Sharp MX-6500N / MX-7500N (serv.man20) Service Manual ▷ View online

MX-7500N  SIMULATION  6 – 73
D
Process 
control 
Enable/
Disable 
setting
HUM_LIMIT
HUM judgment is made when 
turning ON the power and after 
passing TIME.
Color process 
control Enable
0 - 2
0
0
Process control 
Disable
1
BK process 
control Enable
2
E
HUM
The temperature and humidity in the 
machine are monitored in every 2 
hours only during a job, and the 
change in the temperature/humidity 
is above the specified level 
compared with that in execution of 
the previous process control.
Color process 
control Enable
0 - 2
0
0
Process control 
Disable
1
BK process 
control Enable
2
F
REV1
YES
When a certain level of the 
accumulated traveling distance of 
BK or M position OPC drum unit is 
reached after the power is supplied.
Allow
0 - 1
0
0
NO
Inhibit
1
G
REV2_BK
YES
When a certain level of the 
accumulated traveling distance of 
BK position OPC drum unit is 
reached after execution of the 
previous density correction.
Allow
0 - 1
0
0
NO
Inhibit
1
H
REV2_CL
YES
When a certain level of the 
accumulated traveling distance of M 
position OPC drum unit is reached 
after execution of the previous 
density correction.
Allow
0 - 1
0
0
NO
Inhibit
1
I
REFRESH MODE
YES
YES/NO setting of the display of the 
manual process control key by key 
operations
Key operation 
display YES
0 - 1
0
1
NO
Key operation 
display NO
1
J
Process 
control 
execution 
condition 
setting
DAY
After color job after passing a certain 
days from execution of the previous 
color process control. When next 
warming up if there is no color job.
0: Disable of the 
specified days 
judgment
0 - 999
0
1
1 - 999: 1 - 999 
days passing
999
K
HI-COV
The average print ratio is monitored 
in a certain interval, and the high 
print process control execution is 
judged.
Process control 
interval setting 
for every 10 
pages
0 - 2
0
0
High print 
judgment 
disable
1
Judgment at the 
30th paper 
(continuous).
2
L
LO-COV
Low print document continuous 
printing process control execution 
judgment
Allow
0 - 1
0
0
Inhibit
1
M
TonerCA-END
When the toner cartridge remaining 
quantity reached 25% or below, the 
process control interval is changed. 
Allow
0 - 1
0
1
Inhibit
1
N
JOB STOP
Enable/Disable setting of execution 
[REV2_BK], [REV2_CL], [HI-COV], 
and [LO-COV] judgment during a 
job.
Allow
0 - 1
0
1
Inhibit
1
O
AVERAGE-PAGE
Average print ratio paper number 
setting
1: 10 pages - 
5: 50 pages
1 - 5
1
3
Corresponds to 
1 step/
10 pages.
5
P
LIMIT PAGE
Setting of the job connection number 
of sheets/limitation of the number of 
sheets
1: 10 pages - 
10: 100 pages
1 - 99
1
10
Corresponds to 
1 step/
10 pages.
10
Q
PIX_RATIO_BK
Magnification ratio setting (%) of the BK toner count 
specified value
1 - 999
10
When 100 is entered, it corresponds to 1kp at 5% print.
R
PIX_RATIO_CL
Magnification ratio setting (%) of the color (CMY) toner 
count specified value
1 - 999
10
When 100 is entered, it corresponds to 1kp at 5% print.
S
INTERVAL TIME
Setting of the leaving time when turning ON the power 
(including the sleep recovery time) (h: hour)
1 - 255
3
(1 - 255; 1 - 255h passed)
Item/Category
Display
Content
Setting range
Default 
value
MX-7500N  SIMULATION  6 – 74
T
Process 
control 
execution 
condition 
setting
HUM HOUR
[HUM] temperature/humidity monitoring time
Interval setting (10 minutes unit)
1 - 24
2
U
HUM_DIF
Area difference specified value when compared with the 
execution of the previous process control of "HUM"
1 - 9
2
V
BK_RATIO
[REV2_BK] BK position OPC drum traveling distance 
value magnification ratio setting (%)
1 - 999
(Entry of 20 corresponds to 
10,000mm.)
15
W
M_RATIO
[REV2_CL] M position OPC drum traveling distance 
value magnification ratio setting (%)
1 - 999
(Entry of 20 corresponds to 
10,000mm.)
