AR-M205 SIMULATIONS 7-4
02
11
SPF PS release solenoid operation 
check 
The SPF PS release solenoid (CLH) is turned ON for 500msec and OFF for 500msec. This operation 
is repeated 20 times. 
After completion of the process, the machine goes to the sub code input standby mode. When the 
[Interrupt] key is pressed during the process, the machine goes to the sub code input standby mode. 
When the [CA] key is pressed, the simulation is terminated.  
03
02
Shifter sensors status display
The shifter HP sensor is monitored. When the sensor is ON, the [Copier position jam lamp] is lighted. 
During this operation, the display section displays the sub code. When the [Interrupt] key is pressed, 
the machine goes to the sub code input standby mode. When the [CA] key is pressed, the simulation 
is terminated.
03
Shifter operation check
The shifter is reciprocated 4 times. During the process, the display section displays the sub code. 
After completion of the process, the machine goes to the sub code input standby mode. When the 
[Interrupt] key is pressed during the process, the machine goes to the sub code input standby mode. 
When the [CA] key is pressed, the simulation is terminated.    To stop the shifter, however, stop is in 
the home position. 
11
Shifter home position check
The shifter is moved in one direction by the specified steps. The 7-seg LED displays the sub code. 
While the shifter is moving, the shifter HP sensor is monitored. While the sensor is ON, the machine 
position jam lamp is lighted. 
When the [Interrupt] key is pressed during the process, the machine goes to the sub code input 
standby mode. When the [CA] key is pressed, the simulation is terminated.  
05
01
Operation panel display check 
<<LED check mode (ALL ON/Individual ON)>>
When the [START] key is pressed in the sub code input mode, all the LED's (including the 7-seg 
lamps) are turned ON. After 5 sec of all ON, the machine goes to the sub code input standby mode. 
When the [Mode select] key is pressed during all ON, the lighting mode is shifted to the individual ON 
mode, where the LED's are individually lighted from the left top, to the left bottom, to the next line top, 
to the bottom, and so on. (For the 7-seg lamps, the 3-digit lamps are lighted at once.) 
After completion of lighting of all the lamps, the mode is shifted to the all ON mode. 
After 5 sec of all ON mode, the machine goes to the sub code input standby mode. 
When the [Interrupt] key is pressed in the LCD check mode, the machine goes back to the sub code 
input standby mode. 
When the [CA] key is pressed, the simulation is terminated. 
When the [START] key is pressed with all the lamps ON, the machine goes back to the key input 
check mode. 
<< Key input check mode>>
When the machine goes into the key input check mode, [- - -] is displayed on the copy quantity 
display. Every time when a key on the operation panel is pressed, the input value is added on the 
copy quantity display. 
[- - -] 
 [  1] 
 [  2] 
 •••.
When a key is pressed once, it is not counted again. 
When the [START] key is pressed, the input number is added and displayed for 3 sec, and the 
machine goes into the LED lighting check mode (LED all ON state). When the [Interrupt] key is 
pressed for the first time, it is counted. When the key is pressed for the second time, the machine 
goes into the sub code input mode. When the [CA] key is pressed for the first time, it is counted. 
When the key is pressed for the second time, the simulation is terminated. (Note for the key input 
check mode). 
•Press the [START] key at the end. (When the key is pressed during the process, the machine goes
into the LED lighting check mode (all ON state).). 
•When two or more keys are pressed simultaneously, they are ignored. 
02
Fusing lamp and cooling fan 
operation check 
When the [START] key is pressed, the fusing lamp turns ON for 500ms and OFF for 500ms.
The operation is repeated 5 times. During this process, the cooling fan motor rotates.
After completion of the process, the machine goes into the sub code input standby mode.
03
Copy lamp lighting check 
When the [START] key is pressed, the copy lamp lights up for 5 sec. After completion of lighting, the 
machine goes into the sub code input mode. 
When the [Interrupt] key is pressed, the process is interrupted and the machine goes into the sub 
code input standby mode. When the [CA] key is pressed, the simulation is terminated. 
Main 
code
Sub 
code
Contents
Details of operation
3 key:
4 key:
5 key:
Step toward the front
Step toward the rear
Initial 
Individual ON mode cycle:
300ms for ON
20ms for OFF 
' !"#$
AR-M205 SIMULATIONS 7-5
06
01
Paper feed solenoid operation 
check 
When this simulation is executed, the sub code is displayed on the 7-seg LED and the lamp 
corresponding to the solenoid lights up. 
