DOWNLOAD Sharp AR-M351U / AR-M451U (serv.man17) Service Manual ↓ Size: 887.33 KB | Pages: 88 in PDF or view online for FREE

Model
AR-M351U AR-M451U (serv.man17)
Pages
88
Size
887.33 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Simulations
File
ar-m351u-ar-m451u-sm17.pdf
Date

Sharp AR-M351U / AR-M451U (serv.man17) Service Manual ▷ View online

AR-M351U/M451U, AR-M355U/M455U  SIMULATION  9 - 31
Operation/Procedure
1) Enter the tag number with 10-key.
2) Press [START] key.
Operation/Procedure
The operating conditions of sensors and detectors are displayed.
The active sensors and detectors are highlighted.
Operation/Procedure
The operating conditions of sensors and detectors are displayed.
The active sensors and detectors are highlighted.
Operation/Procedure
The operating conditions of sensors and detectors are displayed.
The active sensors and detectors are highlighted.
The paper width size detection level is displayed.
27-5
Purpose
Setting
Function
(Purpose)
Used to enter the machine tag No. (This function 
allows to check the tag No. of the machine with the 
host computer.)
Section
Communication unit (TEL/LIU/MODEM etc.)
Item
Specifications
Operation mode
30
30-1
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operation of sensors and 
detectors in other than the paper feed section and 
the operations of the related circuits.
Item
Operation
PPD1
Resist roller front paper detection 
POD1
After-fusing transport detection 1
POD2
After-fusing transport detection 2
POD3
Paper full detection
DSWL
Cabinet open detection
DSWF
Front door
30-2
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operation of sensors and 
detectors in the paper feed section and the related 
circuits.
Section
Paper feed
Item
Operation
SIMULATION 27-5
TAG # SETTING. INPUT VALUE, AND PRESS START.
PRESENT:  00010000
NEW:      
00009999
SIMULATION 30-1
SENSOR CHECK..
PPD1  POD1
POD2  
POD3
DSWL
DSWF
CSS1
Tray 1 insertion detection
PED
Tray 1 paper empty detection 
LUD
Tray 1 upper limit detection 
MCSET
MP unit detection 
MCDRS
MP unit side door open detection 
MCPPD
MP tray transport detection 
MCLUD
MP tray upper limit detection 
MCPED
MP tray paper empty detection 
MCSPD
MP tray remaining quantity detection 
MCSS1
MP tray size detection 1
MCSS2
MP tray size detection 2
MCSS3
MP tray size detection 3
MCSS4
MP tray size detection 4
MP Tray size
(The detection size of MP tray is displayed.)
MPFSET
Manual feed tray detection 
MPED
Manual feed tray paper empty detection 
MPLD
Manual feed length detection 
MPLS1
Manual feed pull-out sensor 1
MPLS2
Manual feed pull-out sensor 2
Bypass Tray size
(The detection size of manual feed tray is 
displayed.)
40
40-1
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operation of the manual feed 
tray paper size detector and the related circuit. 
(The operation of the manual feed tray paper size 
detector can be monitored with the LCD display.)
Section
Paper feed
Item
Operation
MPLD
Manual tray length detection
MPLS1
Manual tray pull-out detection 1
MPLS2
Manual tray pull-out detection 2
BYPASS_WIDTH
Manual feed guide plate position
BYPASS_AD
Manual feed width detection volume 
output AD value
Bypass Tray width 
size
(Manual tray detection size is displayed.)
A4/A3, 11 x, B5/B4, 8.5 x , A4R, B5R, 
A5R, 5.5x, 7.25x, EXTRA
SIMULATION 30-2
TRAY SENSOR CHECK..
CSS    PED   LUD
MCSET
  MCDRS MCPPD MCLUD MCPED MCSPD MCSS1 MCSS2
MCSS3  MCSS4     (MP Tray size: 
A4
 )
MPFSET
 MPED  MPLD  MPLS1 MPLS2
                 (Bypass Tray size: 
A3
 )
SIMULATION 40-1
BYPASS TRAY SENSOR CHECK..
