Sharp MX-6201N / MX-7001N (serv.man19) Service Manual ▷ View online
MX-7001N SIMULATION 7 – 45
43-4
Purpose
Setting
Function (Purpose) Used to perform the fusing temperature
setup 2 in each operation mode. (Contin-
ued from SIM 43-1.)
ued from SIM 43-1.)
Section
Operation/Procedure
1)
1)
Select an item to be set with [
↑] and [↓] keys.
2)
Enter the adjustment value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved.
The set value in step 2 is saved.
AI
HL_EX OHP
PAPER
PAPER
OHP external thermistor
set value
set value
220
220
AJ
HL_UM ENV
PAPER
PAPER
Envelope upper
thermistor main set
value
thermistor main set
value
200
200
AK
HL_LM ENV
PAPER
PAPER
Envelope lower
thermistor main set
value
thermistor main set
value
150
150
AL
HL_US ENV
PAPER
PAPER
Envelope upper
thermistor sub set value
thermistor sub set value
180
180
AM
HL_EX ENV
PAPER
PAPER
Envelope external
thermistor set value
thermistor set value
220
220
AN
HL_UM E-STAR
Upper thermistor main
set value when
preheating
set value when
preheating
173
178
AO
HL_US E-STAR
Preheating upper
thermistor sub set value
thermistor sub set value
160
160
AP
HL_EX E-STAR
Preheating external
thermistor sub set value
thermistor sub set value
180
195
AQ
HL_UM PRE-
JOB
JOB
Upper thermistor main
set value when
recovering from
preheating
set value when
recovering from
preheating
190
200
AR
HL UM THIN
PAPER BW
PAPER BW
Black and white thin
paper upper thermistor
main set value
paper upper thermistor
main set value
165
165
AS
HL LM THIN
PAPER BW
PAPER BW
Black and white thin
paper lower thermistor
main set value
paper lower thermistor
main set value
130
130
AT
HL US THIN
PAPER BW
PAPER BW
Black and white thin
paper upper thermistor
sub set value
paper upper thermistor
sub set value
165
165
AU
HL EX THIN
PAPER BW
PAPER BW
Black and white external
thermistor set value
thermistor set value
195
195
AV
HL UM THIN
PAPER CL
PAPER CL
Color thin paper upper
thermistor main set
value
thermistor main set
value
165
165
AW
HL LM THIN
PAPER CL
PAPER CL
Color thin paper lower
thermistor main set
value
thermistor main set
value
120
120
AX
HL US THIN
PAPER CL
PAPER CL
Color thin paper upper
thermistor sub set value
thermistor sub set value
165
165
AY
HL EX THIN
PAPER CL
PAPER CL
Color thin paper external
thermistor set value
thermistor set value
195
195
AZ
HL UM THIN
PAPER READY
PAPER READY
Thin paper ready upper
thermistor main set
value
thermistor main set
value
170
170
BA
HL UM REC
PAPER BW
PAPER BW
Black and white recycled
paper upper thermistor
main set value
paper upper thermistor
main set value
180
180
BB
HL LM REC
PAPER BW
PAPER BW
Black and white recycled
paper lower thermistor
main set value
paper lower thermistor
main set value
145
145
BC
HL US REC
PAPER BW
PAPER BW
Black and white recycled
paper upper thermistor
sub set value
paper upper thermistor
sub set value
170
170
BD
HL EX REC
PAPER BW
PAPER BW
Black and white recycled
paper external
thermistor main set
value
paper external
thermistor main set
value
220
220
BE
HL UM REC
PAPER CL
PAPER CL
Color recycled paper
upper thermistor main
set value
upper thermistor main
set value
165
165
BF
HL LM REC
PAPER CL
PAPER CL
Color recycled paper
lower thermistor main
set value
lower thermistor main
set value
130
130
BG
HL US REC
PAPER CL
PAPER CL
Color recycled paper
upper thermistor sub set
value
upper thermistor sub set
value
165
165
BH
HL EX REC
PAPER CL
PAPER CL
Color recycled paper
external thermistor set
value
external thermistor set
value
195
195
Item
Default value
62-sheet
machine
machine
70-sheet
machine
machine
BI
HL UM REC
PAPER READY
PAPER READY
Recycled paper reed
upper thermistor main
temperature value
upper thermistor main
temperature value
180
180
BJ
COOL DOWN
CTRL
CTRL
Cool down YES/NO
1
1
Item
Default value
62-sheet
machine
machine
70-sheet
machine
machine
A
HL_UM PLAIN
PAPER BW DUP
PAPER BW DUP
Black and white plain
