Sharp MX-B201D (serv.man6) Service Manual ▷ View online

MX-FX12  FAX SOFT SWITCH  2 - 12
S
W
41
1
Number of times 
of recall in busy
Used to set the number of times of recall when busy tone is 
detected during transmission.
2 times
0 Refer to User program 
“RECALL TIMES (BUSY)”.
When a value outside the 
set range is set, the initial 
value is set.
2
0
3
Setting is made in binary input.
0
4
When set to 0, recall is not made.
0
5
Set range
0
0 to 14times
(U.S.A.)
0 to 10 times
(U.K., Germany, France, Middle East)
0 to 9 times
(Singapore, Malaysia, India, Indonesia, Thailand, Vietnam)
0 to 3 times
(China, Hong Kong)
6
0
7
1
8
0
S
W
42
1
Direct send recall
(U.S.A., Canada)
Used to set whether direct send recall wait is allowed or not.
Allow
0
1: Inhibit
0: Allow
2
FAX receive auto 
select by CNG 
detection
Used to set whether FAX receive auto select is enabled or not when 
CNG signal is detected with external telephone used.
Allow
1
Refer to User program 
“FAX SIGNAL AUTO 
RECEIVE”.
1: Allow
0: Inhibit
3
Auto receive 
select in 
answering 
telephone 
connection mode
Used to set whether auto receive select function in answering 
telephone connection mode is enabled or not.
OFF
0
Refer to Main menu “AM 
MODE”.
1: ON
0: OFF
4
Inhibited to use
0
5
0
6
0
7
0
8
0
S
W
43
1
V.34 mode 
function
Used to set whether V.34 mode is enabled or not as a capacity of 
own machine in send/receive.
ON
1
1: ON
0: OFF
2
Inhibited to use
0
3
0
4
V.34  receive 
symbol speed 
mask
Used to set symbol speed mask in V.34 receive.
3429
1
When a value outside the 
set range is set, the initial 
value is set.
Bit No.
4
5
6
5
2400
0
0
0
0
2743
0
0
1
2800
0
1
0
6
3000
0
1
1
1
3200
1
0
0
3429
1
0
1
7
Inhibited to use
0
8
0
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12  FAX SOFT SWITCH  2 - 13
S
W
44
1
Sending speed
Used to set the speed of fax sending. 
* If SW43, B1 is off (V.34 mode is off)
  and if SW44, B1-4 is less than 6 (not V.34)
    ---> operate it at speed set in SW44, B1-4.
* If SW43, B1 is off (V.34 mode is off)
  and if SW44, B1-4 is over than 7 (V.34)
    ---> operate it at speed set in SW44, B1-4=5.
          V.17-14.4Kbps
* If SW43, B1 is on (V.34 mode is on)
  and if SW44, B1-4 is less than 6 (not V.34)
    ---> operate it at speed set in SW44, B1-4=V.34-33.6Kbps.
* If SW43, B1 is on (V.34 mode is on)
  and if SW44, B1-4 is over than 7 (V.34)
    ---> operate it at speed set in SW44, B1-4
33.6 K bps -> 
V.34
1
2
1
3
1
4
0
Bit No.
1
2
3
4
0: 2.4 K bps -> V.27ter
0
0
0
0
1: 2.4 K bps -> V.27ter
0
0
0
1
2: 4.8 K bps -> V.27
0
0
1
0
3: 7.2 K bps -> V.29
0
0
1
1
4: 9.6 K bps -> V.29
0
1
0
0
5: 12  K bps -> V.17
0
1
0
1
6: 14.4 K bps -> V.17
0
1
1
0
7: 16.8 K bps -> V.34
0
1
1
1
8: 19.2 K bps -> V.34
1
0
0
0
9: 21.6 K bps -> V.34
1
0
0
1
10: 24.6 K bps -> V.34
1
0
1
0
11: 26.4 K bps -> V.34
1
0
1
1
12: 28.8 K bps -> V.34
1
1
0
0
13: 31.2 K bps -> V.34
1
1
0
1
14: 33.6 K bps -> V.34
1
1
1
0
15: 33.6 K bps -> V.34
1
1
1
1
5
Reception speed
Used to set the speed of fax receiving.
* If SW43, B1 is off (V.34 mode is off)
  and if SW44, B5-8 is less than 6 (not V.34)
    ---> operate it at speed set in SW44, B5-8.
* If SW43, B1 is off (V.34 mode is off)
  and if SW44, B5-8 is over than 7 (V.34)
    ---> operate it at speed set in SW44, B5-8=5.
          V.17-14.4Kbps
* If SW43, B1 is on (V.34 mode is on)
  and if SW44,B5-8 is less than 6 (not V.34)
    ---> operate it at speed set in SW44, B5-8=V.34-33.6Kbps.
* If SW43, B1 is on (V.34 mode is on)
  and if SW44, B5-8 is over than 7 (V.34)
    ---> operate it at speed set in SW44, B5-8
33.6 K bps -> 
V.34
1
6
1
7
1
8
0
Bit No.