MPLD
     MPLS1     MPLS2
BYPASS_WIDTH: 
2100
       BYPASS_AD: 
600
(Bypass Tray width size: 
A4/A3
)
AR-M351U/M451U, AR-M355U/M455U  SIMULATION  9 - 32
Operation/Procedure
1) Open the manual paper feed guide to the max. width.
2) Select MAX POSITION with 10-key.
3) Press [START] key.
The max. width detection level is recognized.
4) Press [CUSTOM SETTINGS] key.
5) Set the manual paper feed guide to A4R size width.
6) Select POSITION with 10-key.
7) Press [START] key.
The A4R width detection level is recognized.
8) Press [CUSTOM SETTINGS] key.
9) Set the manual paper feed guide to A5/A5R size width.
10) Select POSITION2 with 10-key.
11) Press [START] key.
The A5R width detection level is recognized.
12) Press [CUSTOM SETTINGS] key.
13) Open the manual paper feed guide to the min. width.
14) Select MIN POSITION with 10-key.
15) Press [START] key.
The min. width detection level is recognized.
If the above procedures are not completed normally, "ERROR" is
displayed. If completed normally, "COMPLETE" is displayed.
Operation/Procedure
1) Select the number corresponding to the set item with 10-key.
2) Press [START] key.
3) Enter the set value with 10-key.
4) Press [START] key.
Operation/Procedure
The operating conditions of sensors and detectors are displayed.
The active sensors and detectors are highlighted.
The paper width detection level is also displayed.
40-2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the manual paper feed tray paper 
width detector detection level.
Section
Paper feed
Item
Operation
Select 4 and press [START] key.
Press [CUSTOM SETTINGS] key.
SIMULATION 40-2
BYPASS TRAY ADJUSTMENT. SELECT 1-4, AND PRESS START.
1. MAX. POSITION
2. POSITION 1
3. POSITION 2
4. MIN. POSITION
1
SIMULATION 40-2
BYPASS TRAY ADJUSTMENT.
MAX. POSITION ··· COMPLETE (or "ERROR")
Press [CUSTOM SETTINGS] key.
SIMULATION 40-2
BYPASS TRAY ADJUSTMENT.
POSITION 1 ··· COMPLETE (or "ERROR")
Select 1 and press [START] key.
SIMULATION 40-2
BYPASS TRAY ADJUSTMENT.
POSITION 2 ··· COMPLETE (or "ERROR")
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key. 
Select 2 and press [START] key.
Select 3 and press [START] key.
SIMULATION 40-2
BYPASS TRAY ADJUSTMENT.
MIN. POSITION ··· COMPLETE (or "ERROR")
40-7
Purpose
Adjustment/Setup
Function
(Purpose)
Used to enter the manual paper feed tray paper 
width adjustment value.
Section
Paper feed
Item
Operation
1
MAX. POSITION
Max. width
2
POSITION 1
Adjustment point 1
3
POSITION 2
Adjustment point 2
4
MIN. POSITION
Min. value
Press [START] key.
Press [CUSTOM SETTINGS] key.
40-11
Purpose
Operation test/Check
Function
(Purpose)
Used to check the multi-purpose tray width detec-
tion adjustment value.
Section
Paper feed
Item
Operation
MCSS1
Tray 3 size detection 1
MCSS2
Tray 3 size detection 2
MCSS3
Tray 3 detection size 3
MCSS4
Tray 3 size detection 4
Multi Purpose 
Tray
(MPT width direction detection size is 
displayed.) A4/A3, 11X, B5/B4, 8.5X, A4R, 
B5R, A5R, 5.5X, 7.25X, EXTRA
SIMULATION 40-7
1
BYPASS TRAY VALUE SETTING. SELECT 1-4, AND PRESS START.
1. MAX. POSITION :   
66
2. POSITION 1  :    
447
3. POSITION 2  :    
704
4. MIN. POSITION :  
916
SIMULATION 40-7
BYPASS TRAY VALUE SETTING. INPUT VALUE 0-1023, AND PRESS
START.
1. MAX. POSITION
66
SIMULATION 40-11
TRAY3 SENSOR CHECK..