paper duplex upper
thermistor main set
value
paper duplex upper
thermistor main set
value
185
190
B
HL_LM PLAIN
PAPER BW DUP
PAPER BW DUP
Black and white plain
paper duplex lower
thermistor main set
value
paper duplex lower
thermistor main set
value
150
155
C
HL_US PLAIN
PAPER BW DUP
PAPER BW DUP
Black and white plain
paper duplex upper
thermistor sub set value
paper duplex upper
thermistor sub set value
175
180
D
HL_EX PLAIN
PAPER BW DUP
PAPER BW DUP
Black and white plain
paper duplex external
thermistor set value
paper duplex external
thermistor set value
220
220
E
PLAIN PAPER BW
DUP APP CNT
DUP APP CNT
Black and white plain
paper duplex external
thermistor set value
paper duplex external
thermistor set value
1
1
F
HL_UM PLAIN
PAPER CL DUP
PAPER CL DUP
Color plain paper
duplex upper thermistor
main set value
duplex upper thermistor
main set value
185
185
G
HL_LM PLAIN
PAPER CL DUP
PAPER CL DUP
Color plain paper
duplex lower thermistor
main set value
duplex lower thermistor
main set value
150
150
H
HL_US PLAIN
PAPER CL DUP
PAPER CL DUP
Color plain paper
duplex upper thermistor
sub set value
duplex upper thermistor
sub set value
180
180
I
HL_EX PLAIN
PAPER CL DUP
PAPER CL DUP
Color plain paper
duplex external
thermistor set value
duplex external
thermistor set value
210
210
Item
Default value
62-sheet
machine
machine
70-sheet
machine
machine
A㧦180
㧧
HL_UM READY
B㧦125
㧧
HL_LM READY
C㧦150
㧧
HL_US READY
D㧦200
㧧
HL_EX READY
A:
SIMULATION NO.43㧙01
FUSER TEMP SETUP FOR PAPER
180
㨇
70 㨪 230㨉
OK
TEST
CLOSE
E㧦185
㧧
HL_UM PLAIN PAPER BW
F㧦140
㧧
HL_LM PLAIN PAPER BW
G㧦175
㧧
HL_US PLAIN PAPER BW
H㧦210
㧧
HL_EX PLAIN PAPER BW
I㧦190
㧧
HL_UM PLAIN PAPER CL
J㧦125
㧧
HL_LM PLAIN PAPER CL
K㧦180
㧧
HL_US PLAIN PAPER CL
L㧦205
㧧
HL_EX PLAIN PAPER CL
MX-7001N SIMULATION 7 – 46
43-20
Purpose
Adjustment/Setting
Function (Purpose) Used to set the environmental correction
under low temperature and low humidity (L/
L) for the fusing temperature setting in each
mode (SIM 43-1).
L) for the fusing temperature setting in each
mode (SIM 43-1).
Section
Operation/Procedure
1)
1)
Select an item to be set with [
↑] and [↓] keys.
2)
Enter the adjustment value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved.
The set value in step 2 is saved.
Correction value: -49 to +49, 1 count = 1
°C change
J
PLAIN PAPER CL
DUP APP CNT
DUP APP CNT
Color plain paper
duplex applicable
number of sheets
duplex applicable
number of sheets
0
0
K
HL_UM HEAVY
PAPER BW DUP
PAPER BW DUP
Black and white heavy
paper duplex upper
thermistor main set
value
paper duplex upper
thermistor main set
value
180
180
L
HL_LM HEAVY
PAPER BW DUP
PAPER BW DUP
Black and white heavy
paper duplex lower
thermistor main set
value
paper duplex lower
thermistor main set
value
130
130
M
HL_US HEAVY
PAPER BW DUP
PAPER BW DUP
Black and white heavy
paper duplex upper
thermistor sub set value
paper duplex upper
thermistor sub set value
180
180
N
HL_EX HEAVY
PAPER BW DUP
PAPER BW DUP
Black and white heavy
paper duplex external
thermistor set value
paper duplex external
thermistor set value
220
220
O
HEAVY PAPER
BW DUP APP
CNT
BW DUP APP
CNT
Black and white heavy
paper duplex applicable
number of sheets
paper duplex applicable
number of sheets
1
1
P
HL_UM HEAVY
PAPER CL DUP
PAPER CL DUP
Color heavy paper
duplex upper thermistor
main set value
duplex upper thermistor
main set value
170
170
Q
HL_LM HEAVY
PAPER CL DUP
PAPER CL DUP
Color heavy paper
duplex lower thermistor
main set value
duplex lower thermistor
main set value
120
120
R
HL_US HEAVY
PAPER CL DUP
PAPER CL DUP
Color heavy paper
duplex upper thermistor
sub set value
duplex upper thermistor
sub set value
170
170
S
HL_EX HEAVY
PAPER CL DUP
PAPER CL DUP
Color heavy paper
duplex external
thermistor set value
duplex external
thermistor set value
200
200
T
HEAVY PAPER
CL DUP APP CNT
CL DUP APP CNT
Color heavy paper
duplex applicable
number of sheets.