Select a solenoid with the tray select key (the lamp corresponding to the solenoid lights up) and 
press the [START] key, and the machine repeats operation of ON for 500ms and OFF for 500ms.
This operation is repeated 20 times.
After that, the machine goes into the sub code entry standby mode. 
02
Resist roller solenoid operation 
check
When the [START] key is pressed in the sub code input state, the resist solenoid (RRS) turns ON for 
500ms and OFF for 500ms. This operation is repeated 20 times. 
After completion of the process, the machine goes into the sub code input standby mode. 
10
Main cassette semicircular roller 
cleaning
The main motor is rotated to rotate the semicircular roller of the main cassette one turn to face the 
semicircular roller down. (Remove the developing layer when performing this operation.)
During this process, the sub code is displayed on the display section.
After completion of the process, the machine goes into the sub code input standby mode. 
07
01
Warm-up display and aging with 
jam
Copying is repeated to make the set copy quantity. When this simulation is executed, warm-up is 
started and warm-up time is counted up every second from 0 and displayed. After completion of 
warm-up, warm-up time count is stopped. When the [CA] key is pressed, the ready lamp lights up. 
After that, when the copy quantity is inputted with keys and the [START] key is pressed, copying is 
repeated to make the set copy quantity. (Intermittent 0 sec)This simulation is canceled by turning off 
the power or performing a simulation that executes hardware reset. 
06
Intermittent aging
Copying is repeated to make the set copy quantity. When this simulation is performed, warm-up is 
performed and the ready lamp is lighted. Enter the copy quantity with the key and press the [START] 
key, and copying is repeated to make the set copy quantity, the ready state remains for 3 sec, and 
copying is repeated again to make the set copy quantity. These operations are repeated. 
This simulation is canceled by turning off the power or performing a simulation that executes 
hardware reset.
08
Shifting with warm-up display 
(Shifting similar to pressing the CA 
key)
When the simulation code is entered, warm-up is started and warm-up time is counted up every 
second from 0 and displayed. When the [CA] key is pressed during counting up, the display section 
displays "0" and count-up process stops. However, warm-up is continued. 
After completion of warm-up, counting is stopped. Press the [CA] key to terminate the simulation 
mode. (This simulation is similar to SIM07-01, but without the aging function.)
08
01
Developing bias output
When the [START] key is pressed, the developing bias signal is turned ON for 30 sec. 
However, to calculate the actual output value is calculated, execute SIM25-01.
After completion of the process, the machine goes into the sub code input standby mode. 
02
Main charger output (Grid = HIGH) When the [START] key is pressed, the main charger output is supplied for 30 sec in the grid voltage 
HIGH mode. After completion of the process, the machine goes into the sub code input standby 
mode.
03
Main charger output (Grid = LOW) When the [START] key is pressed, the main charger output is supplied for 30 sec in the grid voltage 
LOW mode. After completion of the process, the machine goes into the sub code input standby 
mode.
06
Transfer charger output
Select an output mode with the [Mode select] key and press the [START] key. The transfer charger 
output is delivered for 30 sec in the selected mode. 
After 30 sec of transfer charger output, the machine goes into the sub code entry standby mode. 
Main 
code
Sub 
code
Contents
Details of operation
*
Supported for the installed models only. Skipped for the models without installation.
Display lamp
Solenoid
Main cassette lamp 
2nd cassette lamp
3rd cassette lamp
4th cassette lamp
Manual paper feed lamp
2nd cassette jam lamp
Machine jam lamp & 2nd cassette jam lamp
Main cassette paper feed solenoid
* 2nd cassette paper feed solenoid
* 3rd cassette paper feed solenoid
* 4th cassette paper feed solenoid
Manual paper feed solenoid
* 2nd cassette paper transport solenoid
* 3rd cassette transport solenoid
•Small size is Letter R (A4R) or smaller.
Display lamp
Output mode
AE mode lamp
TEXT mode lamp
AE mode lamp & PHOTO mode lamp
TEXT mode lamp & PHOTO mode lamp
AE & TEXT & PHOTO mode lamp 
Normal size width: Front surface
Normal size width: Back surface
Small size width: Front surface
Small size width: Back surface
Manual paper feed mode
( !"#$
AR-M205 SIMULATIONS 7-6
09
01
Duplex motor forward rotation 
check
The duplex motor is driven in forward direction (in the paper exit direction) for 30 sec. 
