DOWNLOAD Sharp DX-B350P / DX-B450P / DX-CSX1 / DX-CSX2 / TEX1 / DX-UX1 / DX-UX4 Service Manual ↓ Size: 5.63 MB | Pages: 127 in PDF or view online for FREE

Model
DX-B350P DX-B450P DX-CSX1 DX-CSX2 TEX1 DX-UX1 DX-UX4
Pages
127
Size
5.63 MB
Type
PDF
Document
User Manual / Operation Manual
Brand
Device
Copying Equipment / User Guide
File
dx-b350p-dx-b450p-dx-csx1-dx-csx2-tex1-dx-ux1-dx-u.pdf
Date

Sharp DX-B350P / DX-B450P / DX-CSX1 / DX-CSX2 / TEX1 / DX-UX1 / DX-UX4 User Manual / Operation Manual ▷ View online

User’s Guide
3-11
Operator Panel Menus
Operator Panel
     Network Address
<hex display 
of MAC 
address>
NA
Displays MAC address of network interface.
     IP Address
data entry
000.000.000.000
IP Address. If DHCP is enabled, this is 
read-only. Otherwise, this can be changed by 
the address can be set manually here
     Subnet Mask
data entry
000.000.000.000
     Default Gateway
data entry
000.000.000.000
     LPD Banner
On/Off
Off
If ON, prints a special “banner page” before 
each LPR print job.
     DHCP
On/Off
On
     IPv6
On/Off
Off
     Delay Out Close
On/Off
Off
When ON, the printer will wait until the job 
is completely printed and delivered to the 
output tray before terminating the 
connection, allowing all reverse-channel 
data to be sent back to the host. This will 
cause a reduction in printer throughput.
When OFF, reverse-channel data generated 
after the job interpretation is discarded. No 
reduction in printer throughput occurs.
     mDNS
On/Off
On
Enabled multicast-DNS protocol. mDNS is 
the underlying protocol for “Bonjour”.
     Local Link
read-only
000.000.000.000
Auto-negotiated “local link” internet address 
(used primarily by Bonjour protocol)
     Multi-Session
On/Off
Off
When On, allows the printer to have 
multiple network print sessions open at a 
time. When Off, only 1 session can be 
opened at a time. Some server environments 
may benefit from a setting of Off.
     EtherTalk
On/Off
On
     Netware Setup
This submenu allows you to set up the 
Netware interface. 
             Netware
On/Off
Off
             Netware Frame
Auto-Sense, 
802.3, 
Ethernet II, 
802.2 SNAP, 
802.2
Auto-Sense
             Netware Mode
NPRINTER
PSERVER
PSERVER
Menu Item
Value 
Default
Description
3-12
User’s Guide
Operator Panel Menus
Operator Panel
     Binary PS
On/Off
On
When On, the feature allows all binary codes 
to be processed by the PostScript interpreter. 
When Off, special binary control codes may 
be intercepted per the Format item setting.
     Factory Defaults
Yes
No
No
Resets the menu to factory network defaults. 
     Connection Speed 
Auto-Sense 
100Mbit Half
100Mbit Full
10Mbit Half
10Mbit Full
Auto-Sense
Configures the Ethernet connection speed 
(10 or 100 Mbits/second) and 
communication mode (full or half duplex). 
The “Auto Sense” setting attempts to 
auto-negotiate this connection with the 
networking hardware, usually a switch. 
When a setting other than “Auto Sense” 
must be used, the following should be 
considered: If connected to network switch, 
the “100Mbit/Full” setting can be used. If 
connected to a hub, use the “100Mbit/Half” 
setting. 
     Bidirectional
On/Off
On
When this setting is “on”, the printer may 
receive and send information over the 
network interface. When this setting is “off”, 
the printer will only receive information 
over the network interface. This applies 
primarily when using printing over a “Port 
9100” connection. This setting normally 
should be left at its default setting, should 
only be turned “off” under special 
circumstances
.
     Wait timeout
0000-9999
0270
(In Seconds): Specifies the amount of time 