duplex applicable
number of sheets.
1
1
Item
Default value
62-sheet
machine
machine
70-sheet
machine
machine
A㧦180
㧧
HL_UM PLAIN PAPER BW DUP
B㧦150
㧧
HL_LM PLAIN PAPER BW DUP
C㧦170
㧧
HL_US PLAIN PAPER
D㧦220
㧧
HL_EX PLAIN PAPER BW DUP
A:
SIMULATION NO.43㧙04
FUSER TEMP SETUP FOR PAPER
180
㨇
70 㨪 230㨉
OK
TEST
CLOSE
E㧦 1
㧧
PLAIN PAPER BW DUP APP CNT
F㧦180
㧧
HL_UM PLAIN PAPER CL DUP
G㧦145
㧧
HL_LM PLAIN PAPER CL DUP
H㧦175
㧧
HL_US PLAIN PAPER CL DUP
I㧦200
㧧
HL_E PLAIN PAPER CL DUP
J㧦 0
㧧
PLAIN PAPER CL DUP APP CNT
K㧦180
㧧
HL_UM HEAVY PAPER BW DUP
L㧦130
㧧
HL_LM HEAVY PAPER BW DUP
Item
Default value
62-sheet
machine
machine
70-sheet
machine
machine
A
HL_UM READY
LL
LL
Correction value for
upper thermistor main
set value when ready
under LL environment
upper thermistor main
set value when ready
under LL environment
65
55
B
HL_LM READY
LL
LL
Correction value for LL
environment ready
standby lower
thermistor main set
value
environment ready
standby lower
thermistor main set
value
65
65
C
HL_US READY
LL
LL
Correction value for
upper thermistor sub
set value when ready
under LL environment
upper thermistor sub
set value when ready
under LL environment
65
65
D
HL_EX READY
LL
LL
Correction value for
external thermistor set
value when ready under
LL environment
external thermistor set
value when ready under
LL environment
55
55
E
HL_UM PLAIN
BW LL
BW LL
Correction value for
black and white plain
paper upper thermistor
main set value under LL
environment
black and white plain
paper upper thermistor
main set value under LL
environment
60
55
F
HL_LM PLAIN
BW LL
BW LL
Correction value for LL
environment black and
white plain paper lower
thermistor main set
value
environment black and
white plain paper lower
thermistor main set
value
65
65
G
HL_US PLAIN
BW LL
BW LL
Correction value for
black and white plain
paper upper thermistor
sub set value under LL
environment
black and white plain
paper upper thermistor
sub set value under LL
environment
55
50
H
HL_EX PLAIN
BW LL
BW LL
Correction value for
black and white plain
paper external
thermistor set value
under LL environment
black and white plain
paper external
thermistor set value
under LL environment
55
55
I
HL_UM PLAIN
CL LL
CL LL
Correction value for
color plain paper upper
thermistor main set
value under LL
environment
color plain paper upper
thermistor main set
value under LL
environment
55
55
J
HL_LM PLAIN CL
LL
LL
Correction value for LL
environment color plain
paper lower thermistor
main set value
environment color plain
paper lower thermistor
main set value
60
60
K
HL_US PLAIN CL
LL
LL
Correction value for
color plain paper upper
thermistor sub set value
under LL environment
color plain paper upper
thermistor sub set value
under LL environment
50
50
L
HL_EX PLAIN CL
LL
LL
Correction value for
color plain paper
external thermistor set
value under LL
environment
color plain paper
external thermistor set
value under LL
environment
65
65
M
WARMUP
FUMON HL_EX
TEMP LL
FUMON HL_EX
TEMP LL
Correction value for LL
environment fusing
motor front rotation start
external thermistor set
value
environment fusing
motor front rotation start
external thermistor set
value
40
40
N
WARMUP
FUMOFF TIME
LL
FUMOFF TIME
LL
Correction value for LL
environment fusing
motor front rotation
continuation time
environment fusing
motor front rotation
continuation time
80
80
O
WARMUP END
TIME LL
TIME LL
Correction value for
warm-up completion
time under LL
environment
warm-up completion
time under LL
environment
75
75
P
