Sharp MX-6201N / MX-7001N (serv.man19) Service Manual ▷ View online
MX-7001N SIMULATION 7 – 49
H
HL_EX PLAIN
BW HH
BW HH
Correction value for
black and white plain
paper external
thermistor set value
under HH environment
black and white plain
paper external
thermistor set value
under HH environment
50
50
I
HL_UM PLAIN
CL HH
CL HH
Correction value for
color plain paper upper
thermistor main set
value under HH
environment
color plain paper upper
thermistor main set
value under HH
environment
45
45
J
HL_LM PLAIN
CL HH
CL HH
Correction value for HH
environment color plain
paper lower thermistor
main set value
environment color plain
paper lower thermistor
main set value
50
50
K
HL_US PLAIN
CL HH
CL HH
Correction value for
color plain paper upper
thermistor sub set value
under HH environment
color plain paper upper
thermistor sub set value
under HH environment
45
45
L
HL_EX PLAIN CL
HH
HH
Correction value for
color plain paper
external thermistor set
value under HH
environment
color plain paper
external thermistor set
value under HH
environment
50
50
M
WARMUP
FUMON HL_UM
T HH
FUMON HL_UM
T HH
Correction value for
fusing motor previous
rotation start external
thermistor set value
under HH environment
fusing motor previous
rotation start external
thermistor set value
under HH environment
50
50
N
WARMUP
FUMOFF HL_EX
TEMP HH
FUMOFF HL_EX
TEMP HH
Correction value for HH
environment fusing
motor front rotation
continuation time
environment fusing
motor front rotation
continuation time
50
50
O
WARMUP END
TIME HH
TIME HH
Correction value for
warm-up completion
time under HH
environment
warm-up completion
time under HH
environment
50
50
P
HL_UM HEAVY1
BW HH
BW HH
Correction value for HH
environment black and
white heavy paper 1
upper thermistor main
set value
environment black and
white heavy paper 1
upper thermistor main
set value
50
50
Q
HL_LM HEAVY1
BW HH
BW HH
Correction value for HH
environment black and
white heavy paper 1
lower thermistor main
set value
environment black and
white heavy paper 1
lower thermistor main
set value
50
50
R
HL_US HEAVY1
BW HH
BW HH
Correction value for HH
environment black and
white heavy paper 1
upper thermistor sub
set value
environment black and
white heavy paper 1
upper thermistor sub
set value
50
50
S
HL_EX HEAVY1
BW HH
BW HH
Correction value for HH
environment black and
white heavy paper 1
external thermistor set
value
environment black and
white heavy paper 1
external thermistor set
value
50
50
T
HL UM HEAVY1
CL HH
CL HH
Correction value for HH
environment heavy
paper 1 upper
thermistor main set
value
environment heavy
paper 1 upper
thermistor main set
value
50
50
U
HL LM HEAVY1
CL HH
CL HH
Correction value for HH
environment color
heavy paper 1 lower
thermistor main set
value
environment color
heavy paper 1 lower
thermistor main set
value
50
50
V
HL US HEAVY1
CL HH
CL HH
Correction value for HH
environment heavy
paper 1 upper
thermistor sub set value
environment heavy
paper 1 upper
thermistor sub set value
50
50
W
HL EX HEAVY1
CL HH
CL HH
Correction value for HH
environment color
heavy paper 1 external
thermistor set value
environment color
heavy paper 1 external
thermistor set value
50
50
Item
Default value
62-sheet
machine
machine
70-sheet
machine
machine
X
HL UM HEAVY2
BW HH
BW HH
Correction value for HH
environment black and
white heavy paper 2
