DOWNLOAD Sharp AR-M160 (serv.man14) Service Manual ↓ Size: 13.01 MB | Pages: 92 in PDF or view online for FREE

Model
AR-M160 (serv.man14)
Pages
92
Size
13.01 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual
File
ar-m160-sm14.pdf
Date

Sharp AR-M160 (serv.man14) Service Manual ▷ View online

AR-M205 SIMULATIONS 7-14
46
18
Image contrast adjustment 
(300dpi)
Used to adjust the contrast for each mode.
(Operating procedure)
When this simulation is executed, warm-up and shading are performed, and the current set value is 
displayed in two digits. (Default: 50)
*
The density LED is not lighted. 
Change the set value and press the [START] key, and a copy is made according to the set value. 
The greater the set value is, the higher the contrast is. 
The smaller the set value is, the lower the contrast is. 
In this case, only a copy at Exp. 3 is made. 
However, the contrasts at Exp.1 and Exp. 5 are also changed accordingly. 
To select a desired copy mode, press the [Copy mode select] key. 
The selected copy mode set value is displayed on the copy quantity display. 
(Adjustment range: 1 ~ 99)
19
Exposure mode setting 
(Gamma table setting / AE 
operation mode setting / PHOTO 
image process setting)
Used set for the following three exposure mode. Enter a code number and press the [START] key, 
and the entered number is written into the EEPROM and the machine goes into the sub code entry 
standby mode. (When the [Copy mode select] key is pressed, the number is written into the 
EEPROM and the set item is changed.)
<<Gamma table setting>>
When this simulation is executed, the current set code number of gamma table is displayed. 
(Default: Japan -1. EX Japan -2)
*
 When setting the gamma table, no "Mode lamps" are lighted.
*
If this setting is changed, the set content of SIM46-30 is reset to the default. 
<<AE mode>>
When the [Copy mode select] key is pressed in gamma table setting, the mode is changed to the AE 
operation mode setting and the current set code number of the AE operation mode is displayed. 
(Default: 0)
*
When setting the AE operation mode, the "AE mode lamp" is lighted. 
<Photo image process setting>
When the [Copy mode select] key is pressed during the AE operation mode setting, the setting mode 
is changed to the photo image process setting and the currently set code number of the photo image 
process setting is displayed.
*
When in the photo image process setting, the [Photo mode lamp] is lighted.
*
When this setting is changed, SIM 46-1/2/18/29 and SIM 46-31 Photo items are reset to the
default. (SIM 46-11 is also linked.)
Main 
code
Sub 
code
Contents
Details of operation
Display lamp
Copy mode
AE mode lamp
TEXT mode lamp
PHOTO mode lamp
TEXT mode lamp & PHOTO mode lamp
AE mode lamp & PHOTO mode lamp
AE mode (300dpi)
TEXT mode (300dpi)
PHOTO mode 
TS mode (TEXT) (300dpi)
TS mode (AE) (300dpi)
Code number
Setting (Gamma table)
1
2
Image quality priority mode                      * Default for Japan models
Toner consumption priority mode           * Default for EX Japan models
Code number
Setting (AE operation mode)
0
1
Lead edge stop                                         * Default
Rear time process
Code number
Setting (Photo image process setting)
1
Error diffusion process
Dither process                              * Default
' !"#$
AR-M205 SIMULATIONS 7-15
46
20
SPF exposure correction
Used to adjust the exposure correction amount in the SPF mode (for the OC mode).
(Operating procedure)
When this simulation is executed, the current set value is displayed. 
Enter the adjustment value with the 10-key and press the [START] key. 
The entered set value is stored and a copy is made. 
When the [INTERRUPT] key is pressed, the entered value is saved and the machine goes into the 
sub code entry standby mode. When the [CA] key is pressed, the entered value is saved and the 
simulation is terminated.  [1] ~ [99] (Center [50])
*
The greater the set value is, the darker the density is. The smaller the set value is, the lighter the
density is.
*
The exposure mode is TEXT fixed. The LED does not change, either. 
The exposure level can not be adjusted. 
29
Image contrast adjustment 
(600dpi)
Used to adjust the contrast for each mode. 