15
X
REV1_RATIO
[REV1_BK] BK position OPC drum traveling distance 
value magnification ratio setting (%)
1 - 255
20
(Entry of 100 corresponds to 
70,000mm.)
Y
LOW_RATIO
LOW mode process control execution interval
1 - 999
15
COLOR BORDER
Setting of the 
magnification ratio of the 
upper limit of the M 
position OPC drum 
traveling distance when 
BK process control is 
executed.
0: BK process control is 
executed without ratio 
judgment of the M OPC 
drum traveling distance.
0 - 999
20
1 - 999;1 - 999(%)
AA 
BK ONLY
Enable/Disable setting of 
the BK process control 
execution when 
monochrome printing is 
continued, and setting of 
the number of repetitions.
Enable 5 times
0 - 6
0
5
Enable 1 - 5 times
1 - 5
Inhibit
6
AB 
P2P PV_CL
Interval of number of sheets of color patch making of 
process control between papers
0 - 255
60
AC 
P2P PV_BK
Interval of number of sheets of BK patch making of 
process control between papers
0 - 255
60
AD 
HT_DIF
Used to judge the execution of HT process control.
1 - 255
40
Bias variation difference value
AE  Registration 
adjustment 
setting
RG_ON_SYNC
CL
Power ON process control Synchronization / not 
synchronization switch
0 - 2
0
0
ALL
1
CL/BK
2
AF 
RG_TEMP_TIMER
Setting of execution timing after turning ON the power
0 - 240
0
(MINUTE)
AG 
RG_PERM_TIMER
Setting of the span from execution disable to enable
0 - 15
1
(HOUR)
AH 
RG_HOUR_TIMER
Setting of the span of timer execution
0 - 15
5
(Above) + (HOUR)
AI 
RG_BW_SYNC
Enable/Disable setting of the registration 
adjustment in a monochrome job. 
Allow
0 - 1
0
1
Inhibit
1
AJ  MC cleaner 
control
MC_CLEAN_TIME 
MC automatic cleaning 
execution interval
0: Not executed
0, 5 - 99
0
3
5 - 99: Executed
5 - 99
AK 
MC_CLEAN_DURING_JOB 
MC automatic cleaning 
execution setting during 
JOB
ON
0 - 1
0
0
OFF
1
AL 
MC_DISCHARGE_TIME_1 
MC discharge setting after 
MC automatic cleaning
0: Not executed
0 - 999
0
0
1- 999: Executed by value
1 - 999
AM
MC_DISCHARGE_TIME_2 
MC automatic cleaning 
execution interval
0: Not executed
0 - 999
0
0
1- 999: Executed by value
1 - 999
AN
MC_DISCHARGE_TIME_3 
MC automatic cleaning 
execution interval
0: Not executed
0 - 999
0
0
1- 999: Executed by value
1 - 999
AO  PTC cleaner 
control
PTC_CLEAN_TIME_CL 
PTC automatic cleaning interval (Color)
0 - 300
50
AP
PTC_CLEAN_TIME_BK 
PTC automatic cleaning interval (Monochrome)
0 - 300
100
AQ Drum reverse 
rotation 
control
DRUM_REVERSE
Drum reverse rotation 
control setting
Enable
0 - 1
0
1
Disable
1
AR Judgment of 
execution of 
the 
registration 
adjustment 
between 
sheets
PAR_CNT SYNC
Judgment of execution of the registration adjustment 
between sheets, interval of number of sheets
1 - 999 (sheet)
AS
PAR_TIMER SYNC
Judgment of execution of the registration adjustment 
between sheets, interval of time
0 - 240 (minute)
AT
PAR_TEMP SYNC
Judgment of execution of the registration adjustment 
between sheets, difference in temperature
0 - 99 degrees C
AU  2nd transfer 
belt skew 
correction  
control
2TBMD 
2nd transfer belt skew 
correction control Enable / 
Disable
Enable
0 - 1
0
0
Disable
1
Item/Category
Display
Content
Setting range
Default 
value
MX-7500N  SIMULATION  6 – 75
 
44-29
Purpose
Setting
Function (Purpose)
Used to set the operating conditions of the
process control during a job.
Section
Process
Operation/Procedure
1) Select  a  target  item  of  setting  with  scroll  key  on  the  touch
panel.
2) Enter the set value with 10-key.
3) Press [OK] key.
HV: High density process control
HT: Halftone process control
 
44-31
Purpose
Adjustment/Setup
Function (Purpose)
Used  to  check  the  deflection  of  the  OPC
drum.