During the process, the display section displays the sub code. 
After completion of the process, the machine goes into the sub code input standby mode. 
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode. 
When the [CA] key is pressed, the simulation is terminated. 
02
Duplex motor reverse rotation 
check
The duplex motor is driven in reverse direction for 30 sec. 
During the process, the display section displays the sub code. 
After completion of the process, the machine goes into the sub code input standby mode. 
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode. 
When the [CA] key is pressed, the simulation is terminated.
04
Duplex motor RPM adjustment 
When any key input is made, it is displayed on the display section. 
When the [START] key is pressed, the set code data are acquired and stored in the EEPROM, and 
the machine goes into the sub code input standby mode. 
When, however, the [START] key is pressed outside the set range, it is not assured. 
At that time, when the [Interrupt] key is pressed, the data are not rewritten and the machine goes into 
the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated without rewriting the data. 
05
Duplex motor switchback time 
adjustment
When any key input is made, it is displayed on the display section. When the [START] key is pressed, 
the set code data are acquired and stored in the EEPROM, and the machine goes into the sub code 
input standby mode.
At that time, when the [Interrupt] key is pressed, the data are not rewritten and the machine goes into 
the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated without rewriting the data.
10
-
Toner motor operation 
When the [START] key is pressed, the toner motor is driven for 30 sec.
After completion of the process, the machine goes into the main code input standby mode. 
When the [Interrupt] key is pressed, the machine goes into the main code input standby mode. 
14
-
Trouble cancel (except for U2) 
*
Trouble to write into the EEPROM such as H trouble is canceled and hardware reset is
performed. 
16
-
U2 trouble cancel
*
U2 trouble is canceled and hardware reset is performed. 
20
01
Maintenance counter clear
When the [Start] key is pressed, the maintenance count value is cleared and "000000" is displayed. 
(Alternate display of "000" and "000")
21
01
Maintenance cycle setting
The current set maintenance cycle code is displayed (initial display), and the set data are stored. 
02
Mini maintenance cycle setting 
(Valid only when the destination is 
set to Japan AB series.)
The current set maintenance cycle code is displayed (initial display), and the set data are stored.
22
01
Maintenance counter display
The maintenance counter value is displayed. 
02
Maintenance preset display (Valid 
only when the destination is set to 
EX Japan)
The copy quantity corresponding to the code that is set with SIM21-01 is displayed. 
(For example: 50,000 sheets)
03
Jam memory display
The LED of the latest jam position is lighted. Every time when the magnification ratio display key is 
pressed, the jam memory data is acquired sequentially from the latest. The jam position is judged by 
the acquired data and the corresponding LED is lighted. The 7-seg display indicates the jam number. 
At that time, "A" is displayed on the upper first digit. When the last one is displayed, the latest one will 
be displayed again.  Max. 30 jams from the latest are stored. When the [Interrupt] key is pressed, the 
machine goes into the sub code input standby mode. When the [CA] key is pressed, the simulation is 
terminated. 
04
Jam total counter display
The jam total counter value is displayed.
05
Total counter display
The total counter value is displayed. 
06
Developing counter display
The developing counter data is acquired and displayed on the 7-seg display. 
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode. 
When the [CA] key is pressed, the simulation is terminated.
Main 
code
Sub 
code
Contents
Details of operation
Set range: 1 - 13
Default: 4
(Change quantity 1 
 1-2 phase 3 steps)
Set range: 50 ~ 76
Default: 50
Code
Setting
0
1
2
3
4
5
5,000 sheets
7,500 sheets
10,000 sheets
25,000 sheets
50,000 sheets                * Default
Free (999,999 sheets)
Code
Setting
0
1
2
5,000 sheets              * Default
10,000 sheets
Free (999,999 sheets)
) !"#$
AR-M205 SIMULATIONS 7-7
22
07
Mini maintenance preset display 
(Valid only when the destination is 
set to Japan AB series)
The mini maintenance cycle data is acquired and displayed on the 7-seg display. 
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
08
SPF counter display 
The SPF counter value is displayed. 
