DOWNLOAD Sharp MX-M232D (serv.man3) Service Manual ↓ Size: 9.62 MB | Pages: 127 in PDF or view online for FREE

Model
MX-M232D (serv.man3)
Pages
127
Size
9.62 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual December 2011.
File
mx-m232d-sm3.pdf
Date

Sharp MX-M232D (serv.man3) Service Manual ▷ View online

MX-M182 ADJUSTMENT 6-6
(3) Main scanning direction (FR direction) distortion 
adjustment
This adjustment must be performed in the following cases:
• When the mirror base drive wire is replaced.
• When the lamp unit, or No. 2/3 mirror holder is replaced.
• When a copy as shown is made.
1) Set A3 (11" x 17") white paper on the original table as shown below.
2) Open the original cover and make a normal (100%) copy. 
3) Measure the width of the black background at the lead edge and at 
the rear edge.
If the width (La) of the black background at the lead edge is equal that 
(Lb) at the rear edge, there is no need to execute the following 
procedures of 4) - 7).
4) Loosen the mirror base drive pulley fixing screw on the front frame 
side or on the rear frame side.
5) Tighten the mirror base drive pulley fixing screw. 
<Adjustment specification>
La = Lb
6) Execute the main scanning direction (FR) distortion balance 
adjustment previously described in 2) again.
(4) Sub scanning direction (scanning direction) distortion 
adjustment
When there is no skew copy in the mirror base scanning direction and 
there is no horizontal error (right angle to the scanning direction), the 
adjustment can be made by adjusting the No. 2/3 mirror base unit rail 
height.
Before performing this adjustment, be sure to perform the horizontal 
image distortion adjustment in the laser scanner section. 
This adjustment must be performed in the following cases:
•When the mirror base wire is replaced.
•When the copy lamp unit or No. 2/3 mirror unit is replaced. 
•When the mirror unit rail is replaced or moved.
•When a following copy is made.
Lb
La
Original
Copy
Paper exit 
direction
Fit the paper edge and
 the glass holding plate edge. 
A3 (11" x 17") white paper
Glass holding plate
Allow a little space. 
Paper exit direction
La: Lead edge black background width
Lb: Rear edge black background width
A
B
Rear side
Front side
When La < Lb
Turn the mirror base drive pulley on the front frame side in the 
arrow direction A. 
(Do not move the mirror base drive pulley shaft.)
When La > Lb
Turn the mirror base drive pulley on the rear frame side in the 
arrow direction A. 
(Do not move the mirror base drive pulley shaft.)
Original
Copy A
Copy B
MX-M182 ADJUSTMENT 6-7
1) Making of a test sheet 
Make test sheet by drawing parallel lines at 10mm from the both 
ends of A3 (11" x 17") white paper as shown below. (These lines 
must be correctly parallel to each other.)
2) Make a normal (100%) copy of the test sheet on A3 (11" x 17") 
paper. (Fit the paper edge with the glass holding plate edge.)
3) Measure the distances (La, Lb, Lc, Ld) at the four corners as shown 
below. 
When La = Lb and Lc = Ld, no need to perform the procedures 4) and 5).
4) Move the mirror base F rail position up and down (in the arrow 
direction) to adjust. 
Note: Do not adjust the rail on the rear side. 
If the rail on the rear side is adjusted, an error may occur. 
Only the rail on the front side can be adjusted.
<Adjustment specification>
La = Lb, Lc = Ld
5) After completion of adjustment, manually turn the mirror base drive 
pulley, scan the mirror base A and mirror base B fully, and check that 
the mirror bases are not in contact with each other. 
*
If the mirror base rail is adjusted to extreme, the mirror base may 
contact the frame or original glass. Be careful to avoid this.
(5) Main scanning direction (FR direction) magnification 
ratio adjustment (SIM 48-1)
Note:Before performing this adjustment, be sure to check that the CCD 
unit is properly installed.
1) Put a scale on the original table as shown below.
2) Execute SIM 48-1.
3) After completion of warming up, shading is operated and the current 
correction value of the main scanning direction magnification ratio is 
displayed on the screen. 
4) Enter the set values of the items of F and R, and press [START] key. 
The correction values are saved and a copy is made.
10mm
10mm
10mm
10mm
Parallel line
White paper
Parallel line
La
Lb
Ld
Lc
Paper exit 
direction 
When La > Lb
Shift the mirror base B rail upward by the half of the
difference of La - Lb.
When La < Lb
Shift the mirror base B rail downward by the half of the
difference of Lb - La.
Example: When La = 12mm and Lb = 9mm, shift the mirror
base B rail upward by 1.5mm.
When Lc > Ld
Shift the mirror base B rail downward by the half of the
difference of Lc - Ld.
When Lc < Ld
Shift the mirror base B rail downward by the half of the
difference of Ld - Lc.
When moving the mirror base rail, hold the mirror base rail
with your hand.
Sim48-1 COPY MAG.
1:F-R
2:SCAN
     [      1-  99]
50
 