upper thermistor main
set value
environment black and
white heavy paper 2
upper thermistor main
set value
50
50
Y
HL LM HEAVY2
BW HH
BW HH
Correction value for HH
environment black and
white heavy paper 2
lower thermistor main
set value
environment black and
white heavy paper 2
lower thermistor main
set value
50
50
Z
HL US HEAVY2
BW HH
BW HH
Correction value for HH
environment black and
white heavy paper 2
upper thermistor sub
set value
environment black and
white heavy paper 2
upper thermistor sub
set value
50
50
AA
HL EX HEAVY2
BW HH
BW HH
Correction value for HH
environment black and
white heavy paper 2
external thermistor set
value
environment black and
white heavy paper 2
external thermistor set
value
50
50
AB
HL UM HEAVY2
CL HH
CL HH
Correction value for HH
environment heavy
paper 2 upper
thermistor main set
value
environment heavy
paper 2 upper
thermistor main set
value
50
50
AC
HL LM HEAVY2
CL HH
CL HH
Correction value for HH
environment color
heavy paper 2 lower
thermistor main set
value
environment color
heavy paper 2 lower
thermistor main set
value
50
50
AD
HL US HEAVY2
CL HH
CL HH
Correction value for HH
environment heavy
paper 2 upper
thermistor sub set value
environment heavy
paper 2 upper
thermistor sub set value
50
50
AE
HL EX HEAVY2
CL HH
CL HH
Correction value for HH
environment color
heavy paper 2 external
thermistor set value
environment color
heavy paper 2 external
thermistor set value
50
50
AF
HL_UM OHP HH
Correction value for
OHP upper thermistor
main set value under
HH environment
OHP upper thermistor
main set value under
HH environment
50
50
AG
HL_LM OHP HH
Correction value for HH
environment OHP lower
thermistor mains et
value
environment OHP lower
thermistor mains et
value
50
50
AH
HL_US OHP HH
Correction value for
OHP upper thermistor
sub set value under HH
environment
OHP upper thermistor
sub set value under HH
environment
50
50
AI
HL_EX OHP HH
Correction value for
OHP external
thermistor set value
under HH environment
OHP external
thermistor set value
under HH environment
50
50
AJ
HL_UM
ENVELOPE HH
ENVELOPE HH
Correction value for
enveloper upper
thermistor main set
value under HH
environment
enveloper upper
thermistor main set
value under HH
environment
50
50
AK
HL_LM
ENVELOPE HH
ENVELOPE HH
Correction value for HH
environment envelope
lower thermistor main
set value
environment envelope
lower thermistor main
set value
50
50
AL
HL_US
ENVELOPE HH
ENVELOPE HH
Correction value for
enveloper upper
thermistor sub set value
under HH environment
enveloper upper
thermistor sub set value
under HH environment
50
50
AM
HL_EX
ENVELOPE HH
ENVELOPE HH
Correction value for
envelope external
thermistor set value
under HH environment
envelope external
thermistor set value
under HH environment
50
50
Item
Default value
62-sheet
machine
machine
70-sheet
machine
machine
MX-7001N SIMULATION 7 – 50
43-22
Purpose
Adjustment/Setting
Function (Purpose) Used to set the environment correction
under low temperature and low humidity (L/
L) for the fusing temperature setting (SIM
43-4) in each paper mode.
L) for the fusing temperature setting (SIM
43-4) in each paper mode.
Section
Operation/Procedure
1)
1)
Select an item to be set with [
↑] and [↓] keys.
2)
Enter the adjustment value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved.
The set value in step 2 is saved.
