DOWNLOAD Sharp MX-6201N / MX-7001N (serv.man19) Service Manual ↓ Size: 4.25 MB | Pages: 127 in PDF or view online for FREE

Model
MX-6201N MX-7001N (serv.man19)
Pages
127
Size
4.25 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / SIMULATIONS SECTION
File
mx-6201n-mx-7001n-sm19.pdf
Date

Sharp MX-6201N / MX-7001N (serv.man19) Service Manual ▷ View online

MX-7001N  SIMULATION  7 – 49
H
HL_EX PLAIN 
BW HH
Correction value for 
black and white plain 
paper external 
thermistor set value 
under HH environment
50
50
I
HL_UM PLAIN 
CL HH
Correction value for 
color plain paper upper 
thermistor main set 
value under HH 
environment
45
45
J
HL_LM PLAIN 
CL HH
Correction value for HH 
environment color plain 
paper lower thermistor 
main set value
50
50
K
HL_US PLAIN 
CL HH
Correction value for 
color plain paper upper 
thermistor sub set value 
under HH environment
45
45
L
HL_EX PLAIN CL 
HH
Correction value for 
color plain paper 
external thermistor set 
value under HH 
environment
50
50
M
WARMUP 
FUMON HL_UM 
T HH
Correction value for 
fusing motor previous 
rotation start external 
thermistor set value 
under HH environment
50
50
N
WARMUP 
FUMOFF HL_EX 
TEMP HH
Correction value for HH 
environment fusing 
motor front rotation 
continuation time
50
50
O
WARMUP END 
TIME HH
Correction value for 
warm-up completion 
time under HH 
environment
50
50
P
HL_UM HEAVY1 
BW HH
Correction value for HH 
environment black and 
white heavy paper 1 
upper thermistor main 
set value
50
50
Q
HL_LM HEAVY1 
BW HH
Correction value for HH 
environment black and 
white heavy paper 1 
lower thermistor main 
set value
50
50
R
HL_US HEAVY1 
BW HH
Correction value for HH 
environment black and 
white heavy paper 1 
upper thermistor sub 
set value
50
50
S
HL_EX HEAVY1 
BW HH
Correction value for HH 
environment black and 
white heavy paper 1 
external thermistor set 
value
50
50
T
HL UM HEAVY1 
CL HH
Correction value for HH 
environment heavy 
paper 1 upper 
thermistor main set 
value
50
50
U
HL LM HEAVY1 
CL HH
Correction value for HH 
environment color 
heavy paper 1 lower 
thermistor main set 
value
50
50
V
HL US HEAVY1 
CL HH
Correction value for HH 
environment heavy 
paper 1 upper 
thermistor sub set value
50
50
W
HL EX HEAVY1 
CL HH
Correction value for HH 
environment color 
heavy paper 1 external 
thermistor set value
50
50
Item
Default value
62-sheet 
machine
70-sheet 
machine
X
HL UM HEAVY2 
BW HH
Correction value for HH 
environment black and 
white heavy paper 2 
upper thermistor main 
set value
50
50
Y
HL LM HEAVY2 
BW HH
Correction value for HH 
environment black and 
white heavy paper 2 
lower thermistor main 
set value
50
50
Z
HL US HEAVY2 
BW HH
Correction value for HH 
environment black and 
white heavy paper 2 
upper thermistor sub 
set value
50
50
AA
HL EX HEAVY2 
BW HH
Correction value for HH 
environment black and 
white heavy paper 2 
external thermistor set 
value
50
50
AB
HL UM HEAVY2 
CL HH
Correction value for HH 
environment heavy 
paper 2 upper 
thermistor main set 
value
50
50
AC
HL LM HEAVY2 
CL HH
Correction value for HH 
environment color 
heavy paper 2 lower 
thermistor main set 
value
50
50
AD
HL US HEAVY2 
CL HH
Correction value for HH 
environment heavy 
paper 2 upper 
thermistor sub set value
50
50
AE
HL EX HEAVY2 
CL HH
Correction value for HH 
environment color 
heavy paper 2 external 
thermistor set value
50
50
AF
HL_UM OHP HH
Correction value for 
OHP upper thermistor 
main set value under 
HH environment
50
50
AG
HL_LM OHP HH
Correction value for HH 
environment OHP lower 
thermistor mains et 
value
50
50
AH
HL_US OHP HH
Correction value for 
OHP upper thermistor 
sub set value under HH 
environment
50
50
AI
HL_EX OHP HH
Correction value for 
OHP external 
thermistor set value 
under HH environment
50
50
AJ
HL_UM 
ENVELOPE HH
Correction value for 
enveloper upper 
thermistor main set 
value under HH 
environment
50
50
AK
HL_LM 
ENVELOPE HH
Correction value for HH 
environment envelope 
lower thermistor main 
set value
50
50
AL
HL_US 
ENVELOPE HH
Correction value for 
enveloper upper 
thermistor sub set value 
under HH environment
50
50
AM
HL_EX 
ENVELOPE HH
Correction value for 
envelope external 
thermistor set value 
under HH environment
50
50
Item
Default value
62-sheet 
machine
70-sheet 
machine
MX-7001N  SIMULATION  7 – 50
 
43-22
Purpose
Adjustment/Setting
Function (Purpose) Used to set the environment correction
under low temperature and low humidity (L/
L) for the fusing temperature setting (SIM
43-4) in each paper mode.
