[2] Consumable parts 
 
 
 
  2-2 
 
 
 
 
(4) Opened condition (Inside the machine) 
Machine installation condition 
Warranty period: 12 months 
 
3. Production control number  (lot No.) identification 
 
 
 
 
 
 
<Print Cartridge> 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
   
9  10  11  12  13  14  15  16  17  18  19 
   
◇  ▲  ▲  □  □  □  □  □  □  ○  ○  ○  ○  ◎  ◎  ◎  ◎  ◎  ◎ 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
◇:Color code     K:Back / C:Cyan / M:Magenta / Y:Yellow 
 
 
 
▲:Life           **  :  *.*k   
 
 
 
 
 
 
 
 
 
 
 
 
□:Model Code   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
○:Production date   (YYMM) 
 
 
 
 
 
 
 
 
 
 
 
 
◎:Serial number  (Product serial number per month)   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
[3] Installation 
 
 
 
 
  3-1 
 
 
 
[3] Installation Requirements 
1. Installation Requirements 
1-1. Environment 
 
1.  Temperature Range: 10°C to 32°C (50°F to 89.6°F) 
2.  Humidity Range: 15% to 80% RH 
3.  Ambient Illumination: Less than 2,000 lux (do not expose to direct sunlight) 
4.  Ventilation: 3 times/hr/person 
5.  Do not put the machine in areas that get sudden temperature changes. This includes:   
  Areas directly exposed to cool air from an air conditioner 
  Areas directly exposed to heat from a heater. 
6.  Do not put the machine in areas that get exposed to corrosive gas. 
7.  Do not install the machine at locations over 2,000 m (6,560 ft.) above sea level. 
8.  Put the machine on a strong, level base. (Inclination on any side must be no more than 
5 mm.) 
9.  Do not put the machine in areas with strong vibrations. 
[3] Installation 
 
 
 
 
  3-2 
 
 
 
1-2. Machine level 
Front to back: Within 5 mm (0.2") of level 
Right to left: Within 5 mm (0.2") of level 
1-3. Machine Space Requirement 
Put the machine near the power source with these clearances: 
DX-C200P 
 
Left side: Over 20 cm (7.9") 
Rear: Over 10 cm (4") 
Right side: Over 10 cm (4") 
Front: Over 70 cm (27.5") 
[3] Installation 
 
 
 
 
  3-3 
 
 
 
DX-C200 
 
Left side: Over 20 cm (7.9") 
Rear: Over 20 cm (7.9") 
Right side: Over 10 cm (4") 
Front: Over 70 cm (27.5") 
Top: Over 24 cm (9.5") 
Power Requirements 
 
  Make sure that the plug is tightly in the outlet. 
  Avoid multi-wiring. 
  Make sure that you ground the machine. 
 
Input voltage level 
120 V, 60 Hz: More than 11 A (for North America) 
220 V to 240 V, 50 Hz/60 Hz: More than 6 A (for Europe/ Asia) 
Permitted voltage fluctuation: 10% 
Do not set anything on the power cord. 
 