Correction value: -49 to +49, 1 count = 1
°C change
AN
HL_UM E-STAR
HH
HH
Correction value for
upper thermistor main
set value when
preheating under HH
environment
upper thermistor main
set value when
preheating under HH
environment
50
50
AO
HL US E-STAR
HH
HH
Correction value for HH
environment preheating
upper thermistor sub
set value
environment preheating
upper thermistor sub
set value
50
50
AP
HL EX E-STAR
HH
HH
Correction value for HH
environment preheating
external thermistor set
value
environment preheating
external thermistor set
value
50
50
AQ
HL_UM PRE-
JOB HH
JOB HH
Correction value for
upper thermistor main
set value when
recovering from
preheating under HH
environment
upper thermistor main
set value when
recovering from
preheating under HH
environment
50
50
AR
HL UM THIN
PAPER BW HH
PAPER BW HH
Correction value for HH
environment black and
white thin paper upper
thermistor main set
value
environment black and
white thin paper upper
thermistor main set
value
45
45
AS
HL LM THIN
PAPER BW HH
PAPER BW HH
Correction value for HH
environment black and
white thin paper lower
thermistor main set
value
environment black and
white thin paper lower
thermistor main set
value
45
45
AT
HL US THIN
PAPER BW HH
PAPER BW HH
Correction value for HH
environment black and
white thin paper upper
thermistor sub set value
environment black and
white thin paper upper
thermistor sub set value
45
45
AU
HL EX THIN
PAPER BW HH
PAPER BW HH
Correction value for HH
environment black and
white thin paper
external thermistor set
value
environment black and
white thin paper
external thermistor set
value
45
45
AV
HL UM THIN
PAPER CL HH
PAPER CL HH
Correction value for HH
environment color thin
paper upper thermistor
main set value
environment color thin
paper upper thermistor
main set value
45
45
AW
HL LM THIN
PAPER CL HH
PAPER CL HH
Correction value for HH
environment color thin
paper lower thermistor
main set value
environment color thin
paper lower thermistor
main set value
45
45
AX
HL US THIN
PAPER CL HH
PAPER CL HH
Correction value for HH
environment color thin
paper upper thermistor
sub set value
environment color thin
paper upper thermistor
sub set value
45
45
AY
HL EX THIN
PAPER CL HH
PAPER CL HH
Correction value for HH
environment color thin
paper external
thermistor set value
environment color thin
paper external
thermistor set value
45
45
AZ
HL UM THIN
PAPER READY
HH
PAPER READY
HH
Correction value for HH
environment thin paper
ready upper thermistor
main temperature value
environment thin paper
ready upper thermistor
main temperature value
45
45
BA
HL UM REC
PAPER BW HH
PAPER BW HH
Correction value for HH
environment black and
white recycled paper
upper thermistor main
set value
environment black and
white recycled paper
upper thermistor main
set value
45
45
BB
HL LM REC
PAPER BW HH
PAPER BW HH
Correction value for HH
environment black and
white recycled paper
lower thermistor main
set value
environment black and
white recycled paper
lower thermistor main
set value
45
45
BC
HL US REC
PAPER BW HH
PAPER BW HH
Correction value for HH
environment black and
white recycled paper
upper thermistor sub
set value
environment black and
white recycled paper
upper thermistor sub
set value
45
45
Item
Default value
62-sheet
machine
machine
70-sheet
machine
machine
BD
HL EX REC
PAPER BW HH
PAPER BW HH
Correction value for HH
environment black and
white recycled paper
external thermistor set
value
environment black and
white recycled paper
external thermistor set
value
45
45
BE
HL UM REC
PAPER CL HH
PAPER CL HH
Correction value for HH
environment color