Section
Operation/Procedure
1)
Select an item to be set with [
↑] and [↓] keys.
2)
Enter the adjustment value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved. 
Correction value: -49 to +49, 1 count = 1
°C change
AN
HL_UM E-STAR 
HH
Correction value for 
upper thermistor main 
set value when 
preheating under HH 
environment
50
50
AO
HL US E-STAR 
HH
Correction value for HH 
environment preheating 
upper thermistor sub 
set value
50
50
AP
HL EX E-STAR 
HH
Correction value for HH 
environment preheating 
external thermistor set 
value
50
50
AQ
HL_UM PRE-
JOB HH 
Correction value for 
upper thermistor main 
set value when 
recovering from 
preheating under HH 
environment
50
50
AR
HL UM THIN 
PAPER BW HH
Correction value for HH 
environment black and 
white thin paper upper 
thermistor main set 
value
45
45
AS
HL LM THIN 
PAPER BW HH
Correction value for HH 
environment black and 
white thin paper lower 
thermistor main set 
value
45
45
AT
HL US THIN 
PAPER BW HH
Correction value for HH 
environment black and 
white thin paper upper 
thermistor sub set value
45
45
AU
HL EX THIN 
PAPER BW HH
Correction value for HH 
environment black and 
white thin paper 
external thermistor set 
value
45
45
AV
HL UM THIN 
PAPER CL HH
Correction value for HH 
environment color thin 
paper upper thermistor 
main set value
45
45
AW
HL LM THIN 
PAPER CL HH
Correction value for HH 
environment color thin 
paper lower thermistor 
main set value 
45
45
AX
HL US THIN 
PAPER CL HH
Correction value for HH 
environment color thin 
paper upper thermistor 
sub set value
45
45
AY
HL EX THIN 
PAPER CL HH
Correction value for HH 
environment color thin 
paper external 
thermistor set value 
45
45
AZ
HL UM THIN 
PAPER READY 
HH
Correction value for HH 
environment thin paper 
ready upper thermistor 
main temperature value
45
45
BA
HL UM REC 
PAPER BW HH
Correction value for HH 
environment black and 
white recycled paper 
upper thermistor main 
set value
45
45
BB
HL LM REC 
PAPER BW HH
Correction value for HH 
environment black and 
white recycled paper 
lower thermistor main 
set value
45
45
BC
HL US REC 
PAPER BW HH
Correction value for HH 
environment black and 
white recycled paper 
upper thermistor sub 
set value
45
45
Item
Default value
62-sheet 
machine
70-sheet 
machine
BD
HL EX REC 
PAPER BW HH
Correction value for HH 
environment black and 
white recycled paper 
external thermistor set 
value
45
45
BE
HL UM REC 
PAPER CL HH
Correction value for HH 
environment color 
recycled paper upper 
thermistor main set 
value
45
45
BF
HL LM REC 
PAPER CL HH
Correction value for HH 
environment color 
recycled paper lower 
thermistor main set 
value
45
45
BG
HL US REC 
PAPER CL HH
Correction value for HH 
environment color 
recycled paper upper 
thermistor sub set value
45
45
BH
HL EX REC 
PAPER CL HH
Correction value for HH 
environment color 
recycled paper external 
thermistor set value
45
45
BI
HL UM REC 
PAPER READY 
HH
Correction value for HH 
environment recycled 
paper ready upper 
thermistor main 
temperature value
45
45
Item
Default 
value
A
HL_UM PLAIN 
BW DUP LL
