Sharp MX-B201D (serv.man6) Service Manual ▷ View online
MX-FX12 FAX SOFT SWITCH 2 - 9
S
W
30
1
Report output
when canceling
when canceling
Used to set whether the user cancel report is outputted or not when
send is canceled during document send.
send is canceled during document send.
Not output
0
1: Output
0: Not output
2
Inhibited to use
0
3
0
4
0
5
Default data,
sender print
sender print
Used to set whether sender information (registered in the sender
registration), sending date, and time are printed on the upper edge
of send document or not.
registration), sending date, and time are printed on the upper edge
of send document or not.
ON
1
1: ON
0: OFF
6
Report output
(in anti junk set.)
(in anti junk set.)
Use to whether the activity report is printed when anti-junk function
operates.
operates.
Print inhibited
0
1: Print
0: Print inhibited
7
Date/sender print
position setup
position setup
Used to set whether date/sender information is printed inside the
document area or outside the document area.
document area or outside the document area.
Outside of
document
0
1: Inside of document
0: Outside of document
8
Inhibited to use
0
S
W
31
1
Report output
(in transmission)
(in transmission)
Used to set whether communication report is outputted or not after
completion of sending (excluding sequential broadcast and
sequential send request).
completion of sending (excluding sequential broadcast and
sequential send request).
Only when
transmission is
failed.
1
Refer to User program
“PRINT SELECTION”.
When a value outside the
set range is set, the initial
value is set.
“PRINT SELECTION”.
When a value outside the
set range is set, the initial
value is set.
Bit No.
1
2
2
Print inhibited
0
0
0
All print
0
1
Only when transmission is
failed.
failed.
1
0
3
Report output
(In broadcast and
sequential send
request)
(In broadcast and
sequential send
request)
Used to set whether communication report is outputted or not after
completion of sending (sequential broadcast and sequential send
request).
completion of sending (sequential broadcast and sequential send
request).
All print
0
Refer to User program
“PRINT SELECTION”.
When a value outside the
set range is set, the initial
value is set.
“PRINT SELECTION”.
When a value outside the
set range is set, the initial
value is set.
Bit No.
3
4
4
Print inhibited
0
0
1
All print
0
1
Only the address to which
transmission is failed
transmission is failed
1
0
5
Report output
(in reception)
(in reception)
Used to set whether communication report is outputted or not in
reception.
reception.
Print inhibited
0
Refer to User program
“PRINT SELECTION”.
When a value outside the
set range is set, the initial
value is set.
“PRINT SELECTION”.
When a value outside the
set range is set, the initial
value is set.
Bit No.
5
6
6
Print inhibited
0
0
0
All print
0
1
Only in error
1
0
7
Contents of send
document are
printed in memory
send
document are
printed in memory
send
Used to set whether part of send document is printed on the
communication report or not in memory send.
communication report or not in memory send.
Only the address
to which
transmission is
failed
1
Refer to User program
“PRINT SELECTION”.
When a value outside the
set range is set, the initial
value is set.
“PRINT SELECTION”.
When a value outside the
set range is set, the initial
value is set.
Bit No.
7
8
8
Print inhibited
0
0
0
All print
0
1
Only the address to which
transmission is failed
transmission is failed
1
0
S
W
32
1
Distinctive ringing
(U.S.A., Canada,
Australia, New
Zealand)
(U.S.A., Canada,
Australia, New
Zealand)
Used to set the ringing pattern as FAX reception.
OFF
0
Refer to User program
“DISTINCTIVE RING”.
When a value outside the
set range is set, the initial
value is set.
*1: For U.S.A., Canada
“DISTINCTIVE RING”.
When a value outside the
set range is set, the initial
value is set.
*1: For U.S.A., Canada
only
Bit No.
1
2
3
4
2
OFF
0
0
0
0
0
Standard/ON
0
0
0
1
3
Pattern 1 *
1
1
0
0
0
0
Pattern 2 *
1
0
1
0
0
4
Pattern 3 *
1
1
1
0
0
0
Pattern 4 *
1
0
0
1
0
Pattern 5 *
1
1
0
1
0
5
Inhibited to use
0
6
Index print setup
Used to set whether the index is printed when outputting received
document or not.
document or not.
Not print
0
Refer to User program
“INDEX PRINT”.
“INDEX PRINT”.
1: Print
0: Not print
7
Inhibited to use
0
8
0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12 FAX SOFT SWITCH 2 - 10
S
W
33
1
Page number print
setup
setup
Used to set whether the page number is added to the sender
information print or not.
information print or not.
