Sharp MX-2640N / MX-2640NR / MX-2640FN / MX-3140N / MX-3140NR / MX-3140FN / MX-3640N / MX-3640NR / MX-3640FN (serv.man36) Service Manual ▷ View online

MX-3640N  ADJUSTMENTS AND SETTINGS  5 – 78
 
16-C
Scan image magnification ratio adjustment 
(main scanning direction) 
(Manual adjustment) (RSPF mode)
This adjustment must be performed in the following cases:
* When the scan control PWB is replaced.
* When the EEPROM on the scan control PWB is replaced.
* When U2 trouble occurs.
* When  the  copy  magnification  ratio  of the   RSPF mo de  copy
image in the main scanning direction is not proper.
* When the RSPF is disassembled.
a. Adjustment procedures
1) Place the duplex adjust ment chart shown below on the docu-
ment tray of the RSPF.
The adjustment chart is prepared by the following procedures.
Use A4 (11" x 8.5") paper, and put ma rks on both sides and
both surfaces of the paper at 10mm from each edge.
2) Make a duplex copy at the normal ratio on A4 paper.
3) Measure  the  images  on the co py  paper  and the original
images.
4) Obtain the image magnification ratio according to the following
formula:
Image magnification ratio = Original size / Original size x 100
(%)
Image magnification ratio = 99 / 100 x 100 = 99 (%)
If  the  image  magnification ratio is  within  the  specified  range
(100  0.8%), there is no need to perform the adjustment.
If it is not within the specified range, perform the following pro-
cedures.
5) Enter the SIM 48-1 mode.
RSPF
6) Select an adjustment item  of SPF (MAIN)/SPFB (MAIN) with
the scroll key.
7) Enter an adjustment value with 10-key, and press [OK] key.
When the adjustment value is increased, the image magnifica-
tion ratio is increased. When the adjustment value is changed
by 1, the image magnification ratio is changed by 0.02%.
8) Make a normal copy and obtain the copy magnification ratio.
Repeat  the  procedures  of 1)   -  8) until a satisfactor y  result is
obtained.
 
16-D
Scan image magnification ratio adjustment 
(sub scanning direction) (Manual 
adjustment) (RSPF mode)
This adjustment must be performed in the following cases:
* When the SCAN CONTROL PWB is replaced.
* When the EEPROM on the SCAN CONTROL PWB is replaced.
* When U2 trouble occurs.
* When  the  copy magnification ra tio  of  the R SPF  mode copy
image in the sub scanning direction is not proper.
* When the RSPF is disassembled.
1) Place the duplex adjustment chart shown below on the docu -
ment tray of the RSPF.
The adjustment chart is prepared by the following procedures.
Use A4 (11" x 8.5") paper, and put marks on both  sides and
both surfaces of the paper at 10mm from each edge.
A4 size
(Both the front surface
and the back surface)
10mm
10mm
Paper pass direction
original
10
50
100
150
200
250
copy
10
50
100
150
200
250
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
0$*1,),&$7,21$'-8670(17
˷̚˹
˖&&'0$,1
˖&&'68%
˖63)0$,1
˖63)68%
˖63)%0$,1
˖63)%68%
2.
Item
Display
Content
Setting 
range
Default 
value
A
CCD(MAIN)
SCAN main scanning 
magnification ratio 
adjustment (CCD)
1 - 99
50
B
CCD(SUB)
SCAN sub scanning 
magnification ratio 
adjustment (CCD)
1 - 99
50
C
SPF(MAIN)
RSPF document front 
surface magnification ratio 
adjustment (Main scan)
1 - 99
50
D
SPF(SUB)
RSPF document front 
surface magnification ratio 
adjustment (Sub scan)
1 - 99
50
E
SPFB(MAIN)
RSPF document back 
surface magnification ratio 
adjustment (Main scan)
1 - 99
50
F
SPFB(SUB)
RSPF document back 
surface magnification ratio 
adjustment (Sub scan)
1 - 99
50
SPF (MAIN)
Main scanning direction image magnification ratio 
(Front surface)
SPFB (MAIN) Main scanning direction image magnification ratio 
(Back surface)
A4 size
10mm
10mm
Paper pass direction
MX-3640N  ADJUSTMENTS AND SETTINGS  5 – 79
2) Make a duplex copy at the normal ratio on A4 paper.
3) Measure  the  images  on the co py  paper  and the original
images.
4) Obtain the image magnification ratio according to the following
formula:
Image magnification ratio = Original size / Original size x 100
(%)
Image magnification ratio = 99 / 100 x 100 = 99 (%)
If  the  image  magnification ratio is  within  the  specified  range
(100  0.8%), there is no need to perform the adjustment.
If it is not within the specified range, perform the following pro-
cedures.
5) Enter the SIM 48-1 mode.
6) Select an adjustment item with the scroll key.
7) Enter an image magnification ratio  adjustment value with  10-
key, and press [OK] key.
When the adjustment value is increased, the image magnifica-
tion ratio is increased.
When the adjustment value is changed by 1, the image magni-
fication ratio is changed by 0.1%.
8) Make a normal copy and obtain the copy magnification ratio.
Repeat  the  procedures  of 1)   -  8) until a satisfactor y  result is
obtained.
 