Correction value for black and white 
plain paper duplex upper thermistor 
main set value under LL environment
50
B
HL_LM PLAIN 
BW DUP LL
Correction value for LL environment 
black and white plain paper duplex 
lower thermistor main set value
50
Item
Default value
62-sheet 
machine
70-sheet 
machine
A㧦 40
HL_UM READY  HH
B㧦 50
HL_LM READY HH
C㧦40
HL_US READY  HH
D㧦45
HL_EX READY HH
A:
SIMULATION NO.43㧙21
FUSER TEMP ADJUSTMENT (HH)
40
1 㨪 99㨉
OK
TEST
CLOSE
E㧦40
HL_UM PLAIN BW HH
F㧦50
HL_LM PLAIN BW HH
G㧦40
HL_US PLAIN BW HH
H㧦50
HL_EX PLAIN BW HH
I㧦 40
HL_UM PLAIN CL HH
J㧦 50
HL_LM PLAIN CL HH
K㧦40
HL_US PLAIN CL HH
L㧦 50
HL_EX PLAIN CL HH
MX-7001N  SIMULATION  7 – 51
 
43-23
Purpose
Adjustment/Setting
Function (Purpose) Used to set the environment correction
under high temperature and high humidity
(H/H) for the fusing temperature setting
(SIM 43-4) in each paper mode.
Section
Operation/Procedure
1)
Select an item to be set with [
↑] and [↓] keys.
2)
Enter the adjustment value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved. 
Correction value: -49 to +49, 1 count = 1
°C change
C
HL_US PLAIN 
BW DUP LL
Correction value for black and white 
plain paper duplex upper thermistor 
sub set value under LL environment
50
D
HL_EX PLAIN 
BW DUP LL
Correction value for black and white 
plain paper duplex external thermistor 
set value under LL environment
50
E
PLAIN BW DUP 
APP CNT LL
Correction value for black and white 
plain paper duplex applicable number 
of sheets under LL environment
50
F
HL_UM PLAIN 
CL DUP LL
Correction value for color plain paper 
duplex upper thermistor main set value 
under LL environment
50
G
HL_LM PLAIN 
CL DUP LL
Correction value for LL environment 
color plain paper duplex lower 
thermistor main set value
50
H
HL_US PLAIN 
CL DUP LL
Correction value for color plain paper 
duplex upper thermistor sub set value 
under LL environment
50
I
HL_EX PLAIN 
CL DUP LL
Correction value for color plain paper 
duplex external thermistor set value 
under LL environment
55
J
PLAIN CL DUP 
APP CNT LL
Correction value for color plain paper 
duplex applicable number of sheets 
under LL environment
50
K
HL_UM HEAVY 
BW DUP LL
Correction value for black and white 
heavy paper duplex upper thermistor 
main set value under LL environment
50
L
HL_LM HEAVY 
BW DUP LL
Correction value for LL environment 
black and white duplex lower thermistor 
main set value
50
M
HL_US HEAVY 
BW DUP LL
Correction value for black and white 
heavy paper duplex upper thermistor 
sub set value under LL environment
50
N
HL_EX HEAVY 
BW DUP LL
Correction value for black and white 
heavy paper duplex external thermistor 
set value under LL environment
50
O
HEAVY BW 
DUP APP CNT 
LL
Correction value for black and white 
heavy paper duplex applicable number 
of sheets under LL environment
50
P
HL_UM HEAVY 
CL DUP LL
Correction value for color heavy paper 
duplex upper thermistor main set value 
under LL environment
50
Q
HL_LM HEAVY 
CL DUP LL
Correction value for LL environment 
black and white heavy paper duplex 
lower thermistor main set value
50
R
HL_US HEAVY 
CL DUP LL
