DOWNLOAD Sharp MX-B201D (serv.man6) Service Manual ↓ Size: 1.19 MB | Pages: 56 in PDF or view online for FREE

Model
MX-B201D (serv.man6)
Pages
56
Size
1.19 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual MX-FX12
File
mx-b201d-sm6.pdf
Date

Sharp MX-B201D (serv.man6) Service Manual ▷ View online

MX-FX12  FAX SOFT SWITCH  2 - 16
S
W
52
8
V.34 control 
channel 
communication 
speed
Used to set control channel communication speed in V.34 mode.
If the remote machine does not make 2400bps enable, the speed is 
always 1200bps.
1200bps
0
1: 2400bps
0: 1200bps
S
W
53
1
Maximum DTMF 
send level
Used to set the max. send level of DTMF signal.
0dBm
0
2
Setting is made in binary input in the increment of 1.0dBm.
0
3
Binary input
0
Bit No.
Set range
1
2
3
4
0 (0.0dBm) to 
15 (–15.0dBm)
4
0
5
DTMF send level 
(difference 
between high and 
low level)
Used to set DTMF signal send level in low group by the difference 
from that in high group.
+2.0dBm
1
6
Setting is made in binary input in the increment of 0.5dBm.
0
Binary input
7
Bit  No.
Set range
5
6
7
8
0 (–2.0dBm) to 
15 (+5.5dBm)
0.5dBm unit
When set to 0: Low group = High 
group – (–2.0) dBm
0
8
0
S
W
54
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
55
1
CI signal OFF 
detection enable 
time
Used to set the min. OFF time for judgment of 1 pulse (1 call) of CI 
(call-in signal).
1200ms
1
2
1
3
If OFF time continues more than the set value, it is judged as 1 
pulse.
1
4
1
5
Setting is made in binary input in the increment of 10ms.
0
6
Binary input
0
7
Bit  No.
Set range
1
2
3
4
5
6
7
0 to 1270ms
0
8
Inhibited to use
0
S
W
56
1
CI signal ON 
detection enable 
time
Used to set the min. ON time for judgment of 1 pulse (1 call) of CI 
(call-in signal).
155ms
0
2
If ON time continues more than the set value, it is judged as 1 
pulse.
0
Setting is made in binary input in the increment of 10ms.
3
Binary input
0
Bit No.
Set range
1
2
3
0 (155ms) to 7 (225ms)
4
Inhibited to use
0
5
DT/BT detection 
frequency range
Used to set DT/BT detection frequency range.
245Hz–650Hz
1
Bit No.
5
6
Modem fixed (400Hz)
0
0
6
420Hz–680Hz
0
1
1
360Hz–440Hz
1
0
245Hz–650Hz
1
1
7
Inhibited to use
0
8
0
S
W
57
1
Inhibited to use
0
2
0
3
0
4
0
5
1
6
1
7
0
8
0
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12  FAX SOFT SWITCH  2 - 17
S
W
58
1
Dual wait inhibit 
time after CFR 
send
Used to set dual wait inhibit time after CFR send.
1600ms
1
2
Setting is made in binary input in the increment of 200ms.
0
3
Binary input
0
Bit No.
Set range
1
2
3
4
0 to 3000ms
4
0
5
FSK signal 
settlement time in 
double wait
Used to set FSK signal settlement time in double (dual) wait.
550ms
0
6
Setting is made in binary input in the increment of 50ms.
1
7
Binary input
1
Bit No.
Set range
5
6
7
8
Settlement time = 
50 (ms) x N + 200 (ms)
8
1
S
W
59
1
Inhibited to use
0
2
0
3
Reception SED 
ON level
Used to set reception SED ON level.
–48dB
1
Bit No.
3
4
–43dB
0
0
4
–38dB
0
1
1
–33dB
1
0
–48dB
1
1
5
Compromise 
Equalizer
Used to set transmission cable amplitude equalizer.
0dB
0
Bit No.
5
6
0dB
0
0
6
4dB
0
1
0
8dB
1
0
12dB
1
1
7
Reception cable 
amplitude 
equalizer
Used to set reception cable amplitude equalizer.
0dB
0
Bit No.
7
8
0dB
0
0
8
4dB
0
1
0
8dB
1
0
12dB
1
1
S
W
60
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