ADJ 17
Scan image off-center 
adjustment 
(Manual adjustment)
Normally if the adjustment is executed by ADJ 4 (automatic adjust-
ment), there is no need to execute this adjustment.
Only when the manual adjustment is required, execute this adjust-
ment.
In other words, this manual ad justment is executed when a satis-
factory result is not  obtained from the automatic adjustment (ADJ
4).
 
17-A
Scan image off-center adjustment (Manual 
adjustment) (Document table mode)
This adjustment must be performed in the following cases:
* When the scanner (reading) section is disassembled.
* When the scanner (reading) unit is replaced.
* When a U2 trouble occurs.
* When the scanner control PWB is replaced.
* When the EEPROM on the scanner control PWB is replaced.
1) Make a copy of the adjustment chart (made by yourself) in the
adjustment mode (document table).
2) Check the copy image center position.
If A - B =  1.0mm, the adjustment is not required.
If  the  above  condition  is  not  satisfied, p erform  the  following
procedures.
Item
Display
Content
Setting 
range
Default 
value
A
CCD(MAIN)
SCAN main scanning 
magnification ratio 
adjustment (CCD)
1 - 99
50
B
CCD(SUB)
SCAN sub scanning 
magnification ratio 
adjustment (CCD)
1 - 99
50
C
SPF(MAIN)
RSPF document front 
surface magnification ratio 
adjustment (Main scan)
1 - 99
50
D
SPF(SUB)
RSPF document front 
surface magnification ratio 
adjustment (Sub scan)
1 - 99
50
E
SPFB(MAIN)
RSPF document back 
surface magnification ratio 
adjustment (Main scan)
1 - 99
50
F
SPFB(SUB)
RSPF document back 
surface magnification ratio 
adjustment (Sub scan)
1 - 99
50
SPF (SUB)
Sub scanning direction image magnification ratio 
(Front surface)
SPFB (SUB)
Sub scanning direction image magnification ratio 
(Back surface)
original
copy
10
50
100
150
200
10
50
100
150
200
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
0$*1,),&$7,21$'-8670(17
˷̚˹
˖&&'0$,1
˖&&'68%
˖63)0$,1
˖63)68%
˖63)%0$,1
˖63)%68%
2.
B
A = B
A
B'
A' - B' =
1.0mm
A'
(100%)
MX-3640N  ADJUSTMENTS AND SETTINGS  5 – 80
3) Enter the SIM 50-12 mode.
4) Select the adjustment mode OC with the scroll key.
5) Enter the adjustment value with 10-key, and press [OK] key.
The entered value is set.
When the set value is increased, the main scanning print posi-
tion is shifted to the front side by 0.1mm.
6) Go to the copy mode, and make a copy.
Repeat the procedures of 1) - 6) until the above condition is satis-
fied.
 
17-B
Scan image off-center adjustment 
(Manual adjustment) (RSPF mode)
This adjustment must be performed in the following cases:
* When the scan control PWB is replaced.
* When the EEPROM on the scan control PWB is replaced.
* When the scanner (reading) section is disassembled.
* When the scanner (reading) section is replaced.
* When U2 trouble occurs.
* When the RSPF section is disassembled.
* When the RSPF unit is replaced.
To execute this adjustment,  it is required that the ADJ 17A Scan
image  off-center  adjustment  (Document t able  mode)  must have
been properly adjusted.
1) Prepare the adjustment chart.
Draw a line at the center of the front surface and the back sur-
face of A4 (11" x 8.5") paper in parallel with the paper transport
direction.
2) Set the adjustment chart to the RSPF.
3) Make a duplex copy in the normal magnification ratio from the
manual paper feed tray, and check the image position on the
front surface and the back surface of the copy paper.
If the difference is within the range of 0  2.7mmm there is no
need to perform the adjustment.
If the adjustment is required, perform the following procedures.
4) Enter the SIM 50-12 or 50-6 mode.
SIM50-12
A  -  C: When the adjustment value is increased, the image
position is shifted to the rear frame side.
1step = 0.1mm
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
25,*,1$/&(17(52))6(76(783
˷̚˹
˖2&
˖63)6,'(
˖63)6,'(
2.
Paper transport direction
Front surface
Back surface
Draw a line at the center of the
front surface and the back surface
of paper in parallel with the paper
transport direction.
Item
Display
Content
Setting 
range
Default 
value
A
OC
Document table image off-
center adjustment
1 - 99
50
B
SPF(SIDE1)
SPF front surface image off-
center adjustment
1 - 99
50
C
SPF(SIDE2)
SPF back surface image off-
center adjustment
1 - 99
50
original
copy
a
b
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
25,*,1$/&(17(52))6(76(783
˷̚˹
˖2&
˖63)6,'(
˖63)6,'(
2.
(SIM50-12)
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
/($'('*($'-8670(179$/8(63)
˷̚˹
˖6,'(
˖6,'(
˖/($'B('*(6,'(
˖)5217B5($56,'(
˖/($'B('*(6,'(
˖75$,/B('*(6,'(
˖)5217B5($56,'(
˖75$,/B('*(6,'(
˖2))6(7B63)
˖2))6(7B63)
˖6&$1B63(('B63)
2.
(SIM50-6)
MX-3640N  ADJUSTMENTS AND SETTINGS  5 – 81
SIM50-6
* Item A, B: When the adjustment value is increased, the scan
timing is delayed.
* Item  C  -  H:  When  the  adjustment  value  is  increased,  the
image loss is increased.
* Item A - H: 1 step = 0.1mm change
* The  SPF r ear  edge  image  loss setting is provided for
countermeasures  against  the ca se  when  shades  are
produced.
5) Select an adjustment mode with the scroll key.
(SIM50-12)
(SIM50-6)
6) Enter an adjustment value with 10-key, and press [OK] key.
(Change for change in the adjustment value: 0.1mm/step)
(When  the a djustment  value  is in creased,  the  print  image is
shifted to the rear.)
Repeat  the pr ocedures  of 2) - 6)   until  a sat isfactory  result is
obtained.
 