Correction value for color heavy paper 
duplex upper thermistor sub set value 
under LL environment
50
S
HL_EX HEAVY 
CL DUP LL 
Correction value for color heavy paper 
duplex external thermistor set value 
under LL environment
50
T
HEAVY CL DUP 
APP CNT LL
Correction value for color heavy paper 
duplex applicable number of sheets 
under LL environment
50
Item
Default 
value
A : 60
;
HL_UM PLAIN BW DUP LL
B : 60
;
HL_LM PLAIN BW DUP LL
C : 60
;
HL_US PLAIN BW DUP LL
D : 50
;
HL_EX PLAIN BW DUP LL
A:
SIMULATION NO.43-22
FUSER TEMP ADJUSTMENT (LL:DUP)
60
1
99
OK
TEST
CLOSE
E : 50
;
PLAIN BW DUP APP CNT LL
F : 55
;
HL_UM PLAIN CL DUP LL
G : 55
;
HL_LM PLAIN CL DUP LL
H : 55
;
HL_US PLAIN CL DUP LL
I : 55
;
HL_EX PLAIN CL DUP LL
J : 50
;
PLAIN CL DUP APP CNT LL
K : 60
;
HL_UM HEAVY BW DUP LL
L : 60
;
HL_LM HEAVY BW DUP LL
Item
Default value
62 sheet 
machine
70 sheet 
machine
A
HL_UM 
PLAIN BW 
DUP HH
Correction value for black and 
white upper thermistor main 
set value under HH 
environment
50
40
B
HL_LM 
PLAIN BW 
DUP HH
Correction value for HH 
environment black and white 
plain paper duplex lower 
thermistor main set value
50
50
C
HL_US 
PLAIN BW 
DUP HH
Correction value for black and 
white upper thermistor sub set 
value under HH environment
50
45
D
HL_EX 
PLAIN BW 
DUP HH
Correction value for black and 
white plain paper duplex 
external thermistor set value 
under HH environment
50
50
E
PLAIN  BW 
DUP APP 
CNT HH
Correction value for black and 
white plain paper duplex 
applicable number of sheets 
under HH environment
50
50
F
HL_UM 
PLAIN CL 
DUP HH
Correction value for color plain 
paper duplex upper thermistor 
main set value under HH 
environment
50
50
G
HL_LM 
PLAIN CL 
DUP HH
Correction value for HH 
environment color plain paper 
duplex lower thermistor main 
set value
50
50
H
HL_US 
PLAIN CL 
DUP HH
Correction value for color plain 
paper duplex upper thermistor 
sub set value under HH 
environment
50
50
I
HL_EX 
PLAIN CL 
DUP HH
Correction value for color plain 
paper duplex external 
thermistor set value under HH 
environment
50
50
J
PLAIN  CL 
DUP APP 
CNT HH
Correction value for color plain 
paper duplex applicable 
number of sheets under HH 
environment
50
50
K
HL_UM 
HEAVY BW 
DUP HH
Correction value for black and 
white heavy paper duplex 
upper thermistor main set 
value under HH environment
50
50
L
HL_LM 
HEAVY BW 
DUP HH
Correction value for HH 
environment black and white 
duplex lower thermistor main 
set value
50
50
M
HL_US 
HEAVY BW 
DUP HH
Correction value for black and 
white heavy paper duplex 
upper thermistor sub set value 
under HH environment
50
50
N
HL_EX 
HEAVY BW 
DUP HH
Correction value for black and 
white heavy paper duplex 
external thermistor set value 
under HH environment
50
50
MX-7001N  SIMULATION  7 – 52
 
43-24
Purpose
Adjustment/Setting
Function (Purpose) Used to set the correction of the tempera-
ture adjustment value of SIM 43-1 and 43-
4. 
Section
Operation/Procedure
1)
Select an item to be set with [
↑] and [↓] keys.
2)
Enter the adjustment value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved. 