50 
50
MX-M182 ADJUSTMENT 6-8
<Adjustment specification>
Note:  A judgment must be made with 200mm width, and must not be 
made with 100mm width.
(6) Sub scanning direction (scanning direction) 
magnification ratio adjustment (SIM 48-1, SIM 48-5)
a. OC mode in copying (SIM48-1)
Note: Before performing this adjustment, be sure to check that the CCD 
unit is properly installed. 
1) Put a scale on the original table as shown below, and make a normal 
(100%) copy.
2) Compare the scale image and the actual image. If necessary, 
perform the following adjustment procedures. 
3) Execute SIM 48-1.
4) After completion of warming up, shading is operated and the current 
correction value of the sub scanning direction magnification ratio is 
displayed on the screen.
5) Select [2.SCAN] mode with the cross cursor.
6) Enter the set value and press the start key.
The set value is stored and a copy is made.
<Adjustment specification>
b. RSPF sub scanning direction magnification ratio (SIM48-5)
Note:
•Before performing this adjustment, be sure to check that the CCD unit is 
properly installed.
•Before performing this adjustment, the OC mode adjustment in copying 
must be completed.
1) Put a scale on the original table as shown below, and make a normal 
(100%) copy to make a test chart.
Note:Since the printed copy is used as a test chart, put the scale in 
parallel with the edge lines.
2) Set the test chart on the SPF and make a normal (100%) copy. 
3) Compare the scale image and the actual image. If necessary, 
perform the following adjustment procedures. 
4) Execute SIM 48-5.
5) After warm-up, shading is performed.
6) Check to confirm that the RSPF (SIDE1) mode is selected with the 
cross cursor.
7) Enter the set value and press the start key.
The set value is stored and a copy is made. 
<Adjustment specification>
* "RSPF (SIDE2)" is displayed only when the RSPF is installed.
(7) Off center adjustment (SIM 50-12)
a. OC mode (SIM50-12)
1) Make a test chart as shown below and set it so that its center line is 
fit with the original guide center mark.
* To make a test chart, draw a line on A3 or 11" x 17" paper at the center 
in the paper transport direction.
2) Make a normal copy from the manual paper feed tray, and compare 
the copy and the test chart.
If necessary, perform the following adjustment procedures. 
3) Execute SIM 50-12. 
Adjustment mode
SIM
Display 
text array
 Set 
value
Specifi-
cations
Set 
range
Main scanning 
direction magnifi-
cation ratio
48-1
F-R
+1 
 
+0.1%
-1 
 
0.1%
Normal ± 
1.0%
1 - 99
Adjustment mode
SIM
Display 
text array
Set 
value
Specifi-
cations
Set 
range
Sub scanning 
direction 
magnification ratio 
OC mode
48-1
SCAN
+1 
 
+0.1%
-1 
 
0.1%
Normal ± 
1.0%
1 - 99
Sim48-1 COPY MAG.
1:F-R
2:SCAN
     [      1-  99]
50
 
50 
50
Sim48-1 COPY MAG.
1:F-R
2:SCAN
     [      1-  99]
50 
50
 
50
Adjustment mode
SIM
Display 
text array
Set 
value
Specifi-
cations
Set 
range
Sub scanning 
direction 
magnification 
ratio
(Front surface)
48-5
RSPF
(SIDE1)
+1 
 
+0.1%
-1 
 
0.1%
Normal ± 
1.0%
1 - 99
Sub scanning 
direction 
magnification 
ratio
(Back surface)
RSPF
(SIDE2)
Sim48-5 (R)SPF ZOOM
1:RSPF(SIDE1)
2:RSPF(SIDE2)
     [      1-  99]
50
 
50 
50
Center
Original guide
Copy paper 
(A3 or 17" x 11")
MX-M182 ADJUSTMENT 6-9
4) After completion of warming up, shading is performed and the 
current off-center adjustment value is displayed on the LCD.
5) Enter the set value and press the start key.
The set value is stored and a copy is made.
<Adjustment specification>
C. Image density adjustment
(1) Copy mode (SIM 46-2)
1) Set a test chart (UKOG-0162FCZZ) on the OC table as shown 
below.
2) Put several sheets of A3 or 11" x 17" white paper on the test chart. 
3) Execute SIM 46-2.
4) After completion of warming up, shading is performed, and the 
current density level is displayed on the LCD. 
Use the cross cursor to select a mode.
5) Change the set value with the 10-key to adjust the copy image 
density.
6) Make a copy and check that the specification below is satisfied.
<Adjustment specification>
Adjustment 
mode
SIM
Display 
text array
Set value
Specifi-
cations
Set 
range
Document off-
center (OC 
mode)
50-12
OC
+1 
 
Shifted to R 
side by 
+0.mm.
-1 
 
Shifted to L 
side by 
0.1mm.
Center ± 
2.0%
1 - 99
Sim50-12 ORG. CENTER
1:OC
2:SPF(SIDE1)
3:SPF(SIDE2)
     [      1-  99]
50
 
50
50 
50
Density 
mode
Display 
text 
array
Expo-
sure 
level
Sharp Gray 
Chart output
Set value
Set 
range
Auto-
matic
AE
-
"2" is slightly 
copied. 
The greater the set 
value is, the darker 
the density is.
The smaller the set 
value is, the lighter 
the density is. 
1 - 99
Text
TEXT
3
"3" is slightly 
copied. 
Photo 
(Error 
diffu-
sion)
PHOTO
1
3
"2" is slightly 
copied.
Photo 
(Dither)
PHOTO
2
3
"2" is slightly 
copied.
Toner 
save 
(Text)
TEXT 
(TS)
3
"3" is slightly 
copied.
Toner 
save 
(Auto-
matic)
AE(TS)
-
"2" is slightly 
copied.
UKOG-0162FCZZ
Sim46-1 EXP LEVEL
1:AE
2:TEXT
3:PHOTO 1
1/2     [      1-  99]
50
 
50 
50 
50
Sim46-1 EXP LEVEL
4:PHOTO 2
5:TEXT(TS)
6:AE(TS)
2/2     [      1-  99]
50
 
50 
50 
50
Page of 127
Display