09
Paper feed counter display
The counter value of the selected paper feed section is acquired from each variable, the data is 
displayed on the 7-seg display according to the regulations. When this simulation is executed, the 
value of the first cassette is displayed first. Press the tray select key to select the paper feed tray. 
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
12
Drum counter display
The drum counter and the drum rotating time are displayed.
To change the display mode, press the [Mode select] key.
13
CRUM destination display
When this simulation is executed, the CRUM destination set (written) in the CRUM chip is displayed. 
This simulation is valid only for the models where the CRUM is valid. 
14
P-ROM version display
The P-ROM version is displayed on the copy quantity display. The main code and the sub code are 
alternatively displayed by 2 digits. The display interval is same as that of the counter display. 
By pressing the fixed magnification ratio key, each version display is switched. 
15
Trouble memory display
The trouble codes up to the latest one are acquired from the trouble memory data. 
Every time when the magnification ratio display is pressed, the main code of the trouble is displayed 
on the 1st ~ 2nd digit. 
*
The latest 20 troubles are stored in the memory.
The 3rd digit indicates the trouble history code, "A" ~ "J" (meaning of 1 ~ 10). 
After "J" is displayed, "A" ~ "J" blinks. (Meaning of 11 ~ 20)
After "J" blinks (meaning of 20), "A" ~ "J" is lighted. (Returns to 1.)
When the [START] key is pressed, the sub code is displayed. 
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode. 
When the [CA] key is pressed, the simulation is terminated.
*
Note that when the history code blinks, the trouble code and the sub code do not blink.  
16
Duplex print counter display
Data is acquired from the duplex print counter variable, and is displayed.
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode. 
When the [CA] key is pressed, the simulation is terminated.
17
Copy counter display
The copy counter value is displayed. When the [Interrupt] key is pressed, the machine goes into the 
sub code input standby mode. When the [CA] key is pressed, the simulation is terminated.
18
Printer counter display
The printer counter value is displayed. When the [Interrupt] key is pressed, the machine goes into the 
sub code input standby mode. When the [CA] key is pressed, the simulation is terminated.
19
Scanner mode counter display
The scanner mode counter value is displayed. When the [Interrupt] key is pressed, the machine goes 
into the sub code input standby mode. When the [CA] key is pressed, the simulation is terminated.
21
Scanner counter display
The scanner counter value is displayed. When the [Interrupt] key is pressed, the machine goes into 
the sub code input standby mode. When the [CA] key is pressed, the simulation is terminated.
22
SPF jam counter display
The SPF jam counter value is displayed. When the [Interrupt] key is pressed, the machine goes into 
the sub code input standby mode. When the [CA] key is pressed, the simulation is terminated.
24
01
Jam total counter clear
When the [START] key is pressed, the jam total count value is reset to zero, and zero is displayed. 
02
Trouble memory clear
The trouble memory and the EEPROM trouble history data are cleared and "000" is displayed on the 
7-seg display. When the [Interrupt] key is pressed, the machine goes into the sub code input standby 
mode. When the [CA] key is pressed, the simulation is terminated.
04
SPF counter clear
When the [START] key is pressed, the SPF count value is reset to zero and displayed on the 7-seg 
display. When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode. 
When the [CA] key is pressed, the simulation is terminated.
05
Duplex print counter clear
The duplex print count data is cleared, and zero is displayed on the 7-seg display. 
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode. 
When the [CA] key is pressed, the simulation is terminated.
06
Paper feed counter clear
The paper feed counter data of each paper feed section is cleared, and "000" is displayed on the 7-
seg display. When the [Interrupt] key is pressed, the machine goes into the sub code input standby 
mode. When the [CA] key is pressed, the simulation is terminated.
Main 
code
Sub 
code
Contents
Details of operation
Display lamp
AE mode lamp
TEXT mode lamp
Display mode
Drum counter
Drum rotating time
7-seg display
Meaning (CRUM destination)
7-seg display
Meaning (CRUM destination)
00
01
02
03
Not set yet
BTA-A
BTA-B
BTA-C
04
99
12
BTA-E
Conversion
AL series
Display lamp (AB series)
Display lamp (Inch series)
Displayed version
141%
115%
141%
121%
Machine program
IMC program
 !"#$
Page of 92
Display

Click on the first or last page to see other AR-M160 (serv.man14) service manuals if exist.