DOWNLOAD Sharp AR-M160 (serv.man14) Service Manual ↓ Size: 13.01 MB | Pages: 92 in PDF or view online for FREE

Model
AR-M160 (serv.man14)
Pages
92
Size
13.01 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual
File
ar-m160-sm14.pdf
Date

Sharp AR-M160 (serv.man14) Service Manual ▷ View online

AR-M205 SIMULATIONS 7-6
09
01
Duplex motor forward rotation 
check
The duplex motor is driven in forward direction (in the paper exit direction) for 30 sec. 
During the process, the display section displays the sub code. 
After completion of the process, the machine goes into the sub code input standby mode. 
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode. 
When the [CA] key is pressed, the simulation is terminated. 
02
Duplex motor reverse rotation 
check
The duplex motor is driven in reverse direction for 30 sec. 
During the process, the display section displays the sub code. 
After completion of the process, the machine goes into the sub code input standby mode. 
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode. 
When the [CA] key is pressed, the simulation is terminated.
04
Duplex motor RPM adjustment 
When any key input is made, it is displayed on the display section. 
When the [START] key is pressed, the set code data are acquired and stored in the EEPROM, and 
the machine goes into the sub code input standby mode. 
When, however, the [START] key is pressed outside the set range, it is not assured. 
At that time, when the [Interrupt] key is pressed, the data are not rewritten and the machine goes into 
the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated without rewriting the data. 
05
Duplex motor switchback time 
adjustment
When any key input is made, it is displayed on the display section. When the [START] key is pressed, 
the set code data are acquired and stored in the EEPROM, and the machine goes into the sub code 
input standby mode.
At that time, when the [Interrupt] key is pressed, the data are not rewritten and the machine goes into 
the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated without rewriting the data.
10
-
Toner motor operation 
When the [START] key is pressed, the toner motor is driven for 30 sec.
After completion of the process, the machine goes into the main code input standby mode. 
When the [Interrupt] key is pressed, the machine goes into the main code input standby mode. 
14
-
Trouble cancel (except for U2) 
*
Trouble to write into the EEPROM such as H trouble is canceled and hardware reset is
performed. 
16
-
U2 trouble cancel
*
U2 trouble is canceled and hardware reset is performed. 
20
01
Maintenance counter clear
When the [Start] key is pressed, the maintenance count value is cleared and "000000" is displayed. 
(Alternate display of "000" and "000")
21
01
Maintenance cycle setting
The current set maintenance cycle code is displayed (initial display), and the set data are stored. 
02
Mini maintenance cycle setting 
(Valid only when the destination is 
set to Japan AB series.)
The current set maintenance cycle code is displayed (initial display), and the set data are stored.
22
01
Maintenance counter display
The maintenance counter value is displayed. 
02
Maintenance preset display (Valid 
only when the destination is set to 
EX Japan)
The copy quantity corresponding to the code that is set with SIM21-01 is displayed. 
(For example: 50,000 sheets)
03
Jam memory display
The LED of the latest jam position is lighted. Every time when the magnification ratio display key is 
pressed, the jam memory data is acquired sequentially from the latest. The jam position is judged by 
the acquired data and the corresponding LED is lighted. The 7-seg display indicates the jam number. 
At that time, "A" is displayed on the upper first digit. When the last one is displayed, the latest one will 
be displayed again.  Max. 30 jams from the latest are stored. When the [Interrupt] key is pressed, the 
machine goes into the sub code input standby mode. When the [CA] key is pressed, the simulation is 
terminated. 
04
Jam total counter display
The jam total counter value is displayed.
05
Total counter display
The total counter value is displayed. 
06
Developing counter display
The developing counter data is acquired and displayed on the 7-seg display. 
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode. 
When the [CA] key is pressed, the simulation is terminated.
Main 
code
Sub 
code
Contents
Details of operation
Set range: 1 - 13
Default: 4
(Change quantity 1 