(Operating procedure)
When this simulation is executed, warm-up and shading are performed, and the current set value is 
displayed in two digits. (Default: 50)
The density LED is not lighted. 
Change the set value and press the [START] key, and a copy is made according to the set value. 
The greater the set value is, the higher the contrast is. 
The smaller the set value is, the lower the contrast is. 
In this case, only a copy at Exp. 3 is made. 
However, the contrasts at Exp.1 and Exp. 5 are also changed accordingly. 
To select a desired copy mode, press the [Copy mode select] key. 
The selected copy mode set value is displayed on the copy quantity display. 
(Adjustment range: 1 ~ 99)
30
AE limit setting
Used to set the AE and the limit value at AE (toner save).The set range is 0 ~ 31. The default is 0.
Change the setting and press the [START] key, and it will be written into the EEPROM and the 
machine will go into the sub code input standby mode. When the [Copy mode select] key is pressed, 
the machine goes back to the gamma table setting mode. 
<Remark>
When SIM26-60 (Destination setting) and SIM46-19 (Auto exposure mode) are changed, this set 
content of this simulation is also changed to the default.
31
Image sharpness adjustment
Used to adjust clear/shading of image for each mode. 
(Operating procedure)
When this simulation is executed, warm-up and shading are performed, and the current set value is 
displayed in two digits. (Default: 1)
Change the set value and press the [START] key, and a copy is made according to the set value.
Use the [Copy mode select] key to select each copy mode. The code number of the selected copy 
mode is displayed on the copy quantity display.
Main 
code
Sub 
code
Contents
Details of operation
Display lamp
Copy mode
AE mode lamp
TEXT mode lamp
PHOTO mode lamp
TEXT mode lamp & PHOTO mode lamp
AE mode lamp & PHOTO mode lamp
AE mode (600dpi)
TEXT mode (600dpi)
PHOTO mode 
TS mode (TEXT) (600dpi)
TS mode (AE) (600dpi)
Display lamp
Setting mode
AE mode lamp
AE mode lamp $ PHOTO mode lamp
Limit value for AE
Limit value for AE (Toner save)
Set value
Image quality
0
1
2
Shading
Standard                                   *Default
Clear
Display lamp
Copy mode
AE mode lamp
TEXT mode lamp
PHOTO mode lamp
TEXT mode lamp & PHOTO mode lamp
AE mode lamp & PHOTO mode lamp
AE mode
TEXT mode
PHOTO mode
TS mode (TEXT)
TS mode (AE)
( !"#$
AR-M205 SIMULATIONS 7-16
48
01
Main scanning/sub scanning 
direction magnification ratio 
adjustment
Used to adjust the magnification ratio in the main scanning direction (front/rear) and the sub 
scanning direction. 
Enter the adjustment value with the 10-key and press the [START] key, and the entered value is 
saved a copy is made. 
(When the set value is increased by 1, the magnification ratio is increased by 0.1 %.)
 (Adjustment range: 1 ~ 99,  Default: 50)
05
SPF/RSPF mode sub scanning 
magnification ratio adjustment in 
copying
The current SPF/RSPF mode sub scan direction magnification ratio adjustment value is displayed. 
When the [START] key is pressed, the entered value is acquired and saved into the EEPROM, and a 
copy is made. When the [CA] key is pressed instead, the simulation mode is terminated.
In RSPF adjustment, after the machine enters the copy mode of one page, select the single copy 
mode with the duplex key to shift to the single copy mode, making two pages of single copy. 
For printing, regardless of the density mode LED and the density level LED display, the density mode 
= MANUAL, and density level = 3.
49
01
Flash ROM program writing mode
(Operating procedure)
When this simulation is executed, "d" is displayed on the copy quantity display and the machine 
enters the Flash ROM program writing mode. Use the writing tool on the PC to write the program. 
During writing, the display is made as follows. After completion of downloading, turn OFF/ON the 
power to reset. 
 *
"*" in the error display indicates the error position. 