Yes
1
1: Yes
0: No
2
Inhibited to use
0
3
0
4
0
5
0
6
0
7
0
8
Reception data
duplex print
duplex print
Used to set whether duplex print of received data is made or not.
No
0
Refer to User program
“DUPLEX RCV”.
“DUPLEX RCV”.
1: Yes
0: No
S
W
34
1
Flash send wait
time (U.S.A.,
Canada, U.K.,
Netherlands,
Luxembourg,
Belgium, France,
Australia, New
Zealand: Inhibited
to use)
time (U.S.A.,
Canada, U.K.,
Netherlands,
Luxembourg,
Belgium, France,
Australia, New
Zealand: Inhibited
to use)
Used to set the time from off-hook to Flash send.
1sec.
0
Bit No.
1
2
0sec.
0
0
0.5sec.
0
1
2
1sec.
1
0
0
2sec.
1
1
3
Inhibited to use
0
4
0
5
Signal send level
Max.
Max.
Used to set the max. signal send level.
Binary input
Binary input
–8dBm
1
6
0
7
Bit No.
Set range
Set range
5
6
7
8
0 (0dBm) to 15 (–15dBm)
0
8
0
S
W
35
1
Cover function
default setup
default setup
Used to set whether cover is added as default or not.
When auto clear is made by pressing [Clear All] key, the machine
returns to this setting.
When auto clear is made by pressing [Clear All] key, the machine
returns to this setting.
No
0
1: Yes
0: No
2
Answering
machine
connection
machine
connection
Setting to make them connect telephone that has answering
machine function as external telephone, and unite answering
machine function to fax receiver function.
When an absent function of an external telephone is used, it sets it
to “ON”.
The setting simultaneously with the dial-in function is improper.
machine function as external telephone, and unite answering
machine function to fax receiver function.
When an absent function of an external telephone is used, it sets it
to “ON”.
The setting simultaneously with the dial-in function is improper.
ON
1
1: ON
0: Off
3
CI delete max.
OFF time
OFF time
Used to set the max. wait time between detection of CI signal
pulse (number of times) and detection of the next CI signal
pulse.
pulse (number of times) and detection of the next CI signal
pulse.
If CIK signal pulse is not detected within this time, the number of
calls up to that time is cleared.
calls up to that time is cleared.
5sec.
0
4
Bit No.
3
4
0
5sec.
0
0
10sec.
0
1
15sec.
1
0
20sec.
1
1
5
Answering
machine call
number setting
machine call
number setting
Used to set the number of calls to switch to auto receive when
answering telephone is not called in when the receive mode is set
to the answering telephone connection mode.
Setting is made in binary input.
Binary input
answering telephone is not called in when the receive mode is set
to the answering telephone connection mode.
Setting is made in binary input.
Binary input
5 times
0
6
1
7
0
Bit No.
Set range
Set range
5
6
7
8
0 to 15 times
8
1
S
W
36
1
CNG detection
completion time
completion time
Used to set the time for completion of CNG signal/mute detection in
the answering telephone connection mode.
Count is made from the last call signal.
the answering telephone connection mode.
Count is made from the last call signal.
45sec.
0 When a value outside the
set range is set, the initial
value is set.
value is set.
2
0
3
1
4
Setting is made in binary input.
0
5
Binary input
1
6
Bit No.
Set range
Set range
1
2
3
4
5
6
7
8
1 to 255sec.
1
7
0
8
1
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12 FAX SOFT SWITCH 2 - 11
S
W
37
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
38
1
Protocol monitor
Used to set whether communication protocol result is printed or not
after completion of communication.
after completion of communication.
Not output
0
Bit No.
1
2
2
Not output
0
0
0
Not output
0
1
Output
1
0
Output only in an error
1
1
3
Protocol monitor
save
save
Used to set whether the protocol monitor of the last communication
is saved or not. When set to “Saved,” the previous protocol monitor
can be printed with SIM66-21.
is saved or not. When set to “Saved,” the previous protocol monitor
can be printed with SIM66-21.
Yes
1
1: Yes
0: No
4
Inhibited to use
0
5
Flash send time
(U.S.A., Canada,
U.K., Netherlands,
Luxembourg,
Belgium, France,
Australia, New
Zealand: Inhibited
to use)
(U.S.A., Canada,
U.K., Netherlands,
Luxembourg,
Belgium, France,
Australia, New
Zealand: Inhibited
to use)
Used to set the Flash send time.
90ms
0
Bit No.
