MX-7000N  SIMULATION  7 – 81
2)
Set item A (L4) and item B (L5) to 0. 
3)
Set the magnification ratio to 200%, and press [COLOR] and
[BW] key to make a print.
4)
Measure the printed image, and input the distance a (DSPF) to
L4 and L5 in the unit of 0.1mm.
L4: Distance a (DSPF surface: 200%) (Unit: 0.1mm)
L5: Distance a (DSPF back surface: 200%) (Unit: 0.1mm)
5)
Press [EXECUTE] key. (The set value is saved.)
 
50-10
Purpose
Adjustment
Function (Purpose) Used to adjust the print image off-center
position. (Adjustment is made separately
for each paper feed section.)
Section
Operation/Procedure
1)
Select a target item of the adjustment with [
↑] and [↓] keys on
the touch panel. 
2)
Enter the adjustment value with 10-key.
3)
Press [EXECUTE] key. (The set value is saved.)
 
50-12
Purpose
Adjustment
Function (Purpose) Used to perform the scan image off-center
position adjustment. (The adjustment is
made separately for each scan mode.)
Section
Operation/Procedure
1)
Select a target item of the adjustment with [
↑] and [↓] keys on
the touch panel. 
2)
Enter the adjustment value with 10-key.
3)
Press [OK] key. (The set value is saved.)
Item
Default 
value
A
L4
Distance of up to 10mm from 
the front surface image lead 
edge (200%, 0.1mm unit)
-
B
L5
Distance of up to 10mm from 
the back surface image lead 
edge (200%, 0.1mm unit)
-
C
LEAD_EDGE (SIDE1)
Image loss amount setting 
SIDE 1
20
D
FRONT_REAR (SIDE1)
20
E
TRAIL_EDGE (SIDE1)
30
F
LEAD_EDGE (SIDE2)
Image loss amount setting 
SIDE 2
30
G
FRONT_REAR (SIDE2)
20
H
TRAIL_EDGE (SIDE2)
20
[DSPF front surface]
[DSPF back surface]
Distance a
Distance a
A : 0
;
L4
B : 0
;
L5
C : 20
;
LEAD_EDGE (SIDE1)
D : 20
;
FRONT_REAR (SIDE1)
A:
SIMULATION NO.50-07
LEAD EDGE ADJUSTMENT (SPF CALC.).
0
0
999
TEST
E : 30
;
TRAIL_EDGE (SIDE1)
F : 30
;
LEAD_EDGE (SIDE2)
G : 20
;
FRONT_REAR (SIDE2)
H : 20
;
TRAIL_EDGE (SIDE2)
EXECUTE
CLOSE
Item
Default 
value
A
BK-MAG
Main scan print magnification ratio BK
100
B
MFT
Print off-center adjustment value 
(manual feed)
50
C
CS1
Print off-center adjustment value 
(Cassette 1)
50
D
CS2
Print off-center adjustment value 
(Cassette 2)
50
E
CS3
Print off-center adjustment value 
(Cassette 3)
50
F
CS4
Print off-center adjustment value 
(Cassette 4)
50
G
LCC
Print off-center adjustment value (LCC)
50
H
ADU
Print off-center adjustment value 
(ADU)
50
I
MULTI COUNT
Print quantity 
1
J
PAPER
MFT
Cassette 
selection
1: Manual feed
2
CS1
2: Cassette 1
CS2
3: Cassette 2
CS3
4: Cassette 3
CS4
5: Cassette 4
LCC
6: LCC
K
DUPLEX
YES
Duplex print 
select
0: Select
1
NO
1: Not selected
Item
Default 
value
A
OC
OC document off-center adjustment
50
B
SPF (SIDE1)
DSPF front surface document off-center 
adjustment
50
C
SPF (SIDE2)
DSPF back surface document off-center 
adjustment
50
A : 100
;
BK-MAG
B : 50
;
MFT
C : 50
;
CS1
D : 50
;
CS2
A:
SIMULATION NO.50-10
PAPER CENTER OFFSET SETUP
100
60
140
OK
TEST
CLOSE
E : 50
;
CS3
F : 50
;
CS4
G : 50
;
LCC
H : 50
;
ADU
I :
1
;
MULTICOUNT
J :
2
;
PAPER : CS1
K :
1
;
DUPLEX : NO
EXECUTE
MX-7000N  SIMULATION  7 – 82
 
50-20
Purpose
Adjustment
Function (Purpose) Used to perform the main scanning direc-
tion manual registration adjustment.
Section
Operation/Procedure
1)
Select a target item of the adjustment with [
↑] and [↓] keys on
the touch panel. 
