DOWNLOAD Sharp MX-B201D (serv.man6) Service Manual ↓ Size: 1.19 MB | Pages: 56 in PDF or view online for FREE

Model
MX-B201D (serv.man6)
Pages
56
Size
1.19 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual MX-FX12
File
mx-b201d-sm6.pdf
Date

Sharp MX-B201D (serv.man6) Service Manual ▷ View online

MX-FX12  FAX SOFT SWITCH  2 - 4
S
W
7
4
Dial tone 
monitoring time
Used to set the monitoring time when detecting dial tone.
5sec.
0
1: 10sec.
0: 5sec.
5
Dial tone ON/OFF 
detection time 
upper limit 
(Intermittent 
detection)
Used to set the upper limit time for detection of dial tone when the 
dial tone detection is set to “YES” and the kind of the dial tone 
detection is set to “Intermittent.”
If a dial tone is detected for more than this upper limit time, it is not 
considered as a dial tone.
700ms
0
1: 400ms
0: 700ms
6
Max. length of 
reception
Used to set max. length of reception for long document.
1.5m
0
1: No limit
0: 1.5m
7
Destination 
display time when 
one-touch key is 
pressed
Used to set the time from displaying the destination to the next 
operation in one-touch dial or reduction dial.
2sec.
0
When a value outside the 
set range is set, the initial 
value is set.
Bit No.
7
8
8
2sec.
0
0
0
4sec.
0
1
6sec.
1
0
S
W
8
1
Memory 
transmission/
direct transmission 
default setup
Used to set whether memory send is ON or direct send is made 
(OFF) in the memory mode when pressing [Clear All] key or auto 
clear.
Memory 
transmission
0
1: Direct transmission
0: Memory transmission
2
Inhibited to use
0
3
Dial tone ON/OFF 
detection time 
upper limit 
(Option)
Used to set the upper limit time for detection of dial tone.
This is a setting to enhance SW7-5.
Follows SW7-5.
0
1: SW7-5=0:1000ms 
SW7-5=1:1200ms
0: Follows SW7-5.
4
Quick online send Used to set whether quick online send function is enabled or not.
When set to 0, send in memory mode ON is made in memory send.
When set to 1, send in memory mode ON is made in quick online 
send.
Yes
1
1: Yes
0: No
5
Remote select 
function
Used to set whether remote reception function is enabled or not.
Yes
1
Refer to User program 
“REMOTE RECEPTION 
SELECT”.
1: Yes
0: No
6
Number of 
checking CNG
Used to set the number of times of CNG detection for judgment of 
detection.
3 times
0
When a value outside the 
set range is set, the initial 
value is set.
7
Binary input
1
Bit No.
6
7
8
8
Set range
1 to 4 times
1
S
W
9
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
10
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
11
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12  FAX SOFT SWITCH  2 - 5
S
W
12
1
Call time setup in 
automatic 
transmission
(T0 timer setup)
Used to set call time in automatic send.
45sec.
0
When a value outside the 
set range is set, the initial 
value is set.
Setting is made by binary input of N into “(5sec. x N) + 30sec.” in 
the increment of 5sec.
2
Binary input
0
Bit No.
1
2
3
4
3
Set range
30 to 45sec. (China, Hong Kong)
1
30 to 60sec. (Singapore, 
Indonesia, Thailand, India)
4
30 to 75sec. (Excluding the avobe)
1
5
Inhibited to use
0
6
CI detection
Used to set the detection frequency of CI signal (call signal).
4 sine wave
0
When a value outside the 
set range is set, the initial 
value is set.
Bit No.
6
7
7
4  sine  wave
0
0
0
3 sine wave
1
0
2 sine wave
0
1
8
Inhibited to use
0
S
W
13
1
Inhibited to use
0
2
0
3
Ringing volume
Used to set the ringing volume when call-in.
Medium
1
Refer to User program 
“RINGER VOLUME”.
Bit No.
3
4
Silent
0
0
4
Small
0
1
0
Medium
1
0
Large
1
1
5
Speaker volume in 
DTMF send
Used to set the volume of transmission and DTMF sound from the 
speaker when SPEAKER key is pressed.
Medium
1
Bit No.
5
6
Not used
0
0
6
Small
0
1
0
Medium
1
0
Large
1
1
7
Inhibited to use
0
8
0
S
W
14
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
15
1
Busy tone 
detection time 
(Lower limit)
Used to set the lower limit of busy tone detection time (ON time).
250ms
0
1: 350ms
0: 250ms
2
Busy tone 
detection time 
(Upper limit)
Used to set the upper limit of busy tone detection time (ON time).
1000ms
0
1: 650ms
0: 1000ms
3
Busy tone 
detection time 
(Lower limit 2)
Used to set the lower limit 2 of busy tone detection time (ON time).
Follows SW15-1. 0
1: 150ms
0: Follows SW15-1.
4
Signal send level