Correction value: -49 to +49, 1 count = 1
°C change
O
HEAVY BW 
DUP APP 
CNT HH
Correction value for black and 
white heavy paper duplex 
applicable number of sheets 
under HH environment
50
50
P
HL_UM 
HEAVY CL 
DUP HH
Correction value for color 
heavy paper duplex upper 
thermistor main set value 
under HH environment
50
50
Q
HL_LM 
HEAVY CL 
DUP HH
Correction value for HH 
environment black and white 
heavy paper duplex lower 
thermistor main set value
50
50
R
HL_US 
HEAVY CL 
DUP HH
Correction value for color 
heavy paper duplex upper 
thermistor sub set value under 
HH environment
50
50
S
HL_EX 
HEAVY CL 
DUP HH 
Correction value for color 
heavy paper duplex external 
thermistor set value under HH 
environment
50
50
T
HEAVY CL 
DUP APP 
CNT HH
Correction value for color 
heavy paper duplex applicable 
number of sheets under HH 
environment
50
50
Item
Default value
62 sheet 
machine
70 sheet 
machine
A㧦 50
HL_UM PLAIN BW DUP HH
B㧦 50
HL_LM PLAIN BW DUP HH
C㧦50
HL_US PLAIN BW DUP HH
D㧦50
HL_EX PLAIN BW DUP HH
A:
SIMULATION NO.43-23
FUSER TEMP ADJUSTMENT (HH:DUP)
50
1 㨪 99㨉
OK
TEST
CLOSE
E㧦50
PLAIN BW DUP APP CNT HH
F㧦50
HL_UM PLAIN CL DUP HH
G㧦50
HL_LM PLAIN CL DUP HH
H㧦50
HL_US PLAIN CL DUP HH
I㧦 50
HL_EX PLAIN CL DUP HH
J㧦 50
PLAIN CL DUP APP CNT HH
K㧦50
HL_UM HEAVY BW DUP HH
L㧦 50
HL_LM HEAVY BW DUP HH
Item
Default value
100V series
200V series
62-sheet 
machine
70-sheet 
machine
62-sheet 
machine
70-sheet 
machine
A
NN_120_ 
WUP_HL_UM&HL_US
Warm-up completion 
temperature correction 
value
When power 
booting at lower 
than 120
°C under 
NN environment
Upper heater lamp main/
sub
55
50
55
50
B
NN_120_ WUP_HL_LM
Lower heater lamp main 
50
45
50
45
C
NN_120_WUP_HL_EX
External heater lamp main
50
50
50
50
D
LL_120_ 
WUP_HL_UM&HL_US
When power 
booting at lower 
than 120
°C under 
LL environment
Upper heater lamp main/
sub
55
55
55
55
E
LL_120_ WUP_HL_LM
Lower heater lamp main 
60
60
60
60
F
LL_120_WUP_HL_EX
External heater lamp
45
45
45
45
G
HH_120_ 
WUP_HL_UM&HL_US
When power 
booting at lower 
than 120
°C under 
HH environment
Upper heater lamp main
55
50
55
50
H
HH_120_ WUP_HL_LM
Lower heater lamp main 
55
50
55
50
I
HH_120_WUP_HL_EX
External heater lamp
60
60
60
60
J
ON_120_WUP_HL_UM
Temperature 
correction value during 
temperature correction 
immediately after 
completion of warm-up
When power 
booting at lower 
than 120
°C
Upper heater lamp main
50
45
50
45
K
ON_120_WUP_HL_US
Lower heater lamp
65
65
65
65
L
ON_120_WUP_HL_EX
External heater lamp
50
50
50
50
M
NN_120_ 
FUS_DUP_HL_UM&HL_US
Fusing temperature 
correction value
When power 
booting at lower 
than 120
°C under 
NN environment
Upper heater lamp main
50
50
50
50
N
NN_120_ 
FUS_DUP_HL_LM
Lower heater lamp main
50
50
50
50
O
NN_120_FUS_DUP_HL_EX
External heater lamp
50
50
50
50
P
LL_120_ 
FUS_DUP_HL_UM&HL_US
When power 
booting at lower 
than 120
°C under 
LL environment
Upper heater lamp main/
sub
55
55
55
55
Q
LL_120_ FUS_DUP_HL_LM
Lower heater lamp main 
50
50
50
50
R
LL_120_FUS_DUP_HL_EX
External heater lamp
50
50
50
50
S
HH_120_ 
FUS_DUP_HL_UM&HL_US
When power 
booting at lower 
than 120
°C under 
HH environment
Upper heater lamp main/
sub
50
50
50
50
T
HH_120_ 
FUS_DUP_HL_LM
Lower heater lamp main
50
50
50
50
U
HH_120_FUS_DUP_HL_EX
External heater lamp
50
50
50
50
V
NN_120_ FUS_DUP_CNT
Fusing duplex paper 
exit count
Under NN environment
0
0
0
0
W
LL_120_ FUS_DUP_CNT
Under LL environment
0
0
0
0
X
HH_120_ FUS_DUP_CNT
Under HH environment
0
0
0
0
Page of 127