MCSS1
     MCSS2     MCSS3     MCSS4
(Multi Purpose Tray width size: 
A4/A3
)
AR-M351U/M451U, AR-M355U/M455U  SIMULATION  9 - 33
Operation/Procedure
1) Open the paper feed tray 2 paper feed guide to the max. width
position.
2) Select MAX POSITION with 10-key.
3) Press [START] key.
The max. width detection level is recognized.
4) Press [CUSTOM SETTINGS] key.
5) Open the paper feed tray 3 paper feed guide to the min. width
position.
6) Select MIN POSITION with 10-key.
7) Press [START] key.
The min. width detection level is recognized.
If the above procedures are not completed normally, "ERROR" is
displayed. If completed normally, "COMPLETE" is displayed.
Operation/Procedure
The operating conditions of sensors and detectors are displayed.
The active sensors and detectors are highlighted.
Operation/Procedure
1) Open the document cover and select NO ORIGINAL with 10-
key without placing any document on the document table.
2) Press [START] key.
The sensor level is set without document on the document
table.
3) Place an A3 document on the document table, and select A3
ORIGINAL with 10-key.
4) Press [START] key.
The sensor level is set when detection the document.
If the above procedures are not completed normally, "ERROR" is
displayed. If completed normally, "COMPLETE" is displayed.
Operation/Procedure
The detection output level (A/D value) of the document sensors
(PD1 - PD7) is displayed in real time.
The value in [ ] on the side of each sensor name indicates the
threshold value.
The light receiving value (A/D value) and the threshold value (A/D
value) of PD1 - PD7 are in the range of 1 - 255. The default of
threshold value is 128.
40-12
Purpose
Adjustment/Setup
Function
(Purpose)
Used to check the multi-purpose tray width 
detection adjustment value.
Section
Paper feed
Item
Operation
Press [START] key.
Press [CUSTOM SETTINGS] key.
41
41-1
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operation of the document size 
sensor and the related circuit. (The operation of 
the document size sensor can be monitored with 
the LCD display.)
Section
Other
Item
Operation
OCSW
Document cover 
status
Open: Normal display
Close: Highlighted
PD1 - 7
Document detection 
sensor status
No document: Normal display
Document present: Highlighted
SIMULATION 40-12
MULTI PURPOSE TRAY ADJUSTMENT. SELECT 1-2, AND PRESS
START.
1.MAX. POSITION
2.MIN. POSITION
1
SIMULATION 40-12
MULTI PURPOSE TRAY ADJUSTMENT.
MAX. POSITION ··· COMPLETE (or "ERROR")
Press [CUSTOM SETTINGS] key.
Select 1 and press [START] key. 
SIMULATION 40-12
MULTI PURPOSE TRAY ADJUSTMENT.
MIN. POSITION ··· COMPLETE (or "ERROR")
SIMULATION 41-1
PD SENSOR CHECK..
OCSW  
PD1
  
PD2
  
PD3
  PD4  PD5  PD6  PD7
41-2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the document size sensor sensing 
level.
Section
Other
Item
Operation
Select 2 and press [START] key. 
(Error)
Press [CUSTOM SETTINGS] 
key.
41-3
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operation of the document size 
sensor and the related circuit. (The document size 
sensor output level can be monitored with the LCD 
display.)
Section
Other
Item
Operation
OCSW
Original cover status
Open: Normal display
Close: Highlighted
PD1 - 7
PD sensor detection level The value in [ ] indicates the 
adjustment threshold value (SIM41-2 adjustment 
value).
SIMULATION 41-2
PD SENSOR ADJUSTMENT. SELECT1-2, AND PRESS START.
(PLEASE OPEN THE ORIGINAL COVER.) 
1. NO ORIGINAL
2. A3 ORIGINAL
1
SIMULATION 41-2
Press [CUSTOM SETTINGS] key. 
Select 1 and 
press [START] key. 
PD SENSOR ADJUSTMENT.
NO ORIGINAL ··· COMPLETE (or "ERROR at 
PD1 PD2
...")
A3 ORIGINAL ··· INCOMPLETE
SIMULATION 41-2
PD SENSOR ADJUSTMENT.