HL_UM HEAVY1
BW LL
BW LL
Correction value for LL
environment black and
white heavy paper 1
upper thermistor main
set value
environment black and
white heavy paper 1
upper thermistor main
set value
65
65
MX-7001N SIMULATION 7 – 47
Q
HL_LM HEAVY1
BW LL
BW LL
Correction value for LL
environment black and
white heavy paper 1
lower thermistor main
set value
environment black and
white heavy paper 1
lower thermistor main
set value
65
65
R
HL_US HEAVY1
BW LL
BW LL
Correction value for LL
environment black and
white heavy paper 1
upper thermistor sub
set value
environment black and
white heavy paper 1
upper thermistor sub
set value
65
65
S
HL_EX HEAVY1
BW LL
BW LL
Correction value for LL
environment black and
white heavy paper 1
external thermistor set
value
environment black and
white heavy paper 1
external thermistor set
value
50
50
T
HL UM HEAVY1
CL LL
CL LL
Correction value for LL
environment heavy
paper 1 upper
thermistor main set
value
environment heavy
paper 1 upper
thermistor main set
value
60
60
U
HL LM HEAVY1
CL LL
CL LL
Correction value for LL
environment color
heavy paper 1 lower
thermistor main set
value
environment color
heavy paper 1 lower
thermistor main set
value
65
65
V
HL US HEAVY1
CL LL
CL LL
Correction value for LL
environment heavy
paper 1 upper
thermistor sub set value
environment heavy
paper 1 upper
thermistor sub set value
60
60
W
HL EX HEAVY1
CL LL
CL LL
Correction value for LL
environment color
heavy paper 1 external
thermistor set value
environment color
heavy paper 1 external
thermistor set value
65
65
X
HL UM HEAVY2
BW LL
BW LL
Correction value for LL
environment black and
white heavy paper 2
upper thermistor main
set value
environment black and
white heavy paper 2
upper thermistor main
set value
65
65
Y
HL LM HEAVY2
BW LL
BW LL
Correction value for LL
environment black and
white heavy paper 2
lower thermistor main
set value
environment black and
white heavy paper 2
lower thermistor main
set value
65
65
Z
HL US HEAVY2
BW LL
BW LL
Correction value for LL
environment black and
white heavy paper 2
upper thermistor sub
set value
environment black and
white heavy paper 2
upper thermistor sub
set value
65
65
AA
HL EX HEAVY2
BW LL
BW LL
Correction value for LL
environment black and
white heavy paper 2
external thermistor set
value
environment black and
white heavy paper 2
external thermistor set
value
50
50
AB
HL UM HEAVY2
CL LL
CL LL
Correction value for LL
environment heavy
paper 2 upper
thermistor main set
value
environment heavy
paper 2 upper
thermistor main set
value
65
65
AC
HL LM HEAVY2
CL LL
CL LL
Correction value for LL
environment color
heavy paper 2 lower
thermistor main set
value
environment color
heavy paper 2 lower
thermistor main set
value
65
65
AD
HL US HEAVY2
CL LL
CL LL
Correction value for LL
environment heavy
paper 2 upper
thermistor sub set value
environment heavy
paper 2 upper
thermistor sub set value
65
65
AE
HL EX HEAVY2
CL LL
CL LL
Correction value for LL
environment color
heavy paper 2 external
thermistor set value
environment color
heavy paper 2 external
thermistor set value
60
60
AF
HL_UM OHP LL
Correction value for
OHP upper thermistor
main set value under LL
environment
OHP upper thermistor
main set value under LL
environment
65
65
Item
Default value
62-sheet
machine
machine
70-sheet
machine
machine
AG
HL_LM OHP LL
Correction value for LL
environment OHP lower
thermistor mains et
value
environment OHP lower
thermistor mains et
value
65
65
AH
HL_US OHP LL
Correction value for
OHP upper thermistor