recycled paper upper
thermistor main set
value
environment color
recycled paper upper
thermistor main set
value
45
45
BF
HL LM REC
PAPER CL HH
PAPER CL HH
Correction value for HH
environment color
recycled paper lower
thermistor main set
value
environment color
recycled paper lower
thermistor main set
value
45
45
BG
HL US REC
PAPER CL HH
PAPER CL HH
Correction value for HH
environment color
recycled paper upper
thermistor sub set value
environment color
recycled paper upper
thermistor sub set value
45
45
BH
HL EX REC
PAPER CL HH
PAPER CL HH
Correction value for HH
environment color
recycled paper external
thermistor set value
environment color
recycled paper external
thermistor set value
45
45
BI
HL UM REC
PAPER READY
HH
PAPER READY
HH
Correction value for HH
environment recycled
paper ready upper
thermistor main
temperature value
environment recycled
paper ready upper
thermistor main
temperature value
45
45
Item
Default
value
A
HL_UM PLAIN
BW DUP LL
BW DUP LL
Correction value for black and white
plain paper duplex upper thermistor
main set value under LL environment
plain paper duplex upper thermistor
main set value under LL environment
50
B
HL_LM PLAIN
BW DUP LL
BW DUP LL
Correction value for LL environment
black and white plain paper duplex
lower thermistor main set value
black and white plain paper duplex
lower thermistor main set value
50
Item
Default value
62-sheet
machine
machine
70-sheet
machine
machine
A㧦 40
㧧
HL_UM READY HH
B㧦 50
㧧
HL_LM READY HH
C㧦40
㧧
HL_US READY HH
D㧦45
㧧
HL_EX READY HH
A:
SIMULATION NO.43㧙21
FUSER TEMP ADJUSTMENT (HH)
40
㨇
1 㨪 99㨉
OK
TEST
CLOSE
E㧦40
㧧
HL_UM PLAIN BW HH
F㧦50
㧧
HL_LM PLAIN BW HH
G㧦40
㧧
HL_US PLAIN BW HH
H㧦50
㧧
HL_EX PLAIN BW HH
I㧦 40
㧧
HL_UM PLAIN CL HH
J㧦 50
㧧
HL_LM PLAIN CL HH
K㧦40
㧧
HL_US PLAIN CL HH
L㧦 50
㧧
HL_EX PLAIN CL HH
MX-7001N SIMULATION 7 – 51
43-23
Purpose
Adjustment/Setting
Function (Purpose) Used to set the environment correction
under high temperature and high humidity
(H/H) for the fusing temperature setting
(SIM 43-4) in each paper mode.
(H/H) for the fusing temperature setting
(SIM 43-4) in each paper mode.
Section
Operation/Procedure
1)
1)
Select an item to be set with [
↑] and [↓] keys.
2)
Enter the adjustment value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved.
The set value in step 2 is saved.
Correction value: -49 to +49, 1 count = 1
°C change
C
HL_US PLAIN
BW DUP LL
BW DUP LL
Correction value for black and white
plain paper duplex upper thermistor
sub set value under LL environment
plain paper duplex upper thermistor
sub set value under LL environment
50
D
HL_EX PLAIN
BW DUP LL
BW DUP LL
Correction value for black and white
plain paper duplex external thermistor
set value under LL environment
plain paper duplex external thermistor
set value under LL environment
50
E
PLAIN BW DUP
APP CNT LL
APP CNT LL
Correction value for black and white
plain paper duplex applicable number
of sheets under LL environment
plain paper duplex applicable number
of sheets under LL environment
50
F
HL_UM PLAIN
CL DUP LL
CL DUP LL
Correction value for color plain paper
duplex upper thermistor main set value
under LL environment
duplex upper thermistor main set value
under LL environment
50
G
HL_LM PLAIN
CL DUP LL
CL DUP LL
Correction value for LL environment
color plain paper duplex lower
thermistor main set value
color plain paper duplex lower
thermistor main set value
50
H
HL_US PLAIN
CL DUP LL
CL DUP LL
Correction value for color plain paper
duplex upper thermistor sub set value
under LL environment
duplex upper thermistor sub set value
under LL environment
50
I
HL_EX PLAIN