Section
Process
Operation/Procedure
NOTE: For the OPC drum phase adjustment, do not use this simu-
lation, but use SIM50-22 (auto adjustment).
NOTE: This  Simulation  is  for  the  MFP  development,  not  for  ser-
vice.
1) Select item A with scroll key.
2) Enter the value corresponding to the adjustment pattern with
10-key.
3) Press [EXECUTE] key. (The adjustment pattern is printed out.)
4) Select  an  adjustment  pattern  whose  deflection  is  within  two
scale lines on the adjustment pattern of C,M, Y colors.
5) Select item B with scroll key.
6) Enter the adjustment pattern sheet number selected in proce-
dure 4).
7) Press [EXECUTE] key.
8) The adjusted adjustment pattern is printed.
 
44-37
Purpose
Adjustment/Setup
Function (Purpose)
Used  to  set  the  development  bias  correc-
tion level in the continuous printing opera-
tion.
Section
Operation/Procedure
1) Select a set target color with the touch panel.
2) Select a target item with scroll keys.
3) Enter the set value with 10-key.
4) Press [OK] key. (The set value is saved.)
NOTE: When the print density is varied in the continuous printing
operation, this simulation is used.
Item/Display
Content
Setting range
Default 
value
A
COPY
During copy 
job
0 - 
2
0: No execution
1: HV only
2: HV - HT
2
B
PRINTER During print 
job
2
C FAX
During FAX 
print job
2
D SELF 
PRINT
During self 
print
2
E
CPY TO 
PRT 
TABLE
Halftone 
process 
control 
copier - 
printer 
conversion 
table select
0 - 
1
0: CALCULATED
(Color balance 
calculation value 
(Revised every time 
when SIM46-74 is 
executed.))
1: DEFAULT
(Default (Fixed value))
0
Button
Item
Display
Content
Setting range
Default value
K
A
GB_ADJ_CL_K_M_DATA_1
Grid bias correction data 1 in color printing (middle speed)
0 - 5
0
B
GB_ADJ_CL_K_M_DATA_2
Grid bias correction data 2 in color printing (middle speed)
0 - 5
0
C
GB_ADJ_CL_K_M_DATA_3
Grid bias correction data 3 in color printing (middle speed)
0 - 5
0
D
GB_ADJ_CL_K_L_DATA_1
Grid bias correction data 1 in color printing (low speed 1)
0 - 5
0
E
GB_ADJ_CL_K_L_DATA_2
Grid bias correction data 2 in color printing (low speed 1)
0 - 5
0
F
GB_ADJ_CL_K_L_DATA_3
Grid bias correction data 3 in color printing (low speed 1)
0 - 5
0
G
GB_ADJ_CL_K_L2_DATA_1
Grid bias correction data 1 in color printing (low speed 2)
0 - 5
0
H
GB_ADJ_CL_K_L2_DATA_2
Grid bias correction data 2 in color printing (low speed 2)
0 - 5
0
I
GB_ADJ_CL_K_L2_DATA_3
Grid bias correction data 3 in color printing (low speed 2)
0 - 5
0
MX-7500N  SIMULATION  6 – 76
<Use example>
Make multi copy of 10 sheets. If the density of 10th sheet is greater than that of the first sheet, decrease the set value.
Make multi copy of 10 sheets. If the density of 10th sheet is smaller than that of the first sheet, increase the set value.
When the set value is 0 (Default), the correction level does not work.
 
44-43
Purpose
Data display
Function (Purpose)
Used  to  display  the  identification  informa-
tion of the developing unit.
Section
Developing system
Operation/Procedure
The identification number and the identification signal level of the
developing unit are displayed.
* The developing unit is identified by the combination of items E, F,
G, H and items I, J, K, and L.