ADJ 18
Copy image position and image 
loss adjustment 
(Manual adjustment)
Normally if the adjustment is executed by ADJ 4 (automatic adjust-
ment), there is no need to execute this adjustment.
Only when the manual adjustment is required, execute this adjust-
ment.
In other words, this manual ad justment is executed when a satis-
factory result is not  obtained from the automatic adjustment (ADJ
4).
 
18-A
Copy image position, image loss, and void 
area adjustment (Manual adjustment) 
(Document table mode)
This adjustment must be performed in the following cases:
* When the scanner (reading) section is disassembled.
* When the scanner (reading) unit is replaced.
* When the LSU is replaced or removed.
* When the registration roller section is disassembled.
* U2 trouble has occurred.
* The PCU PWB has been replaced.
* The EEPROM of the PCU PWB has been replaced.
* The scanner control PWB has been replaced.
* The EEPROM on the scanner control PWB has been replaced.
Before executing this  adjustment, be sure to confirm th at the ADJ
4/ADJ 5 Print engine image skew, image position, image magnifica-
tion ratio, void area adjustments has been completed normally.
1) Place  a sca le  on  the document t able  as  shown  in  the  figure
below.
Place a scale so that it is in parallel with the scanning direction
and that its lead edge  is in contact with the document guide
plate.
Place white paper on the document table so that the scale lead
edge can be seen.
Item/Display
Content
Setting 
range
Default 
value
A SIDE1
Front surface 
document scan 
position adjustment 
(CCD)
1 - 99
50
B SIDE2
Back surface 
document scan 
position adjustment 
(CCD)
1 - 99
50
C Image 
loss 
amount 
setting 
SIDE1
LEAD_EDGE 
(SIDE1)
Front surface lead 
edge image loss 
amount setting
0 - 99
20
D
FRONT_REAR 
(SIDE1)
Front surface side 
image loss amount 
setting
0 - 99
20
E
TRAIL_EDGE 
(SIDE1)
Front surface rear 
edge image loss 
amount setting
0 - 99
40
F
Image 
loss 
amount 
setting 
SIDE2
LEAD_EDGE 
(SIDE2)
Back surface lead 
edge image loss 
amount setting
0 - 99
20
G
FRONT_REAR 
(SIDE2)
Back surface side 
image loss amount 
setting
0 - 99
20
H
TRAIL_EDGE 
(SIDE2)
Back surface rear 
edge image loss 
amount setting
0 - 99
40
I
OFFSET_SPF1
RSPF front surface 
document off-center 
adjustment
1 - 99
50
J
OFFSET_SPF2
RSPF back surface 
document off-center 
adjustment
1 - 99
50
K SCAN_SPEED_SPF1
RSPF document 
front surface 
magnification ratio 
adjustment (Sub 
scan)
1 - 99
50
L
SCAN_SPEED_SPF2
RSPF document 
back surface 
magnification ratio 
adjustment (Sub 
scan)
1 - 99
50
SPF(SIDE1)
Front surface mode
SPF(SIDE2)
Back surface mode
OFFSET SPF1
Front surface mode
OFFSET SPF2
Back surface mode
Page of 127
Display

Click on the first or last page to see other MX-2640N / MX-2640NR / MX-2640FN / MX-3140N / MX-3140NR / MX-3140FN / MX-3640N / MX-3640NR / MX-3640FN (serv.man36) service manuals if exist.