5
6
90ms
0
0
6
180ms
0
1
0
270ms
1
0
360ms
1
1
7
Transfer function
Used to set whether transfer function is enabled or not.
Allow
1
1: Allow
0: Inhibit
8
Inhibited to use
0
S
W
39
1
Threshold of
electric current in
fax starting
electric current in
fax starting
Setting of amount of current of line that machine detects at auto
dialing. When it is fewer than this value, the machine is not sent.
dialing. When it is fewer than this value, the machine is not sent.
>= 12mA
(LVCS:1)
(LVCS:1)
0
2
Bit No.
1
2
3
0
Current is disregarded.
0
0
0
>= 12mA (LVCS:1)
0
0
1
3
>= 15mA (LVCS:2)
0
1
0
1
>= 18mA (LVCS:3)
0
1
1
>= 21mA (LVCS:4)
1
0
0
4
DTMF signal send
time
time
Used to set DTMF signal send time.
110ms
0
When a value outside the
set range is set, the initial
value is set.
set range is set, the initial
value is set.
Setting is made in binary input by the increment of 10ms.
5
Binary input
1
Bit No.
Set range
Set range
4
5
6
7
8
60 to 310ms
(North America)
70 to 310ms
(Except North America)
10ms unit
6
0
7
1
8
1
S
W
40
1
Number of times
of recall in error
of recall in error
Used to set the number of times of recall when a communication
error occurs.
error occurs.
1 times
0 Refer to User program
“RECALL TIMES (LINE
ERROR)”.
When a value outside the
set range is set, the initial
value is set.
ERROR)”.
When a value outside the
set range is set, the initial
value is set.
2
0
3
Setting is made in binary input.
0
4
When set to 0, recall is not made.
0
5
Set range
0
0 to 1 times
(U.S.A., Australia, New Zealand)
0 to 5 times
(U.K., Germany, France, Middle East)
0 to 9 times
(Singapore, Malaysia, India, Indonesia, Thailand, Vietnam)
0 to 3 times
(Hong Kong, China)
6
0
7
0
8
1
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12 FAX SOFT SWITCH 2 - 12
S
W
41
1
Number of times
of recall in busy
of recall in busy
Used to set the number of times of recall when busy tone is
detected during transmission.
detected during transmission.
2 times
0 Refer to User program
“RECALL TIMES (BUSY)”.
When a value outside the
set range is set, the initial
value is set.
When a value outside the
set range is set, the initial
value is set.
2
0
3
Setting is made in binary input.
0
4
When set to 0, recall is not made.
0
5
Set range
0
0 to 14times
(U.S.A.)
0 to 10 times
(U.K., Germany, France, Middle East)
0 to 9 times
(Singapore, Malaysia, India, Indonesia, Thailand, Vietnam)
0 to 3 times
(China, Hong Kong)
6
0
7
1
8
0
S
W
42
1
Direct send recall
(U.S.A., Canada)
(U.S.A., Canada)
Used to set whether direct send recall wait is allowed or not.
Allow
0
1: Inhibit
0: Allow
2
FAX receive auto
select by CNG
detection
select by CNG
detection
Used to set whether FAX receive auto select is enabled or not when
CNG signal is detected with external telephone used.
CNG signal is detected with external telephone used.
Allow
1
Refer to User program
“FAX SIGNAL AUTO
RECEIVE”.
“FAX SIGNAL AUTO
RECEIVE”.
1: Allow
0: Inhibit
3
Auto receive
select in
answering
telephone
connection mode
select in
answering
telephone
connection mode
Used to set whether auto receive select function in answering
telephone connection mode is enabled or not.
telephone connection mode is enabled or not.
OFF
0
Refer to Main menu “AM
MODE”.
MODE”.
1: ON
0: OFF
4
Inhibited to use
0
5
0
6
0
7
0
8
0
S
W
43
1
V.34 mode
function
function
Used to set whether V.34 mode is enabled or not as a capacity of
own machine in send/receive.
own machine in send/receive.
ON
1
1: ON
0: OFF
2
Inhibited to use
0
3
0
4
V.34 receive
symbol speed
mask
symbol speed
mask
Used to set symbol speed mask in V.34 receive.
3429
1
When a value outside the
set range is set, the initial
value is set.
set range is set, the initial
value is set.
Bit No.
4
5
6
5
2400
0
0
0
0
2743
0
0
1
2800
0
1
0
6
3000
0
1
1
1
3200
1
0
0
3429
1
0
1
7
Inhibited to use
0
8
0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
Click on the first or last page to see other MX-B201D (serv.man6) service manuals if exist.