CL DUP LL
CL DUP LL
Correction value for color plain paper
duplex external thermistor set value
under LL environment
duplex external thermistor set value
under LL environment
55
J
PLAIN CL DUP
APP CNT LL
APP CNT LL
Correction value for color plain paper
duplex applicable number of sheets
under LL environment
duplex applicable number of sheets
under LL environment
50
K
HL_UM HEAVY
BW DUP LL
BW DUP LL
Correction value for black and white
heavy paper duplex upper thermistor
main set value under LL environment
heavy paper duplex upper thermistor
main set value under LL environment
50
L
HL_LM HEAVY
BW DUP LL
BW DUP LL
Correction value for LL environment
black and white duplex lower thermistor
main set value
black and white duplex lower thermistor
main set value
50
M
HL_US HEAVY
BW DUP LL
BW DUP LL
Correction value for black and white
heavy paper duplex upper thermistor
sub set value under LL environment
heavy paper duplex upper thermistor
sub set value under LL environment
50
N
HL_EX HEAVY
BW DUP LL
BW DUP LL
Correction value for black and white
heavy paper duplex external thermistor
set value under LL environment
heavy paper duplex external thermistor
set value under LL environment
50
O
HEAVY BW
DUP APP CNT
LL
DUP APP CNT
LL
Correction value for black and white
heavy paper duplex applicable number
of sheets under LL environment
heavy paper duplex applicable number
of sheets under LL environment
50
P
HL_UM HEAVY
CL DUP LL
CL DUP LL
Correction value for color heavy paper
duplex upper thermistor main set value
under LL environment
duplex upper thermistor main set value
under LL environment
50
Q
HL_LM HEAVY
CL DUP LL
CL DUP LL
Correction value for LL environment
black and white heavy paper duplex
lower thermistor main set value
black and white heavy paper duplex
lower thermistor main set value
50
R
HL_US HEAVY
CL DUP LL
CL DUP LL
Correction value for color heavy paper
duplex upper thermistor sub set value
under LL environment
duplex upper thermistor sub set value
under LL environment
50
S
HL_EX HEAVY
CL DUP LL
CL DUP LL
Correction value for color heavy paper
duplex external thermistor set value
under LL environment
duplex external thermistor set value
under LL environment
50
T
HEAVY CL DUP
APP CNT LL
APP CNT LL
Correction value for color heavy paper
duplex applicable number of sheets
under LL environment
duplex applicable number of sheets
under LL environment
50
Item
Default
value
A : 60
;
HL_UM PLAIN BW DUP LL
B : 60
;
HL_LM PLAIN BW DUP LL
C : 60
;
HL_US PLAIN BW DUP LL
D : 50
;
HL_EX PLAIN BW DUP LL
A:
SIMULATION NO.43-22
FUSER TEMP ADJUSTMENT (LL:DUP)
60
1
99
OK
TEST
CLOSE
E : 50
;
PLAIN BW DUP APP CNT LL
F : 55
;
HL_UM PLAIN CL DUP LL
G : 55
;
HL_LM PLAIN CL DUP LL
H : 55
;
HL_US PLAIN CL DUP LL
I : 55
;
HL_EX PLAIN CL DUP LL
J : 50
;
PLAIN CL DUP APP CNT LL
K : 60
;
HL_UM HEAVY BW DUP LL
L : 60
;
HL_LM HEAVY BW DUP LL
Item
Default value
62 sheet
machine
machine
70 sheet
machine
machine
A
HL_UM
PLAIN BW
DUP HH
PLAIN BW
DUP HH
Correction value for black and
white upper thermistor main
set value under HH
environment
white upper thermistor main
set value under HH
environment
50
40
B
HL_LM
PLAIN BW
DUP HH
PLAIN BW
DUP HH
Correction value for HH
environment black and white
plain paper duplex lower
thermistor main set value
environment black and white
plain paper duplex lower
thermistor main set value
50
50
C
HL_US
PLAIN BW
DUP HH
PLAIN BW
DUP HH
Correction value for black and
white upper thermistor sub set
value under HH environment
white upper thermistor sub set
value under HH environment
50
45
D
HL_EX
PLAIN BW
DUP HH
PLAIN BW
DUP HH