2)
Enter the adjustment value with 10-key.
3)
Press [EXECUTE] key. (The set value is saved.)
 
50-21
Purpose
Adjustment
Function (Purpose) Used to perform the sub scanning direction
manual registration adjustment. 
Section
Operation/Procedure
1)
Select a target item of the adjustment with [
↑] and [↓] keys on
the touch panel. 
2)
Enter the adjustment value with 10-key.
3)
Press [EXECUTE] key. (The set value is saved.)
 
50-22
Purpose
Adjustment
Function (Purpose) Used to perform the main/sub scanning
auto registration adjustment. 
Section
Operation/Procedure
1)
Select a target item for the adjustment with [REGIST], [DRUM
POS], and [ALL] keys on the touch panel.
2)
Press [EXECUTE] key.
All the drum motors are operated to start the adjustment.
Item
Default 
value
A CYAN (FRONT)
Registration adjustment value main 
scanning direction F side (Cyan)
100
B CYAN (REAR)
Registration adjustment value main 
scanning direction R side (Cyan)
100
C MAGENTA 
(FRONT)
Registration adjustment value main 
scanning direction F side (Magenta)
100
D MAGENTA (REAR)
Registration adjustment value main 
scanning direction R side Magenta)
100
E YELLOW (FRONT)
Registration adjustment value main 
scanning direction F side (Yellow)
100
F YELLOW (REAR)
Registration adjustment value main 
scanning direction R side (Yellow)
100
G MULTICOUNT
Print quantity 
1
H PAPER
MFT
Cassette 
selection
1: Manual feed
4
CS1
2: Cassette 1
CS2
3: Cassette 2
CS3
4: Cassette 3
CS4
5: Cassette 4
LCC
6: LCC
I
DUPLEX
YES
Duplex print 
select
0: Select
1
NO
1: Not selected
A : 50
;
OC
B : 50
;
SPF(SIDE1)
C : 50
;
SPF(SIDE2)
A:
SIMULATION NO.50-12
ORIGINAL CENTER OFFSET SETUP
50
1
99
OK
TEST
CLOSE
A : 100
;
CYAN(FRONT)
B : 100
;
CYAN(REAR)
C : 100
;
MAGENTA(FRONT)
D : 100
;
MAGENTA(REAR)
A:
SIMULATION NO.50-20
REGISTRATION ADJUSTMENT : FRONT-REAR DIRECTION
100
1
199
OK
TEST
CLOSE
E : 100
;
YELLOW(FRONT)
F : 100
;
YELLOW(REAR)
G :
1
;
MULTICOUNT
H :
4
;
PAPER : CS3
I :
1
;
DUPLEX : NO
EXECUTE
Item
Default 
value
A
CYAN
Registration adjustment value sub 
scanning direction CYAN
100
B
MAGENTA
Registration adjustment value sub 
scanning direction MAGENTA
100
C
YELLOW
Registration adjustment value sub 
scanning direction YELLOW
100
D
MULTICOUNT
Print quantity 
1
E
PAPER
MFT
Cassette 
selection
Manual feed
2
CS1
Cassette 1
CS2
Cassette 2
CS3
Cassette 3
CS4
Cassette 4
LCC
LCC
F
DUPLEX
YES
Duplex print 
select
Select
1
NO
Not select
A : 100
;
CYAN
B : 100
;
MAGENTA
C : 100
;
YELLOW
D :
1
;
MULTICOUNT
A:
SIMULATION NO.50-21
REGISTRATION ADJUSTMENT : SCANNING DIRECTION
100
1
199
OK
TEST
CLOSE
E :
2
;
PAPER : CS1
F :
1
;
DUPLEX : NO
EXECUTE
MX-7000N  SIMULATION  7 – 83
<Error display for abnormal completion>
Item
Default 
value
ALL (Auto 
registration 
adjustment, 
auto phase 
adjustment)
REGIST (Auto 
registration 
adjustment 
execution)
MAIN F
C
Registration adjustment value main scanning direction (Cyan F side)
100
M
Registration adjustment value main scanning direction (Magenta F side)
100
Y
Registration adjustment value main scanning direction (Yellow F side)
100
MAIN R
C
Registration adjustment value main scanning direction (Cyan R side)
100
M
Registration adjustment value main scanning direction (Magenta R side)
100
Y
Registration adjustment value main scanning direction (Yellow R side)
100
SUB
C
Registration adjustment value sub scanning direction (Cyan drum 
→ Black drum)
100
M
Registration adjustment value sub scanning direction (Magenta drum 
→ Cyan drum)
100
Y
Registration adjustment value sub scanning direction (Yellow drum 
→ Magenta drum)
100
DRUM POS (Auto 
phase adjustment 
execution)
START 
POINT
K
Pulse modulation start timing
Changes up to 355
° in the increment of 5°.