Used to set signal send level from MODEM.
–12dBm
0 When a value outside the 
set range is set, the initial 
value is set.
5
Setting is made in binary input in the increment of 1dBm.
1
6
Binary input
1
7
Bit  No.
4
5
6
7
8
0
8
Set range
0 (0dBm) to 26 (–26dBm)
0
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12  FAX SOFT SWITCH  2 - 6
S
W
16
1
Inhibited to use
1
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
17
1
Inhibited to use
0
2
MH fixed (Except 
for SG3)
Used to set whether coding capacity is fixed to MH or not in 
communication other than SG3.
No
0
1: Yes
0: No (depending on the other 
party’s machine)
3
ECM MMR mode 
(Except for SG3)
Used to set whether MMR coding capacity is allowed or not in 
communication other than SG3.
Yes
1
1: Yes
0: No
4
ECM JBIG mode 
(Except for SG3)
Used to set whether JBIG coding capacity is allowed or not in 
communication other than SG3.
Yes
1
1: Yes
0: No
5
Inhibited to use
0
6
MH fixed (in SG3) Used to set whether coding capacity is fixed to MH or not in SG3 
communication.
No
0
1: Yes
0: No (depending on the other 
party’s machine)
7
ECM MMR mode 
(in SG3)
Used to set whether MMR coding capacity is allowed or not in SG3 
communication.
Yes
1
1: Yes
0: No
8
ECM JBIG mode 
(in SG3)
Used to set whether JBIG coding capacity is allowed or not in SG3 
communication.
Yes
1
1: Yes
0: No
S
W
18
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
19
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
Recording table 
automatic print
Used to set whether communication report is automatically 
outputted or not when the number of send/receive items which have 
not outputted yet on communication report reaches 50.
When set to 1, they are automatically outputted.
When set to 0, they are not outputted even the number of items 
reaches 50.
No
0
Refer to User program 
“AUTO LISTING”.
1: Yes
0: No
7
Inhibited to use
0
8
0
S
W
20
1
Line sound 
monitor range
Used to set line sound monitor range when line sound monitor 
function is used.
OFF
0
When a value outside the 
set range is set, the initial 
value is set.
Bit No.
1
2
2
OFF
0
0
0
Up to NSF signal send/
receive
0
1
All
1
0
3
Inhibited to use
0
4
0
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12  FAX SOFT SWITCH  2 - 7
S
W
20
5
Receivable 
memory capacity
Used to set the remained memory capacity for allowing call-in.
128Kbyte
0
The machine doesn’t arrive when it decreases more than this 
capacity.
1: 64Kbyte
0: 128Kbyte
6
Inhibited to use
0
7
0
8
0
S
W
21
1
Interval between 
completion of 
communication 
and the next call
Used to set the interval between completion of communication and 
the next call.
1sec.
0
2
0
3
Setting is made in binary input.
0
4
Binary input
0
5
Bit  No.
1
2
3
4
5
6
7
8
0
6
Set range
0 to 255sec.
0
7
0
8
1
S
W
22
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
23
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
24
1
Inhibited to use
0
2
0
3
Specified number 
reception (ANTI 
JUNK FAX)
Used to set whether the FAX receive rejection function is made 
valid or not for registered FAX numbers.
Not set.
0
Refer to Main menu “ANTI 
JUNK FAX”.
When a value outside the 
set range is set, the initial 
value is set.
4
Bit  No.
3
4
0
Not set.
0
0
Receive inhibit
0
1
5
Inhibited to use
0
6
Document output 
setup in reception
Used to set the document output procedure; whether all the 
received documents are collectively outputted after completion of 
reception or every page is outputted when it is received.
Output after 
reception of 
every page
0
1: Collective output after 
completion of reception
0: Output after reception of 
every page
7
Inhibited to use
0
8
Automatic 
reduction print
Used to set whether automatic reduction print is performed or not 
so that a document longer than the fixed size and smaller than the 
automatic reduction line number setting is printed on fixed size 
paper.
Allow
1
Refer to User program 
“AUTO RCV REDUCE”.
1: Allow
0: Inhibit
S
W
25
1
Minimum non-
divide reduce rate
The non-divide minimum reduce rate [%] = 100 - (3 x N)
N: 0 - 15 (Default: 10)
70% (N=10)
1
2
0
3
1
4
0
5
Inhibited to use
0
6
0
7
0
8
0
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
Page of 56
Display

Click on the first or last page to see other MX-B201D (serv.man6) service manuals if exist.