Correction value for black and
white plain paper duplex
external thermistor set value
under HH environment
white plain paper duplex
external thermistor set value
under HH environment
50
50
E
PLAIN BW
DUP APP
CNT HH
DUP APP
CNT HH
Correction value for black and
white plain paper duplex
applicable number of sheets
under HH environment
white plain paper duplex
applicable number of sheets
under HH environment
50
50
F
HL_UM
PLAIN CL
DUP HH
PLAIN CL
DUP HH
Correction value for color plain
paper duplex upper thermistor
main set value under HH
environment
paper duplex upper thermistor
main set value under HH
environment
50
50
G
HL_LM
PLAIN CL
DUP HH
PLAIN CL
DUP HH
Correction value for HH
environment color plain paper
duplex lower thermistor main
set value
environment color plain paper
duplex lower thermistor main
set value
50
50
H
HL_US
PLAIN CL
DUP HH
PLAIN CL
DUP HH
Correction value for color plain
paper duplex upper thermistor
sub set value under HH
environment
paper duplex upper thermistor
sub set value under HH
environment
50
50
I
HL_EX
PLAIN CL
DUP HH
PLAIN CL
DUP HH
Correction value for color plain
paper duplex external
thermistor set value under HH
environment
paper duplex external
thermistor set value under HH
environment
50
50
J
PLAIN CL
DUP APP
CNT HH
DUP APP
CNT HH
Correction value for color plain
paper duplex applicable
number of sheets under HH
environment
paper duplex applicable
number of sheets under HH
environment
50
50
K
HL_UM
HEAVY BW
DUP HH
HEAVY BW
DUP HH
Correction value for black and
white heavy paper duplex
upper thermistor main set
value under HH environment
white heavy paper duplex
upper thermistor main set
value under HH environment
50
50
L
HL_LM
HEAVY BW
DUP HH
HEAVY BW
DUP HH
Correction value for HH
environment black and white
duplex lower thermistor main
set value
environment black and white
duplex lower thermistor main
set value
50
50
M
HL_US
HEAVY BW
DUP HH
HEAVY BW
DUP HH
Correction value for black and
white heavy paper duplex
upper thermistor sub set value
under HH environment
white heavy paper duplex
upper thermistor sub set value
under HH environment
50
50
N
HL_EX
HEAVY BW
DUP HH
HEAVY BW
DUP HH
Correction value for black and
white heavy paper duplex
external thermistor set value
under HH environment
white heavy paper duplex
external thermistor set value
under HH environment
50
50
MX-7001N SIMULATION 7 – 52
43-24
Purpose
Adjustment/Setting
Function (Purpose) Used to set the correction of the tempera-
ture adjustment value of SIM 43-1 and 43-
4.
4.
Section
Operation/Procedure
1)
1)
Select an item to be set with [
↑] and [↓] keys.
2)
Enter the adjustment value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved.
The set value in step 2 is saved.
Correction value: -49 to +49, 1 count = 1
°C change
O
HEAVY BW
DUP APP
CNT HH
DUP APP
CNT HH
Correction value for black and
white heavy paper duplex
applicable number of sheets
under HH environment
white heavy paper duplex
applicable number of sheets
under HH environment
50
50
P
HL_UM
HEAVY CL
DUP HH
HEAVY CL
DUP HH
Correction value for color
heavy paper duplex upper
thermistor main set value
under HH environment
heavy paper duplex upper
thermistor main set value
under HH environment
50
50
Q
HL_LM
HEAVY CL
DUP HH
HEAVY CL
DUP HH
Correction value for HH
environment black and white
heavy paper duplex lower
thermistor main set value
environment black and white
heavy paper duplex lower
thermistor main set value
50
50
R
HL_US
HEAVY CL
DUP HH
HEAVY CL
DUP HH
Correction value for color
heavy paper duplex upper
thermistor sub set value under
HH environment