C
A
GB_ADJ_CL_C_M_DATA_1
Grid bias correction data 1 in color printing (middle speed)
0 - 5
0
B
GB_ADJ_CL_C_M_DATA_2
Grid bias correction data 2 in color printing (middle speed)
0 - 5
0
C
GB_ADJ_CL_C_M_DATA_3
Grid bias correction data 3 in color printing (middle speed)
0 - 5
0
D
GB_ADJ_CL_C_L_DATA_1
Grid bias correction data 1 in color printing (low speed 1)
0 - 5
0
E
GB_ADJ_CL_C_L_DATA_2
Grid bias correction data 2 in color printing (low speed 1)
0 - 5
0
F
GB_ADJ_CL_C_L_DATA_3
Grid bias correction data 3 in color printing (low speed 1)
0 - 5
0
G
GB_ADJ_CL_C_L2_DATA_1
Grid bias correction data 1 in color printing (low speed 2)
0 - 5
0
H
GB_ADJ_CL_C_L2_DATA_2
Grid bias correction data 2 in color printing (low speed 2)
0 - 5
0
I
GB_ADJ_CL_C_L2_DATA_3
Grid bias correction data 3 in color printing (low speed 2)
0 - 5
0
M
A
GB_ADJ_CL_M_M_DATA_1
Grid bias correction data 1 in color printing (middle speed)
0 - 5
0
B
GB_ADJ_CL_M_M_DATA_2
Grid bias correction data 2 in color printing (middle speed)
0 - 5
0
C
GB_ADJ_CL_M_M_DATA_3
Grid bias correction data 3 in color printing (middle speed)
0 - 5
0
D
GB_ADJ_CL_M_L_DATA_1
Grid bias correction data 1 in color printing (low speed 1)
0 - 5
0
E
GB_ADJ_CL_M_L_DATA_2
Grid bias correction data 2 in color printing (low speed 1)
0 - 5
0
F
GB_ADJ_CL_M_L_DATA_3
Grid bias correction data 3 in color printing (low speed 1)
0 - 5
0
G
GB_ADJ_CL_M_L2_DATA_1
Grid bias correction data 1 in color printing (low speed 2)
0 - 5
0
H
GB_ADJ_CL_M_L2_DATA_2
Grid bias correction data 2 in color printing (low speed 2)
0 - 5
0
I
GB_ADJ_CL_M_L2_DATA_3
Grid bias correction data 3 in color printing (low speed 2)
0 - 5
0
Y
A
GB_ADJ_CL_Y_M_DATA_1
Grid bias correction data 1 in color printing (middle speed)
0 - 5
0
B
GB_ADJ_CL_Y_M_DATA_2
Grid bias correction data 2 in color printing (middle speed)
0 - 5
0
C
GB_ADJ_CL_Y_M_DATA_3
Grid bias correction data 3 in color printing (middle speed)
0 - 5
0
D
GB_ADJ_CL_Y_L_DATA_1
Grid bias correction data 1 in color printing (low speed 1)
0 - 5
0
E
GB_ADJ_CL_Y_L_DATA_2
Grid bias correction data 2 in color printing (low speed 1)
0 - 5
0
F
GB_ADJ_CL_Y_L_DATA_3
Grid bias correction data 3 in color printing (low speed 1)
0 - 5
0
G
GB_ADJ_CL_Y_L2_DATA_1
Grid bias correction data 1 in color printing (low speed 2)
0 - 5
0
H
GB_ADJ_CL_Y_L2_DATA_2
Grid bias correction data 2 in color printing (low speed 2)
0 - 5
0
I
GB_ADJ_CL_Y_L2_DATA_3
Grid bias correction data 3 in color printing (low speed 2)
0 - 5
0
Button
Item
Display
Content
Setting range
Default value
Item/Display
Content
Display 
range
NOTE
A DVCH 
KIND K
K developing unit 
identification number
1 - 9
The model 
identification number 
of the developing unit 
which is backed up in 
the EEPROM of the 
machine.
B DVCH 
KIND C
C developing unit 
identification number
1 - 9
C DVCH 
KIND M
M developing unit 
identification number
1 - 9
D DVCH 
KIND Y
Y developing unit 
identification number
1 - 9
E DV_TYP_
SEL_K
K developing unit 
identification 
detection
0 - 1
0 = High (Open)
1 = Low (GND)
F
DV_TYP_
SEL_C
C developing unit 
identification 
detection
0 - 1
G DV_TYP_
SEL_M
M developing unit 
identification 
detection
0 - 1
H DV_TYP_
SEL_Y
Y developing unit 
identification 
detection
0 - 1
I
DVCH_A
D_K
K developing unit 
identification AD 
value
0 - 255
AD value of the 
developing unit 
identification voltage
J
DVCH_A
D_C
C developing unit 
identification AD 
value
0 - 255
K
DVCH_A
D_M
M developing unit 
identification AD 
value
0 - 255
L
DVCH_A
D_Y
Y developing unit 
identification AD 
value
0 - 255
Item/Display
Content
Display 
range
NOTE
Page of 127