Sharp MX-2600N / MX-3100N / MX-2600G / MX-3100G (serv.man3) Handy Guide ▷ View online
25
Document Solutions After Sales Service
Firmware Upgrade
5. Select the required firmware that requires updating (example shown ICU Main & Language).
Press Execute & Yes to commence the update.
Note: If all firmware (including peripherals) require updating, select ALL.
6. During the firmware update, a progress “gauge” will be displayed.
7. Once the firmware update has completed successfully, press OK to reboot the device.
Firmware update is complete
26
Document Solutions After Sales Service
Firmware Upgrade
Network (Web Page)
1. Open a web browser and enter the following URL :‐
http://ipaddress/service_login.html or
http://ipaddress/service_account.html
http://ipaddress/service_account.html
Example:
http://192.168.0.1/service_login.html
2. To access the Service Webpage, enter the “Service” Username and Password.
Click Login:‐
Default Username:
service
Password:
service
Note: If User Authentication is enabled, open the device webpage and login by selecting “Service”
from the drop down menu and entering the service password:‐
3. When the service webpage opens, click Update of Firmware.
4. Click Browse to navigate to the location of the updated firmware file and select
Open.
27
Document Solutions After Sales Service
Firmware Upgrade
5. Press Execute to start the firmware update.
Note: Once the machine has entered “service download mode”, the update will
Commence and the progress be displayed
6. When the firmware upgrade is complete, click Reboot to execute a remote restart
Of the machine
Firmware Upgrade is complete
MX-7000N
MX-7000N
28
Document Solutions After Sales Service
Firmware Recovery Procedure
2.
Using a PC, copy the firmware file onto the root directory of the USB Memory Stick
In the event of a power failure during a firmware update or HDD failure, the machine may fail to reboot
because of corrupted firmware. To re‐install the firmware, it is necessary to boot the machine using a USB
Memory Stick
Firmware Recovery Procedure:
1.
Power off the Machine
3.
Rename the firmware file to
emupdate_P2.sfu
Example shown: 0100P20 firmware.sfu renamed to emupdate.sfu
4.
Insert the USB memory device into the machine and Power On
The machine will
BOOT
via the USB memory device. The firmware installs automatically from
the detected USB Memory Stick
5.
Once the firmware update has been installed successfully, power off the machine and remove
the USB Memory Stick
the USB Memory Stick
Emergency Firmware Recovery Complete
Note:
Always rename the firmware to the original SFU name i.e. 0100P20 firmware.sfu