0 - 71
0: 0
°
0
1: 5
°
:
:
70: 350
°
71: 355
°
CL
Pulse modulation start timing
Changes up to 355
° in the increment of 5°.
0 - 71
0: 0
°
0
1: 5
°
:
:
70: 350
°
71: 355
°
AMP
K
Pulse modulation deflection amount
0
CL
Pulse modulation deflection amount (C/M/Y average value of linearity deflection 
amount)
0
PHASE
C
Phase adjustment C 
→ Y
Changes up to 355
° in the increment of 5°.
0 - 71
0: 0
°
0
1: 5
°
:
:
70: 350
°
71: 355
°
M
Phase adjustment M 
→ Y
Changes up to 355
° in the increment of 5°.
0 - 71
0: 0
°
0
1: 5
°
:
:
70: 350
°
71: 355
°
AMP
C
Linearity deflection amount
0
M
Linearity deflection amount
0
Y
Linearity deflection amount
0
Error 
code
Error display
Error content
Compulsory 
end error
SUSPENDED
Door open during operation
SUSPENDED
CA button push during 
operation
Unconfirmed operation during 
operation (power OFF)
Basic error
1
TONNER 
EMPTY 01
BK or all color toner EMPTY 
detection 
2
BEFORE 
BEHAVIOR 02
Other conditions
4
SENSOR 
CALIBRATION 
04
After 3-time retries of F or R, 
the target is  not reached. 
5
TIME OVER 05
Data is not acquired for 90sec 
from the latest data 
acquisition. 
7
PROCESS 
CONTROL 07
Process control error detection
Sub 
scanning 
adjustment 
error
10
SUB BLACK 
FRONT 10
The pitch data number is not 
the specified number. 
11
SUB BLACK 
FRONT 11
The pitch data is not in the 
specified allowable range. 
15
SUB BLACK 
REAR 15
The pitch data number is not in 
the specified allowable range.
16
SUB BLACK 
REAR 16
The pitch data is not in the 
specified allowable range. 
20
SUB CYAN 
FRONT 20
The pitch data number is not 
the specified number. 
21
SUB CYAN 
FRONT 21
The pitch data is not in the 
specified allowable range. 
Sub 
scanning 
adjustment 
error
22
SUB CYAN 
FRONT 22
The calculation result value is 
not in the specified allowable 
range. 
23
SUB CYAN 
FRONT 23
The amount of change in the 
calculation result value is not 
in the specified allowable 
range. 
25
SUB CYAN 
REAR 25
The pitch data number is not 
the specified number. 
26
SUB CYAN 
REAR 26
The pitch data is not in the 
specified allowable range. 
27
SUB CYAN 
REAR 27
The calculation result value is 
not in the specified allowable 
range. 
28
SUB CYAN 
REAR 28
The amount of change in the 
calculation result value is not 
in the specified allowable 
range. 
30
SUB MAGENTA 
FRONT 30
The pitch data number is not 
the specified number. 
31
SUB MAGENTA 
FRONT 31
The pitch data is not in the 
specified allowable range. 
32
SUB MAGENTA 
FRONT 32
The calculation result value is 
not in the specified allowable 
range. 
33
SUB MAGENTA 
FRONT 33
The amount of change in the 
calculation result value is not 
in the specified allowable 
range. 
Error 
code
Error display
Error content
MX-7000N  SIMULATION  7 – 84
Sub 
scanning 
adjustment 
error
35
SUB MAGENTA 
REAR 35
The pitch data number is not 
the specified number. 
36
SUB MAGENTA 
REAR 36
The pitch data is not in the 
specified allowable range. 
37
SUB MAGENTA 
REAR 37
The calculation result value is 
not in the specified allowable 
range. 
38
SUB MAGENTA 
REAR 38
The amount of change in the 
calculation result value is not 
in the specified allowable 
range. 
40
SUB YELLOW 
FRONT 40
The pitch data number is not 
the specified number. 
41
SUB YELLOW 
FRONT 41
The pitch data is not in the 
specified allowable range. 
42
SUB YELLOW 
FRONT 42
The calculation result value is 
not in the specified allowable 
range. 
43
SUB YELLOW 
FRONT 43
The amount of change in the 
calculation result value is not 
in the specified allowable 
range. 
45
SUB YELLOW 
REAR 45
The pitch data number is not 
the specified number. 
46
SUB YELLOW 
REAR 46
The pitch data is not in the 
specified allowable range. 