Main 
code
Sub 
code
Contents
Details of operation
Lighting lamp
Adjustment mode
TEXT lamp
PHOTO lamp
Main scanning direction magnification ratio adjustment
Sub scanning direction magnification ratio adjustment
Lighting lamp
Adjustment mode
AE lamp
TEXT lamp
SPF/RSPF document surface magnification ratio adjustment
RSPF document back magnification ratio adjustment
Status
Copy quantity display
Pre-heat lamp
Ready lamp
Download data reception
Data delete start
Data writing (Boot section)
Data writing (Program section)
Sum check
Completion of downloading
Error status
"d"
"d"
"d"
"d"
"d"
"OFF"
"*E"
ON
ON
Flash
Flash
ON
OFF
OFF
OFF
ON
OFF
Flash
ON
OFF
OFF
1. Data reception error
2. Loader function transfer
3. Flash ROM delete
4. Flash ROM writing (Boot section)
5. Flash ROM writing (Program section)
6. Sum check (Loader section)
7. Sum check (Boot section)
8. Sum check (Program section)
) !"#$
AR-M205 SIMULATIONS 7-17
50
01
Image lead edge adjustment
Used to adjust the copy image position and the lead edge void amount on the copy paper. This 
adjustment is made by adjusting the image scan start position at 100% and the print start position 
(resist roller ON timing). 
(Operating procedure)
When this simulation is executed, the current set value is displayed in two digits. (Center value: 50) 
When the copy mode select key is pressed, the setting mode and the display are switched. Enter the 
adjustment value with the 10-key and press the [START] key, and the entered value is set and a copy 
is made. (Adjustment range 1 ~ 99) When the [INTERRUPT] key is pressed, the entered value is 
saved and the machine goes into the sub code entry standby mode. When the [CA] key is pressed, 
the entered value is saved and the simulation is terminated. When the adjustment is made with the 
main cassette paper feed, all the adjustment values at the paper feed ports become the same. 
(When the adjustment value is increased by 1, the position is shifted by about 0.1mm.)
*
The mark, "
", indicates that it is supported only for the installed model, and it is skipped for
non-installed models.
Note: When printing is made with manual paper feed, use A3 paper. 
When the adjustment value of the print start position is increased by 1, the resist roller ON
timing is delayed and the print image is reduced by 0.1mm. When the adjustment value of the
image scan start position is increased by 1, the scan start position is shifted to the home
position by 0.1mm.
[Adjustment procedure]
(1) Set the print start position (A) (AE ON), the lead edge void amount (B) (TEXT ON), and the scan
start position (C) (PHOTO ON) to <1>, and make a 100% copy.
(2) Measure the image loss (R mm) of the scale. Set as C=10 x R (mm). (Example: Set to 40.)
When the value of C is increased by 10, the image loss is decreased by 1mm. (Default: 50)
(3) Measure the distance between the paper lead edge and the image print start position.
Set as A=10 x H (mm). (Example: Set to 50.)
When the value of A is increased by 10, the image lead edge is shifted toward the paper lead
edge by 1mm. (Default: 50)
(4) Set the lead edge void area as B=50 (2.5mm). (Default: 50)
When the value of B is increased by 10, the void is increased by about 1mm.
(For 25 or less, however, the void amount is zero.)
(Example)
06
Copy lead edge position 
adjustment (SPF/RSPF)
Used to make the SPF copy lead edge position adjustment. 
*
When the adjustment value of the document scan start position is increased by 1, the scan start
timing is advanced by 0.1mm. The print image is shifted to the reverse side of the scan start
position.
(Adjustment range: 1 ~ 99, Default: 50)
<Adjustment items>
Main 
code
Sub 
code
Contents
Details of operation
Lighting lamp
Adjustment mode
AE, Main cassette lamp
AE, 2nd cassette lamp
AE, Manual paper feed lamp
TEXT lamp
PHOTO lamp
AE, TEXT, PHOTO lamp
Print start position (Main cassette paper feed)
 Print start position (2nd cassette paper feed)
Print start position (Manual paper feed)
Image lead edge void amount
Image scan start position
Image rear edge void amount
5mm
10mm
Image loss 
R=4mm
Distance from the paper lead edge 
to the image lead edge H = 5mm
Lighting lamp
Item
Default
Variable range
AE
TEXT
PHOTO
Front document scan position adjustment
Back document scan position adjustment
Rear edge void adjustment (SPF)
50
50
50
1 ~ 99
1 ~ 99
1 ~ 99
 !"#$
Page of 92
Display