sub set value under LL
environment
OHP upper thermistor
sub set value under LL
environment
65
65
AI
HL_EX OHP LL
Correction value for
OHP external
thermistor set value
under LL environment
OHP external
thermistor set value
under LL environment
50
50
AJ
HL_UM
ENVELOPE LL
ENVELOPE LL
Correction value for
envelope upper
thermistor main set
value under LL
environment
envelope upper
thermistor main set
value under LL
environment
60
60
AK
HL_LM
ENVELOPE LL
ENVELOPE LL
Correction value for LL
environment envelope
lower thermistor main
set value
environment envelope
lower thermistor main
set value
50
50
AL
HL_US
ENVELOPE LL
ENVELOPE LL
Correction value for
envelope upper
thermistor sub set value
under LL environment
envelope upper
thermistor sub set value
under LL environment
50
50
AM
HL_EX
ENVELOPE LL
ENVELOPE LL
Correction value for
envelope external
thermistor set value
under LL environment
envelope external
thermistor set value
under LL environment
50
50
AN
HL_UM E-STAR
LL
LL
Correction value for
upper thermistor main
set value when
preheating under LL
environment
upper thermistor main
set value when
preheating under LL
environment
60
60
AO
HL_US E-STAR
LL
LL
Correction value for LL
environment preheating
upper thermistor sub
set value
environment preheating
upper thermistor sub
set value
60
60
AP
HL_EX E-STAR
LL
LL
Correction value for LL
environment preheating
external thermistor set
value
environment preheating
external thermistor set
value
55
55
AQ
HL_UM PRE-
JOB LL
JOB LL
Correction value for
upper thermistor main
set value when
recovering from
preheating under LL
environment
upper thermistor main
set value when
recovering from
preheating under LL
environment
65
55
AR
HL UM THIN
PAPER BW LL
PAPER BW LL
Correction value for LL
environment black and
white thin paper upper
thermistor main set
value
environment black and
white thin paper upper
thermistor main set
value
55
55
AS
HL LM THIN
PAPER BW LL
PAPER BW LL
Correction value for LL
environment black and
white thin paper lower
thermistor main set
value
environment black and
white thin paper lower
thermistor main set
value
55
55
AT
HL US THIN
PAPER BW LL
PAPER BW LL
Correction value for LL
environment black and
white thin paper upper
thermistor sub set value
environment black and
white thin paper upper
thermistor sub set value
55
55
AU
HL EX THIN
PAPER BW LL
PAPER BW LL
Correction value for LL
environment black and
white thin paper
external thermistor set
value
environment black and
white thin paper
external thermistor set
value
50
50
AV
HL UM THIN
PAPER CL LL
PAPER CL LL
Correction value for LL
environment color thin
paper upper thermistor
main set value
environment color thin
paper upper thermistor
main set value
55
55
AW
HL LM THIN
PAPER CL LL
PAPER CL LL
Correction value for LL
environment color thin
paper lower thermistor
main set value
environment color thin
paper lower thermistor
main set value
55
55
Item
Default value
62-sheet
machine
machine
70-sheet
machine
machine
MX-7001N SIMULATION 7 – 48
43-21
Purpose
Adjustment/Setting
Function (Purpose) Used to set the environment correction
under high temperature and high humidity
(H/H) for the fusing temperature setting
(SIM 43-1) in each paper mode.
(H/H) for the fusing temperature setting
(SIM 43-1) in each paper mode.
Section
Operation/Procedure
1)
1)
Select an item to be set with [
↑] and [↓] keys.
2)
Enter the adjustment value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved.
The set value in step 2 is saved.