NO ORIGINAL ··· COMPLETE
A3 ORIGINAL ··· COMPLETE (or "ERROR at 
PD1 PD2
...")
AR-M351U/M451U, AR-M355U/M455U  SIMULATION  9 - 34
Operation/Procedure
1) Select the number corresponding to the setting mode with 10-
key.
2) Press [START] key.
3) Press [CUSTOM SETTINGS] key.
4) Press [START] key.
Operation/Procedure
When bit =1, correction is made.
Operation/Procedure
1) Select the number corresponding to the setting mode with 10-
key.
2) Press [START] key.
3) Enter the set value.
4) Press [START] key.
*1: Only when this value is 0, control is made with the actual mea-
surement value of the process thermistor (temperature/humid-
ity). When it is not 0, control is made with the forcible setting
value.
43
43-1
Purpose
Setting
Function
(Purpose)
Used to set the fusing temperature in each 
operation mode.
Section
Fixing (Fusing)
Item
Operation
Item
Default
1
INSIDE NORMAL
Heater inside/normal
190
2
OUTSIDE NORMAL
Heater outside/normal
190
3
INSIDE PREHEAT
Heater inside/preheat
150
4
OUTSIDE PREHEAT
Heater outside/preheat
150
Press [START] key.
Press [CUSTOM SETTINGS] key.
44
44-1
Purpose
Setting
Function
(Purpose)
Used to set enable/disable of correction 
operations in the image forming (process) section.
Section
Image process (Photoconductor/Developing/
Transfer/Cleaning)
Item
Operation
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
Vg4
Vb4
Ld4
Vbr
Vg3
Vb3
Ld3
Vb1
Vb2
Ld2
Vg2
Ld1
Vg1
SIMULATION 41-3
PD SENSOR DATA DISPLAY.
OCSW
PD1[128]: 200     PD2[128]: 200
PD3[128]:  50     PD4[128]:  52
PD5[128]:  51     PD6[128]:  50
PD7[128]:  52
SIMULATION 43-1
1
FUSER TEMPERATURE SET. SELECT 1-4, AND PRESS START.
1. INSIDE NORMAL 
190
2. OUTSIDE NORMAL 
190
3. INSIDE PREHEAT 
150
4. OUTSIDE PREHEAT 
150
SIMULATION 43-1
FUSER TEMPERATURE SET. INPUT VALUE, AND PRESS START.
1. INSIDE NORMAL
190
44-4
Purpose
Setup
Function
(Purpose)
Used to set the target image (reference) density 
level in the developing bias voltage correction. 
Section
Process 
(OPC drum, developing, transfer, cleaning)
Item
Data
Item
1
TEMP. AREA *1
Process environment temperature 
forcible setting value 
(0 - 13 /normal: 0)
2
HUMIDITY AREA *1
Process environment humidity 
forcible setting value 
(0 - 14 /normal: 0)
3
S_WT
Vb rising correction standby time
(0 - 180 sec/default: 90)
4
Vb1
Vb correction amount (first rotation) 
(0 - 150V/default: 50)
5
Vb2
Vb correction amount (second 
rotation) (0-50V/default: 15)
Press [START] key.
Press [CUSTOM SETTINGS] key.
SIMULATION 44-1
PROCESS CORRECTION VALUE SETTING. INPUT VALUE 0-255
AND PRESS START.
BIT0:Vg1, BIT1:Ld1, BIT2:Vg2,  BIT3:Ld2
BIT4:Vb1, Vb2
BIT5:Vg3, Vb3, Ld3
BIT6:Vbr   
BIT7:Vg4, Vb4, Ld4
111
SIMULATION 44-4
3
PROCESS CONTROL VALUE SETTING. SELECT 1-5 AND PRESS
START.
1.TEMP. AREA     
0
2.HUMIDITY AREA  
0
3.S_WT  
100
4.Vb1    
50
5.Vb2    
50
SIMULATION 44-4
PROCESS CONTROL VALUE SETTING. INPUT VALUE, AND PRESS
START.
3.S_WT
101