the printer will allow a network connection 
to remain open without transferring data 
before the printer terminates the connection.
     SNMP On/Off
On/Off
On
     HTTP Port
00000-99999
00080
Specifies the TCP port number to use for 
HTTP connection to the printers embedded 
web server.
     IP Filtering
Disabled
Enabled
Disabled
(available via web server only): Allows an 
administrator to control access to printing 
and access to the embedded web server on 
the basis of IP addresses. This is a security 
feature.
 USB Setup
This item allows you to set up the USB 
interface.
     Interpreter
Auto Switch
PCL
PostScript 3
Auto Switch
Menu Item
Value 
Default
Description
User’s Guide
3-13
Operator Panel Menus
Operator Panel
PS Menu
The PS menu allows you to Print PS Errors. Items available in this menu are described below
PCL Menu
The PCL menu allows to set a variety of PCL settings. Items available in this menu are 
described below
     Format
Raw
Normal
Binary
Raw
Configures how incoming print jobs are 
scanned for special binary control codes.
RAW=no processing
Normal = “Adobe Standard Protocol” (ASP)
Binary = “Binary Control Protocol” (BCP)
When Interpreter setting is Auto Switch and 
this setting is Raw, the printer will 
automatically determine the control code 
method, defaulting to Normal if no codes are 
found.
     Delay Out Close
On/Off
Off
When ON, the printer will wait until the job 
is completely printed and delivered to the 
output tray before terminating the 
connection, allowing all reverse-channel 
data to be sent back to the host. This will 
cause a reduction in printer throughput.
When OFF, reverse-channel data generated 
after the job interpretation is discarded. No 
reduction in printer throughput occurs.
     Binary PS
On/Off
On
When On, the feature allows all binary codes 
to be processed by the PostScript interpreter. 
When Off, special binary control codes may 
be intercepted per the Format item setting.
Parameter
Value 
Default
Description
Print PS Errors
On/Off
Off
Choose to either print or not print PS errors.
Parameter
Value 
Default
Description
Orientation
Portrait
Landscape
Portrait
Choose the orientation of the page. 
Font Source
Internal 
User FLASH
Hard Disk
Compact Flash
Internal
Choose the source of the default font.
Font Number
0-158
50
Set the default font number.
Menu Item
Value 
Default
Description
3-14
User’s Guide
Operator Panel Menus
Operator Panel
Pitch
0.08 - 100.00
10.00
Change the default pitch of text.
Symbol Set
All available 
symbol sets
10U:PC-8 CP437
Choose a default symbol set.
Lines Per Page
5-128
60/Letter
64/A4
Change the default number of lines per page. 
Default value varies by paper size selected.
CR Mode
CR=CR
CR=CR/LF
CR = CR
Define the default action prompted by a 
carriage return—a carriage return equals 
either a carriage return alone, or a carriage 
return and a line feed together.
LF Mode
LF=LF
LF=CR/LF
LF = LF
Define the default action prompted by a line 
feed—a line feed equals either a line feed 
alone or a carriage return and a line feed 
together.
FF Mode
FF=FF
FF=CR/FF
FF = FF
Define the default action prompted by a 
form feed—a form feed equals either a form 
feed alone or a carriage return and a form 
feed together.
Print Area
Normal
Expanded
Normal
Set the print area.
Parameter Values
submenu
     Paper Source
Tray 1 
Tray 2 
Tray 3
Tray 4
Auto-Select 
Varies per tray
Set the escape sequence for paper source.
     Paper Size
Executive
Letter
Legal
Invoice
Legal13
A6
A5
A4
B5
Monarch
Com10
DL
C5
Com9
Varies per size
Set the escape sequence for paper size.
Parameter
Value 
Default
Description
Page of 127
Display