Correction value: -49 to +49, 1 count = 1
°C change
AX
HL US THIN
PAPER CL LL
PAPER CL LL
Correction value for LL
environment color thin
paper upper thermistor
sub set value
environment color thin
paper upper thermistor
sub set value
55
55
AY
HL EX THIN
PAPER CL LL
PAPER CL LL
Correction value for LL
environment color thin
paper external
thermistor set value
environment color thin
paper external
thermistor set value
50
50
AZ
HL UM THIN
PAPER READY
LL
PAPER READY
LL
Correction value for LL
environment thin paper
ready upper thermistor
main temperature value
environment thin paper
ready upper thermistor
main temperature value
55
55
BA
HL UM REC
PAPER BW LL
PAPER BW LL
Correction value for LL
environment black and
white recycled paper
upper thermistor main
set value
environment black and
white recycled paper
upper thermistor main
set value
55
55
BB
HL LM REC
PAPER BW LL
PAPER BW LL
Correction value for LL
environment black and
white recycled paper
lower thermistor main
set value
environment black and
white recycled paper
lower thermistor main
set value
55
55
BC
HL US REC
PAPER BW LL
PAPER BW LL
Correction value for LL
environment black and
white recycled paper
upper thermistor sub
set value
environment black and
white recycled paper
upper thermistor sub
set value
55
55
BD
HL EX REC
PAPER BW LL
PAPER BW LL
Correction value for LL
environment black and
white recycled paper
external thermistor set
value
environment black and
white recycled paper
external thermistor set
value
50
50
BE
HL UM REC
PAPER CL LL
PAPER CL LL
Correction value for LL
environment color
recycled paper upper
thermistor main set
value
environment color
recycled paper upper
thermistor main set
value
55
55
BF
HL LM REC
PAPER CL LL
PAPER CL LL
Correction value for LL
environment color
recycled paper lower
thermistor main set
value
environment color
recycled paper lower
thermistor main set
value
55
55
BG
HL US REC
PAPER CL LL
PAPER CL LL
Correction value for LL
environment color
recycled paper upper
thermistor sub set value
environment color
recycled paper upper
thermistor sub set value
55
55
BH
HL EX REC
PAPER CL LL
PAPER CL LL
Correction value for LL
environment color
recycled paper external
thermistor set value
environment color
recycled paper external
thermistor set value
50
50
BI
HL UM REC
PAPER READY
LL
PAPER READY
LL
Correction value for LL
environment recycled
paper ready upper
thermistor main
temperature value
environment recycled
paper ready upper
thermistor main
temperature value
55
55
Item
Default value
62-sheet
machine
machine
70-sheet
machine
machine
Item
Default value
62-sheet
machine
machine
70-sheet
machine
machine
A
HL_UM READY
HH
HH
Correction value for
upper thermistor main
set value when ready
standby under HH
environment
upper thermistor main
set value when ready
standby under HH
environment
45
45
B
HL_LM READY
HH
HH
Correction value for HH
environment ready
standby lower
thermistor main set
value
environment ready
standby lower
thermistor main set
value
45
45
C
HL_US READY
HH
HH
Correction value for
upper thermistor sub
set value when ready
standby under HH
environment
upper thermistor sub
set value when ready
standby under HH
environment
45
45
D
HL_EX READY
HH
HH
Correction value for
external thermistor set
value when ready under
HH environment
external thermistor set
value when ready under
HH environment
40
40
E
HL_UM PLAIN
BW HH
BW HH
Correction value for
black and white plain
paper upper thermistor
main set value under
HH environment
black and white plain
paper upper thermistor
main set value under
HH environment
45
45
F
HL_LM PLAIN
BW HH
BW HH
Correction value for HH
environment black and
white plain paper lower
thermistor main set
value
environment black and
white plain paper lower
thermistor main set
value
50
50
G
HL_US PLAIN
BW HH
BW HH
Correction value for
black and white plain
paper upper thermistor
sub set value under HH
environment
black and white plain
paper upper thermistor
sub set value under HH
environment
45
45
A㧦 65
㧧
HL_UM READY LL
B㧦 65
㧧
HL_LM READY LL
C㧦 65
㧧
HL_US READY LL
D㧦 55
㧧
HL_EX READY LL DUP
A:
SIMULATION NO.43㧙20
FUSER TEMP ADJUSTMENT (LL)
65
㨇
1 㨪 99㨉
OK
TEST
CLOSE
E㧦55
㧧
HL_UM PLAIN BW LL
F㧦65
㧧
HL_LM PLAIN BW LL
G㧦50
㧧
HL_US PLAIN BW LL
H㧦55
㧧
HL_EX PLAIN BW LL
I㧦 55
㧧
HL_UM PLAIN CL LL
J㧦 60
㧧
HL_LM PLAIN CL LL
K㧦55
㧧
HL_US PLAIN CL LL
L㧦 55
㧧
HL_EX PLAIN CL LL
Click on the first or last page to see other MX-6201N / MX-7001N (serv.man19) service manuals if exist.