Sharp MX-B382 (serv.man4) Handy Guide ▷ View online
Firmware & Print Driver Revision
SHARP
Document Solution Centre
33
Engine Firmware:
Firmware ROM
MX-B382
MX-B382P
ICU Main
02.00.f2
01.02.w2
ICU Boot
01.00.f2
01.00.w0
PCU
01.01.f2
01.01.f2
SCU
01.02.F0
OPU
01.00.W0
Desk
(MX-CSX1/2)
01.01.F0
Finisher
(MX-FN12)
01.03.F0
Fax Main
(MX-FXX3)
01.03.P2
Data Security Kit
(MX-FR26U)
02.01.fd
Data Security Kit
(MX-FR31U)
E-Manual
01.30.f2
01.10.w2
Print Driver:
Driver
Windows 32bit OS
XP, 2003, 2008, Vista, 7
Windows 64bit OS
XP, 2003, 2008, Vista, 7
MX-B382
PCL5e *
01.04.03.01
[WHQL]
N/a
PCL6
01.04.08.01
[WHQL]
01.04.08.01
[WHQL]
PS
01.04.07.01
[WHQL]
01.04.07.01
[WHQL]
PPD
1.0.0.13
[WHQL]
1.0.0.13
[WHQL]
PC-FAX
3.6.6.4
3.6.6.4
XPS **
01.02.32.01
01.02.32.01
MX-B382P
PCL5e *
01.04.05.01
]
N/a
PCL6
01.04.14.01
01.04.14.01
PS
01.04.14.01
01.04.14.01
PPD
1.0.0.14
1.0.0.14
]
XPS **
01.02.32.01
01.02.32.01
Notes: * Not supported on Windows 7 or Server 2008(R2).
** Supports Windows Vista only.
For the latest Firmware and Print Driver version(s),
please refer to the SHARP Support Website.
Test Simulations
34
SHARP
Document Solution Centre
The following pages contain information regarding test simulations. For a detailed description for
each test simulation, please refer to the MX-B382 or MX-B382P Service Manual.
MX-B382:-
each test simulation, please refer to the MX-B382 or MX-B382P Service Manual.
MX-B382:-
Entry Code:
MX-B382P:-
Entry Code:
Key Function List [MX-B382P]:
Used to shift the menu to the one-step
upper stage menu in the simulation
mode.
upper stage menu in the simulation
mode.
Used to fix the selected button, to
enter a numeral, * key, # key, or C
key, and to execute the simulation
operation.
enter a numeral, * key, # key, or C
key, and to execute the simulation
operation.
Up
&
Down
Used to scroll upward. (Item selection)
Used to switch to the next screen.
Used to switch to the next screen.
Used to scroll downward (Item
selection) and switch to the previous
screen.
selection) and switch to the previous
screen.
Used to enter the simulation mode
and switch between the "10KEY"
mode (value input) and the "MAIN"
mode (item selection).
and switch between the "10KEY"
mode (value input) and the "MAIN"
mode (item selection).
Used to enter the simulation mode,
and to cancel the simulation mode.
and to cancel the simulation mode.
Left
&
Right
Used to select an item or a button on
the Simulation menu in the "MAIN"
mode.
Also used to select a numeral value,*
key, # key, or C key on the Simulation
screen in the "10KEY" mode.
the Simulation menu in the "MAIN"
mode.
Also used to select a numeral value,*
key, # key, or C key on the Simulation
screen in the "10KEY" mode.
Used to enter the simulation mode.
Used to fix the simulation number,
adjustment values, or set values
after entering them
adjustment values, or set values
after entering them
To enter a Simulation Code:
Use the Entry Code sequence as described above.
Press the key to change from MAIN mode to 10KEY mode.
Using the SCROLL key , select the required number and press the OK.
Example: To enter Sim 49:-
Scroll to 4 and select OK
Then scroll to 9 and select OK.
To fix the simulation number, press the shortcut key
Test Simulations
SHARP
Document Solution Centre
35
1
Scanner Self Test
[MX-B382]
1
Scanner operations test
2
Scanner sensor check
5
Scanner unit and control circuit check
2
RSPF Self Test
[MX-B382]
1
SPF ageing test.
2
SPF sensor check
3
SPF output check (motor, clutch, solenoid)
3
Finisher Operation & Test
2
Finisher sensor check
3
Finisher output check
10
Finisher adjustment
4
Desk / LCC Operation & Test
2
Desk sensor check
3
Desk output check
5
Desk clutch operation check
5
Lamp Operation & Test
1
LCD/LED test
2
Heater lamp load check
5
Lamp Operation & Test
3
Copy lamp check
[MX-B382]
4
Discharge lamp check
6
System Load Operation & Test
1
Feed output check
2
Fan load check
3
Transfer operation check
6
Fuser Separation operation check
51
Force DV/Fuser initial fuse (open/cut)
7
Device Aging Operation & Test
1
Ageing test setting
6
Interval ageing cycle timer set up
8
Warm up time display setting
12
Document reading aging setting
[MX-B382]
8
High Voltage Operation & Test
1
Developer bias setting and output
2
MHV/Grid setting and output
6
Transfer setting and output
9
Duplex Operation & Test
2
ADU sensor check
3
ADU load & output check
10
Toner Motor Operation & Test
1
Toner motor operation check
13
U1 Clear / Cancel
--
Trouble cancel (U1 trouble).
