6.4 PUNCHING
OPERATIONS
After installing the correct die set in your SmartPunch, you are ready to begin punching. The following
sections indicate how to activate the machine. Read these sections completely and become familiar
with the various machine and Die Set components.
sections indicate how to activate the machine. Read these sections completely and become familiar
with the various machine and Die Set components.
The POWER LED should be illuminated. If not, apply power with the Power On/Off (I/O) switch located
at the front of the SmartPunch module.
at the front of the SmartPunch module.
PUNCH ENABLED: You activate the punch by using the Multi-function printer interface screen.
Once punch is enabled, the LED will remain illuminated and the punch will remain enabled for one full
minute after the run has ended. After that time, the system will default to the bypass mode and the next
run will not be punched.
minute after the run has ended. After that time, the system will default to the bypass mode and the next
run will not be punched.
CLOSE DOOR and PAPER JAM: If either of these LED’s are on, no bypass and no punch can occur
until these areas have been checked and corrected.
until these areas have been checked and corrected.
CHIP TRAY FULL/OUT and CHECK DIE SET: If either of these LED’s is on, you can run in bypass
mode but not punch mode.
mode but not punch mode.
CHIP TRAY FULL/OUT: If this LED is flashing the Chip Tray is FULL. If this LED is shinning solid, the
Chip Tray is OUT.
Chip Tray is OUT.
POWER: If this LED is not on, paper can not run through the GBC SmartPunch in either bypass or
punch mode. The paper will jam entering the GBC SmartPunch.
punch mode. The paper will jam entering the GBC SmartPunch.
6.5 PAPER CHIP DRAWER
The paper chip drawer for your SmartPunch is located at the front of the machine’s base. The drawer
should be periodically pulled out and emptied. The SmartPunch incorporates microprocessor
technology to inform the operator when the Chip Tray needs to be emptied. When the Punch has cycled
4000 times, the Check Chip Tray LED will begin to flash on and off. You may continue to use the
SmartPunch for a short period longer if you wish, but it is not recommended.
should be periodically pulled out and emptied. The SmartPunch incorporates microprocessor
technology to inform the operator when the Chip Tray needs to be emptied. When the Punch has cycled
4000 times, the Check Chip Tray LED will begin to flash on and off. You may continue to use the
SmartPunch for a short period longer if you wish, but it is not recommended.
You must empty the Chip Tray with the Power On so that the sensors are able to identify this action.
This will ensure that the LED will reset itself.
This will ensure that the LED will reset itself.
BINDER SIDE
FINISHER SIDE
B
A
46
6.6 SERVICE
• Should your SmartPunch require service contact your local authorized service representative.
• There are NO user-serviceable parts inside the machine. To avoid potential personal injury and/or
property damage, DO NOT REMOVE THE MACHINE’S COVER.
• It is recommended that your SmartPunch receives preventative maintenance every 6 months or
sooner depending on usage.
6.7 PROBLEM SOLVING, OPERATOR LEVEL SMARTPUNCH
Problem Probable
Cause
No power, won’t punch
Power cord not attached to back of machine or not
properly plugged into the wall
Power On/Off Switch not activated
properly plugged into the wall
Power On/Off Switch not activated
Die Set will not come out using a
moderate pull
moderate pull
The Die Set is in partial cycle. Turn the Die Set knob to
the HOME position. The Die Set should now slide out
easily.
Also see PAPER JAMS.
the HOME position. The Die Set should now slide out
easily.
Also see PAPER JAMS.
47
6.8 PAPER
JAM
48
7. SPECIFICATIONS
115V MACHINES
Speed
Up to 110 sheets per minute
Punch Sheet Size
8 ½” x 11”
Punch Edge
11” edge of 8.5” x 11”
Paper Stock
20 lb bond to
80 lb cover
Paper Bypass Mode
Sheet size
Paper sizes and stocks
same as multi-function printer
Punch Capacity
Single Sheet
Power Supply
115VAC
60 Hz
Single Phase
Amps – 3.0 A
Watts – 340W
BTU’s/Hour – 1160 BTU/HR
Safety
CSA certified to UL
and CSA standards
Dimensions
12”(W)
38.5” (H)
28.5” (D)
28.5” (D)
Weight 154
lbs.
Shipping Weight
235 lbs.
Manufactured
Made in the U.S.A.
Specifications are subject to change without notification.