61
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
62
1
Inhibited to use
0
2
0
3
0
4
V.8 mode ANSam 
signal send time
Used to set ANSam/CED signal send time.
4sec.
0
Bit No.
4
5
3sec.
0
0
5
4sec.
0
1
1
5sec.
1
0
6sec.
1
1
6
Inhibited to use
0
7
0
8
0
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12  FAX SOFT SWITCH  2 - 18
S
W
63
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
64
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
65
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
66
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
67
1
Make time 
(10PPS) setup
Used to set make time in dialing in 10PPS.
40ms
1
2
Setting is made in binary input in the increment of 1ms.
1
3
Binary input
1
Bit No.
Set range
1
2
3
4
26 to 41ms
4
0
5
Make time 
(20PPS) setup
(China & Thailand 
only)
Used to set make time in dialing in 20PPS.
0
6
Setting is made in binary input in the increment of 1ms.
0
7
Binary input
0
Bit No.
Set range
5
6
7
8
9 to 24ms
8
0
S
W
68
1
Inhibited to use
0
2
0
3
0
4
0
5
T1 timer setup
Used to set time for connection of the line when the remote 
machine does not respond in FAX communication.
40sec.
0
6
0
7
The time of ITU-T standard is 35 ± 5sec.
1
Setting is made in binary input in the increment of 5sec.
8
Binary input
0
Bit No.
Set range
5
6
7
8
30 to 105sec.
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
MX-FX12  FAX SOFT SWITCH  2 - 19
S
W
69
1
Inhibited to use
0
2
0
3
0
4
0
5
T4 timer setup 
(Auto)
(Manual: +1.5sec.)
This sets the timer for up until reception of the response.
+1.5sec. at times of manual operation
3sec.
0
Bit No.
5
6
3sec.
0
0
6
4sec.
0
1
0
5sec.
1
0
6sec.
1
1
This is the timer for up until reception of the response to the DCS 
signal, etc.
3sec. ±15% under the ITU-T standard.
7
Inhibited to use
0
8
0
S
W
70
1
Inhibited to use
0
2
0
3
0
4
Reception waiting 
time between 
frames
Used to set reception wait time between frames.
3.4sec.
0
1: 4.4sec.
0: 3.4sec.
5
Preamble send 
time of 300bps
Used to set preamble send time of 300bps.
1.0sec.
0
Bit No.
5
6
0.5sec.
0
0
6
1.0sec.
0
1
1
1.5sec.
1
0
2.0sec.
1
1
7
RCP send times
Used to set number of times of RCP frame send.
3times
0
Bit No.
7
8
3 times
0
0
8
6  times
0
1
0
9 times
1
0
12 times
1
1
S
W
71
1
Waiting time to 
dial
This sets the waiting time from the end of line connection to the 
start of dial call at times of automatic dial calling.
3.5sec.
0
Bit No.
1
2
3.5sec.
0
0
2
4sec.
0
1
0
5sec.
1
0
6sec.
1
1
This only functions when dial tone detection is OFF.
3
Error rate of RTN 
sending
The threshold of the judgment whether to send RTN when 
reception of V17. 
60 line
1
As for the value of SW, the value of STD is indicated.
Other resolutions are as follows. 
  FINE = STD x 2
4
  SFINE = STD x 4
0
Bit No.
3
4
6line (STD)
0
0
12line (STD)
0
1
60line (STD)
1
0
120line (STD)
1
1
5
Interval DCS and 
TCF
Setting to determine how many seconds in the interval between 
DCS transmission and sending of the TCF signal.
75msec.
1
1: 75msec.
0: 150msec.
75±20ms in the ITU-T standard.
6
Checking time of 
TCF
The time that the received TCF signal checks is set while training.
1.0sec.
1
1: 1.0sec.
0: 1.3sec.
7
Inhibited to use
0
8
0
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
Page of 56