoDv ADJ.
DEVELOPER ADJUST
EU trouble
[nnn]
Sim25-2 AutoDv ADJ.
DEVELOPER ADJUST
EL trouble
[nnn]
MX-M182 SIMULATIONS 7-19
25
10
Polygon motor operation check
When [OK] key or [START] is pressed, the polygon motor is rotated for 30sec.
After completion of the process, the machine shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Interrupts the output operation, and shifts to the sub code input window. 
26
01
Job separator setting
Used to set YES/NO of installation of the hob separator.
After installation of the job separator, setting must be manually set to YES. 
[CA] key: Exits the simulation mode. (When setting is changed, the machine exits the simulation mode and 
performs the hard reset.)
[INTERRUPT] key: Shifts to the sub code input window. (When setting is changed, it is invalid.)
[START] key:  Setting contents are saved in the EEPROM and the machine shifts to the code input window.   
(When setting is changed, the machine does not shift to the code input window.)
02
Size setting
Used to set Enable/Disable of FC (8.5" x 13") size detection and mexican legal size detection.
Detection size when FC (8.5" x 13") size and mexican legal size document is used.
* For destinations other than the above, this setting is invalid.
Main 
code
Sub 
code
Contents
Remark
Sim25-10 LSU CHECK
PRESS OK KEY EXEC
Sim25-10 LSU CHECK
EXEC
[OK] key or [START] Key
(Execution start window)
(Execution window)
Sim26-1 JBS SET
1:JOB SEPARATOR
 0=NONE
 1=SEPARATOR
                 [   0-1]
0 : No job separator
1 : Job separator provided 
0
0
Window display
Code number
Setting
1: B4/LG, FC
0
FC detection disable (The set values to items marked with 
 are ignored.)
1
(Follows the setting of items below marked with  .)
2: Use Mex Legal
0
 Mexican legal detection disable (FC detection enable)
1
 Mexican legal detection enable (FC detection disable)
Unit to 
be used
Destination
Destination
Detection size
1: B4/LG, 
FC: 0
1: B4/LG, FC
2: Use Mex 
Legal: 0
2: Use Mex 
Legal: 1
Document SPF
EX Japan AB 
series (FC)
FC(8.5"x13")
B4
FC
(8.5"x13")
Mexican legal
(8.5"x13.4")
B4
Inch series 
(FC)
FC(8.5"x13")
LG
(8.5"x14")
LG(8.5"x14")
Sim26-2 SIZE SET
1:B4/LG,FC
2:Use Max Legal 
0
                 [   0-1]
0
0
Code: Setting
0 : Detection disabled
1 : FC detection enabled
MX-M182 SIMULATIONS 7-20
26
03
Auditor setting
Used to set the auditor.
*
When the coin vendor mode is selected:
1. Sort auto select is OFF.
2. For Japan, the duplex copy use inhibition setting is ON (inhibited).
3. When the auditor mode exclusive-setting is ON (manual paper feed inhibited) and the standard tray is set 
to the manual feed tray, the standard tray setting is set to the main tray. 
Default:
0
04
Copier duplex setting
Used to set YES/NO of duplex setting.
This must be set to ON when the duplex unit is installed. If this setting is set to OFF on the duplex machine, 
the duplex motor does not rotate and paper is not discharged normally, resulting in a paper jam.
Default:
0: MX-M182
1: MX-M182D
MX-M202D
MX-M232D
05
Count mode setting
Used to set the count-up number of the total counter, the developer counter, and the maintenance counter 
individually when a special paper (A3/WLT/8K) is passed.
When this simulation is executed, the current set value is displayed.
[1]-[3]:
Enter a value with numeric keys, and press [OK] key or [START] key to save the current adjustment value to 
the EEPROM. The machine returns to the sub code input window. 
Default:
0
Main 
code
Sub 
code
Contents
Remark
Sim26-3 AUDITOR SET
1:AUDITOR
 0=P10 
1=VENDOR
  
2=OTHER
                 [   0-2]
Code: Mode
0 : Built-in auditor mode
1 : Coin vendor
2 : Other
0
0
Sim26-4 DUPLEX SET
1:DUPLEX
 0=OFF 
1=ON 
                
                  [   0-1]
Code: Duplex setting
0 : OFF
1 : ON
0
0
Sim26-5 COUNT MODE
1:COUNT MODE
  
                
                  [   0-3]
1
1
Setting
Total/Developer
Maintenance
0
+2
+2
1
+1
+2
2
+2
+1
3
+1
+1
Page of 127
Display

Click on the first or last page to see other MX-M232D (serv.man3) service manuals if exist.