14
Clear / Cancel
--
Trouble cancel (excluding U2/PF trouble).
16
U2 Clear / Cancel
--
U2 trouble cancel
17
PF Clear / Cancel
--
PF trouble cancel
21
Maintenance Cycle Configuration
1
Maintenance cycle setting
22
Data Output & Check
1
Counter data display
2
Jam/trouble counter display
3
Jam history data display
4
Trouble code history data display
5
ROM version display
6
Data print mode
8
Document feed and output counter display
9
Paper feed counter display
10
Machine system display
11
Fax counter display
[MX-B382]
12
RSPF/DSPF jam history display
[MX-B382]
13
Process cartridge counter display
19
Network scan counter display
[MX-B382]
25
Toner usage estimator data display
90
System setting list print
23
Data Print Mode & Check
2
Print jam/Trouble data print mode
80
Data print mode (paper feed)
24
Data Counter & Clear
1
Jam/trouble counter clear
2
Paper feed counter clear
3
Document feed & output counter clear
4
Maintenance counter clear
5
Developer counter clear
6
Copy Counter clear
[MX-B382]
7
Drum correction counter clear
9
Print & other counter clear
10
Fax counter clear
[MX-B382]
15
Network scan counter clear
[MX-B382]
Test Simulations
36
SHARP
Document Solution Centre
24
Data Counter & Clear
25
Toner usage estimator counter clear
30
Administrator password initialisation
31
Service password initialisation
34
Initialise Sim 26-32 settings
25
DV Auto Adjustment & Monitor
1
Toner sensor monitor (Process drive)
2
Auto developer adjustment setting
26
Device Configuration
2
LCC size set-up
3
Auditor setup
[MX-B382]
6
Destination set-up
10
Network scanner trial mode
[MX-B382]
18
Toner save operation
30
CE mark control setup
32
System setting menu display setting
35
Trouble memory mode setting
38
Engine life over setting (Developer)
41
Pamphlet mode AMS operation
[MX-B382]
49
Copy mode setup (Postcard)
[MX-B382]
50
Function setting
52
Blank paper count mode setting
53
Enable/Disable auto calibration
[MX-B382]
54
Enable/Disable auto calibration for printer
65
Finisher alarm mode set-up
69
Toner near end setting
73
Poster enlargement adjustment
[MX-B382]
74
OSA Trial Mode setting
78
Remote panel operation password setting
30
Sensor Operation & Test
1
Main unit sensor check
2
Tray sensor check (main)
40
Bypass Operation & Adjustment
2
Bypass tray width adjustment
7
Bypass tray width detection manual setting
41
OSS Adjustment
[MX-B382]
1
Document sensor operation check
2
Document sensor output setup
3
Document sensor output display
43
Fuser Setting & Adjustment
1
Fuser temperature setup (Paper)
4
Fuser temperature. setup for each mode
20
Fuser correction for low temp/humidity
21
Fuser correction for high temp/humidity
22
L/L correction for fuser temperature setting
23
H/H correction for fuser temp. setting
43
Fuser Setting & Adjustment
24
Fuser temperature reset
44
Process Control Data
1
Process control mode setting
2
Process control Gain Adjustment
4
Process control initial density setup
6
Process control correction (force)
9
Process control data display
12
DM data, patch/base data display
14
Temp.& humidity output data
16
Toner control output data display
21
Half tone process control registration
22
Half tone process control patch result
24
Half tone correction data result display
25
Initial half tone correction data display
26
Half tone process control correct execution
27
Half tone process control correction clear
28
Process control timing (On/Off) setting
29
Enable/disable half tone correction (job)
37
Image density (DVB) adjust setting
43
DV unit installation monitor
46
Image Density Adjustment
[MX-B382]
2
B/W copy density adjustment
[MX-B382]
4
Colour scanner density adjustment.
5
B/W scanner density adjustment.
8
Colour scanner balance adjustment.
9
SPF exposure adjustment.
16
Engine balance manual adjustment B/W.
19
B/W auto exposure mode setup.
21
Engine density balance adjustment
23
Engine maximum density adjustment.
24
Engine half tone auto adjustment.
32
Document background density adjustment
37
B/W image create adjustment.
39
Fax Image send sharpness adjustment.
40
Fax mode exposure adjust (All modes).
41
Fax mode exposure adjust (Normal).
42
Fax mode exposure adjust (Fine Text).
43
Fax mode exposure adjust (Super Fine).
44
Fax mode exposure adjust (Ultra Fine).
45
Fax mode exposure adjustment (600dpi).
47
JPEG compression rate setting.
51
Heavy paper mode gamma adjustment.
60
Sharpness adjustment (colour auto mode).
61
Area separation recognition setting.
62
ACS operating condition setting.
63
Copy low density adjustment.
74
Copy colour balance adjustment.
46
Print Density Adjustment
[MX-B382P]
21
Engine density balance adjustment
Click on the first or last page to see other MX-B382 (serv.man4) service manuals if exist.