5
6
7
8
0: 2.4 K bps -> V.27ter
0
0
0
0
1: 2.4 K bps -> V.27ter
0
0
0
1
2: 4.8 K bps -> V.27
0
0
1
0
3: 7.2 K bps -> V.29
0
0
1
1
4: 9.6 K bps -> V.29
0
1
0
0
5: 12  K bps -> V.17
0
1
0
1
6: 14.4 K bps -> V.17
0
1
1
0
7: 16.8 K bps -> V.34
0
1
1
1
8: 19.2 K bps -> V.34
1
0
0
0
9: 21.6 K bps -> V.34
1
0
0
1
10: 24.6 K bps -> V.34
1
0
1
0
11: 26.4 K bps -> V.34
1
0
1
1
12: 28.8 K bps -> V.34
1
1
0
0
13: 31.2 K bps -> V.34
1
1
0
1
14: 33.6 K bps -> V.34
1
1
1
0
15: 33.6 K bps -> V.34
1
1
1
1
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12  FAX SOFT SWITCH  2 - 14
S
W
45
1
Inhibited to use
0
2
0
3
1
4
0
5
0
6
0
7
0
8
0
S
W
46
1
Inhibited to use
0
2
Specification of 
rotating direction 
duplex back 
surface print
Used to set whether the back surface is rotated 180 degrees in 
duplex print or not.
When set to 1, the back surface is rotated 180 degrees and printed.
When set to 0, the back surface is not rotated and printed.
180 degrees 
rotation
1
1: 180 degrees rotation
0: No 180 degrees rotation
3
Priority in the day 
of week
Used to set which is indicated first, day or day of week, when date 
format is in the sequence of day, month, and year.
When set to 1, day of week is indicated first, and then day is 
indicated.
When set to 0, day is indicated first, and then day of week is 
indicated.
No
0
1: Yes
0: No
4
Inhibited to use
0
5
Summer time
Used to set whether summer time function is enabled or not.
When set to 1, summer time function is enabled.
When set to 0, summer time function is disabled.
Inhibit
0
Refer to Entry Mode “DAY 
LIGHT SAVING”.
1: Allow
0: Inhibit
6
PBX setting 
(U.S.A., Canada, 
U.K., Netherlands, 
Luxembourg, 
Belgium, Australia, 
New Zealand: 
Inhibited to use)
Used to set Connect/Not Connect to PBX and to set the external 
line connection method when connected to PBX.
Setting OFF
0
Refer to User program 
“PBX SETTING MODE”.
When a value outside the 
set range is set, the initial 
value is set.
Bit No.
6
7
8
7
Setting OFF
0
0
0
0
Flash send
1
0
1
8
ID  send
1
1
0
0
S
W
47
1
Inhibited to use
0
2
External 
telephone 
connection
Used to set whether external telephone is used or not.
This switch must be set to YES in order to use external telephone.
Yes
1
1: Yes
0: No
3
Inhibited to use
0
4
0
5
0
6
0
7
0
8
0
S
W
48
1
Tone/Pulse default 
setup
Used to set the dial type.
TONE
1
Refer to User program 
“DIAL MODE”.
When a value outside the 
set range is set, the initial 
value is set.
Bit No.
1
2
2
10PPS
0
0
0
TONE
1
0
3
Telephone line 
menu
Used to set whether tone/pulse setting is displayed on the menu or 
not.
Allow
0
1: Inhibit
0: Allow
4
Inhibited to use
0
5
0
6
0
7
0
8
0
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12  FAX SOFT SWITCH  2 - 15
S
W
49
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
50
1
Line monitor 
volume
Used to set on-hook monitor volume and line volume in FAX 
communication.
Medium
1
When SPEAKER key is 
pressed, user setting can 
be made.
Bit No.
1
2
2
Silent
0
0
0
Small
0
1
Medium
1
0
Large
1
1
3
Inhibited to use
0
4
0
5
0
6
0
7
0
8
0
S
W
51
1
DTMF send level 
(High group) setup
Used to set high-group send level in DTMF signal send.
–6dBm
0 When a value outside the 
set range is set, the initial 
value is set.
2
Setting is made in binary input in the increment of 1.0dBm.
0
3
Binary input
1
4
Bit  No.
Set range
1
2
3
4
5
0 (0.0dBm) to 
21 (–21.0dBm)
1
5
0
6
CED detection 
time
Used to set detection time of CED/ANSam signal for judgment of 
detection.
1000ms
0
1: 500ms
0: 1000ms
7
Busy tone 
detection cycle
Used to set detection cycle of pulses of busy tone for detection of 
busy tone.
2puls
0
Bit No.
7
8
8
2puls
0
0
0
4puls
0
1
6puls
1
0
10puls
1
1
S
W
52
1
Busy tone 
detection level
Used to set the mini. Detection level in busy tone detection.
–43dB
0
Bit No.
1
2
–43dB
0
0
2
–35dB
0
1
0
–33dB
1
0
–30dB
1
1
3
Inhibited to use
0
4
Super G3 disabled 
in the last call-out 
of recall in case of 
an error
Used to set whether Super G3 is disabled or not in the last call-out 
of recall in case of a send error.
When, however, the number of recall in case of a send error is 0, 
this function does not operate.
Super G3 
disabled
0
1: Super G3 enabled
0: Super G3 disabled
5
Error process in 
RTN reception
Used to set whether RTN reception is judged as an error or not. 
(Only in G3 mode)
When set to 1, RTN reception is not judged as an error.
When set to 0, RTN reception is judged as an error.
Error
0
1: Not error
0: Error
6
DT detection level Used to set the detection level for Dial tone.
–43dB
0
–43dB
0
0
7
–35dB
0
1
0
–33dB
1
0
–30dB
1
1