47
SUB YELLOW 
REAR 47
The calculation result value is 
not in the specified allowable 
range. 
Main 
scanning 
adjustment 
error
48
SUB YELLOW 
REAR 48
The amount of change in the 
calculation result value is not 
in the specified allowable 
range. 
50
MAIN BLACK 
FRONT 50
The pitch data number is not 
the specified number. 
51
MAIN BLACK 
FRONT 51
The pitch data is not in the 
specified allowable range. 
55
MAIN BLACK 
REAR 55
The pitch data number is not in 
the specified allowable range. 
56
MAIN BLACK 
REAR 56
The pitch data is not in the 
specified allowable range. 
60
MAIN CYAN 
FRONT 60
The pitch data number is not 
the specified number. 
61
MAIN CYAN 
FRONT 61
The pitch data is not in the 
specified allowable range. 
62
MAIN CYAN 
FRONT 62
The calculation result value is 
not in the specified allowable 
range. 
63
MAIN CYAN 
FRONT 63
The amount of change in the 
calculation result value is not 
in the specified allowable 
range. 
65
MAIN CYAN 
REAR 65
The pitch data number is not 
the specified number. 
66
MAIN CYAN 
REAR 66
The pitch data is not in the 
specified allowable range. 
67
MAIN CYAN 
REAR 67
The calculation result value is 
not in the specified allowable 
range. 
68
MAIN CYAN 
REAR 68
The amount of change in the 
calculation result value is not 
in the specified allowable 
range. 
70
MAIN MAGENTA 
FRONT 70
The pitch data number is not 
the specified number. 
71
MAIN MAGENTA 
FRONT 71
The pitch data is not in the 
specified allowable range. 
72
MAIN MAGENTA 
FRONT 72
The calculation result value is 
not in the specified allowable 
range. 
73
MAIN MAGENTA 
FRONT 73
The amount of change in the 
calculation result value is not 
in the specified allowable 
range. 
Error 
code
Error display
Error content
Main 
scanning 
adjustment 
error
75
MAIN MAGENTA 
REAR 75
The pitch data number is not 
the specified number. 
76
MAIN MAGENTA 
REAR 76
The pitch data is not in the 
specified allowable range. 
77
MAIN MAGENTA 
REAR 77
The calculation result value is 
not in the specified allowable 
range. 
78
MAIN MAGENTA 
REAR 78
The amount of change in the 
calculation result value is not 
in the specified allowable 
range. 
80
MAIN YELLOW 
FRONT 80
The pitch data number is not 
the specified number. 
81
MAIN YELLOW 
FRONT 81
The pitch data is not in the 
specified allowable range. 
82
MAIN YELLOW 
FRONT 82
The calculation result value is 
not in the specified allowable 
range. 
83
MAIN YELLOW 
FRONT 83
The amount of change in the 
calculation result value is not 
in the specified allowable 
range. 
85
MAIN YELLOW 
REAR 85
The pitch data number is not 
the specified number. 
86
MAIN YELLOW 
REAR 86
The pitch data is not in the 
specified allowable range. 
87
MAIN YELLOW 
REAR 87
The calculation result value is 
not in the specified allowable 
range. 
88
MAIN YELLOW 
REAR 88
The amount of change in the 
calculation result value is not 
in the specified allowable 
range. 
91
RIB BLACK 91
The rib cannot be detected 
either in the phase pattern or 
in the sub pattern. 
92
RIB CYAN 92
The rib cannot be detected 
either in the phase pattern or 
in the sub pattern. 
93
RIB MAGENTA 
93
The rib cannot be detected 
either in the phase pattern or 
in the sub pattern. 
94
RIB YELLOW 94
The rib cannot be detected 
either in the phase pattern or 
in the sub pattern. 
Other errors
99
OTHER 99
Other errors
Phase 
adjustment 
error
110
PHASE BLACK 
FRONT 110
Phase number error
111
PHASE BLACK 
FRONT 111
Phase pitch error
115
PHASE BLACK 
REAR 115
Phase number error
116
PHASE BLACK 
REAR 116
Phase pitch error
120
PHASE CYAN 
FRONT 120
Phase number error
121
PHASE CYAN 
FRONT 121
Phase pitch error
125
PHASE CYAN 
REAR 125
Phase number error
126
PHASE CYAN 
REAR 126
Phase pitch error
130
PHASE 
MAGENTA 
FRONT 130
Phase number error
131
PHASE 
MAGENTA 
FRONT131
Phase pitch error
135
PHASE 
MAGENTA 
REAR 135
Phase number error
136
PHASE 
MAGENTA 
REAR 136
Phase pitch error
Error 