heavy paper duplex upper
thermistor sub set value under
HH environment
50
50
S
HL_EX
HEAVY CL
DUP HH
HEAVY CL
DUP HH
Correction value for color
heavy paper duplex external
thermistor set value under HH
environment
heavy paper duplex external
thermistor set value under HH
environment
50
50
T
HEAVY CL
DUP APP
CNT HH
DUP APP
CNT HH
Correction value for color
heavy paper duplex applicable
number of sheets under HH
environment
heavy paper duplex applicable
number of sheets under HH
environment
50
50
Item
Default value
62 sheet
machine
machine
70 sheet
machine
machine
A㧦 50
㧧
HL_UM PLAIN BW DUP HH
B㧦 50
㧧
HL_LM PLAIN BW DUP HH
C㧦50
㧧
HL_US PLAIN BW DUP HH
D㧦50
㧧
HL_EX PLAIN BW DUP HH
A:
SIMULATION NO.43-23
FUSER TEMP ADJUSTMENT (HH:DUP)
50
㨇
1 㨪 99㨉
OK
TEST
CLOSE
E㧦50
㧧
PLAIN BW DUP APP CNT HH
F㧦50
㧧
HL_UM PLAIN CL DUP HH
G㧦50
㧧
HL_LM PLAIN CL DUP HH
H㧦50
㧧
HL_US PLAIN CL DUP HH
I㧦 50
㧧
HL_EX PLAIN CL DUP HH
J㧦 50
㧧
PLAIN CL DUP APP CNT HH
K㧦50
㧧
HL_UM HEAVY BW DUP HH
L㧦 50
㧧
HL_LM HEAVY BW DUP HH
Item
Default value
100V series
200V series
62-sheet
machine
machine
70-sheet
machine
machine
62-sheet
machine
machine
70-sheet
machine
machine
A
NN_120_
WUP_HL_UM&HL_US
WUP_HL_UM&HL_US
Warm-up completion
temperature correction
value
When power
booting at lower
than 120
booting at lower
than 120
°C under
NN environment
Upper heater lamp main/
sub
sub
55
50
55
50
B
NN_120_ WUP_HL_LM
Lower heater lamp main
50
45
50
45
C
NN_120_WUP_HL_EX
External heater lamp main
50
50
50
50
D
LL_120_
WUP_HL_UM&HL_US
WUP_HL_UM&HL_US
When power
booting at lower
than 120
booting at lower
than 120
°C under
LL environment
Upper heater lamp main/
sub
sub
55
55
55
55
E
LL_120_ WUP_HL_LM
Lower heater lamp main
60
60
60
60
F
LL_120_WUP_HL_EX
External heater lamp
45
45
45
45
G
HH_120_
WUP_HL_UM&HL_US
WUP_HL_UM&HL_US
When power
booting at lower
than 120
booting at lower
than 120
°C under
HH environment
Upper heater lamp main
55
50
55
50
H
HH_120_ WUP_HL_LM
Lower heater lamp main
55
50
55
50
I
HH_120_WUP_HL_EX
External heater lamp
60
60
60
60
J
ON_120_WUP_HL_UM
Temperature
correction value during
temperature correction
temperature correction
immediately after
completion of warm-up
When power
booting at lower
than 120
booting at lower
than 120
°C
Upper heater lamp main
50
45
50
45
K
ON_120_WUP_HL_US
Lower heater lamp
65
65
65
65
L
ON_120_WUP_HL_EX
External heater lamp
50
50
50
50
M
NN_120_
FUS_DUP_HL_UM&HL_US
FUS_DUP_HL_UM&HL_US
Fusing temperature
correction value
When power
booting at lower
than 120
booting at lower
than 120
°C under
NN environment
Upper heater lamp main
50
50
50
50
N
NN_120_
FUS_DUP_HL_LM
FUS_DUP_HL_LM
Lower heater lamp main
50
50
50
50
O
NN_120_FUS_DUP_HL_EX
External heater lamp
50
50
50
50
P
LL_120_
FUS_DUP_HL_UM&HL_US
FUS_DUP_HL_UM&HL_US
When power
booting at lower
than 120
booting at lower
than 120
°C under
LL environment
Upper heater lamp main/
sub
sub
55
55
55
55
Q
LL_120_ FUS_DUP_HL_LM
Lower heater lamp main
50
50
50
50
R
LL_120_FUS_DUP_HL_EX
External heater lamp
50
50
50
50
S
HH_120_
FUS_DUP_HL_UM&HL_US
FUS_DUP_HL_UM&HL_US
When power
booting at lower
than 120
booting at lower
than 120
°C under
HH environment
Upper heater lamp main/
sub
sub
50
50
50
50
T
HH_120_
FUS_DUP_HL_LM
FUS_DUP_HL_LM
Lower heater lamp main
50
50
50
50
U
HH_120_FUS_DUP_HL_EX
External heater lamp
50
50
50
50
V
NN_120_ FUS_DUP_CNT
Fusing duplex paper
exit count
Under NN environment
0
0
0
0
W
LL_120_ FUS_DUP_CNT
Under LL environment
0
0
0
0
X
HH_120_ FUS_DUP_CNT
Under HH environment
0
0
0
0
Click on the first or last page to see other MX-6201N / MX-7001N (serv.man19) service manuals if exist.