 1-2 phase 3 steps)
Set range: 50 ~ 76
Default: 50
Code
Setting
0
1
2
3
4
5
5,000 sheets
7,500 sheets
10,000 sheets
25,000 sheets
50,000 sheets                * Default
Free (999,999 sheets)
Code
Setting
0
1
2
5,000 sheets              * Default
10,000 sheets
Free (999,999 sheets)
) !"#$
AR-M205 SIMULATIONS 7-7
22
07
Mini maintenance preset display 
(Valid only when the destination is 
set to Japan AB series)
The mini maintenance cycle data is acquired and displayed on the 7-seg display. 
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
08
SPF counter display 
The SPF counter value is displayed. 
09
Paper feed counter display
The counter value of the selected paper feed section is acquired from each variable, the data is 
displayed on the 7-seg display according to the regulations. When this simulation is executed, the 
value of the first cassette is displayed first. Press the tray select key to select the paper feed tray. 
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
12
Drum counter display
The drum counter and the drum rotating time are displayed.
To change the display mode, press the [Mode select] key.
13
CRUM destination display
When this simulation is executed, the CRUM destination set (written) in the CRUM chip is displayed. 
This simulation is valid only for the models where the CRUM is valid. 
14
P-ROM version display
The P-ROM version is displayed on the copy quantity display. The main code and the sub code are 
alternatively displayed by 2 digits. The display interval is same as that of the counter display. 
By pressing the fixed magnification ratio key, each version display is switched. 
15
Trouble memory display
The trouble codes up to the latest one are acquired from the trouble memory data. 
Every time when the magnification ratio display is pressed, the main code of the trouble is displayed 
on the 1st ~ 2nd digit. 
*
The latest 20 troubles are stored in the memory.
The 3rd digit indicates the trouble history code, "A" ~ "J" (meaning of 1 ~ 10). 
After "J" is displayed, "A" ~ "J" blinks. (Meaning of 11 ~ 20)
After "J" blinks (meaning of 20), "A" ~ "J" is lighted. (Returns to 1.)
When the [START] key is pressed, the sub code is displayed. 
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode. 
When the [CA] key is pressed, the simulation is terminated.
*
Note that when the history code blinks, the trouble code and the sub code do not blink.  
16
Duplex print counter display
Data is acquired from the duplex print counter variable, and is displayed.
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode. 
When the [CA] key is pressed, the simulation is terminated.
17
Copy counter display
The copy counter value is displayed. When the [Interrupt] key is pressed, the machine goes into the 
sub code input standby mode. When the [CA] key is pressed, the simulation is terminated.
18
Printer counter display
The printer counter value is displayed. When the [Interrupt] key is pressed, the machine goes into the 
sub code input standby mode. When the [CA] key is pressed, the simulation is terminated.
19
Scanner mode counter display
The scanner mode counter value is displayed. When the [Interrupt] key is pressed, the machine goes 
into the sub code input standby mode. When the [CA] key is pressed, the simulation is terminated.
21
Scanner counter display
The scanner counter value is displayed. When the [Interrupt] key is pressed, the machine goes into 
the sub code input standby mode. When the [CA] key is pressed, the simulation is terminated.
22
SPF jam counter display
The SPF jam counter value is displayed. When the [Interrupt] key is pressed, the machine goes into 
the sub code input standby mode. When the [CA] key is pressed, the simulation is terminated.
24
01
Jam total counter clear
When the [START] key is pressed, the jam total count value is reset to zero, and zero is displayed. 
02
Trouble memory clear
The trouble memory and the EEPROM trouble history data are cleared and "000" is displayed on the 
7-seg display. When the [Interrupt] key is pressed, the machine goes into the sub code input standby 
mode. When the [CA] key is pressed, the simulation is terminated.
04
SPF counter clear
When the [START] key is pressed, the SPF count value is reset to zero and displayed on the 7-seg 
display. When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode. 
When the [CA] key is pressed, the simulation is terminated.
05
Duplex print counter clear
The duplex print count data is cleared, and zero is displayed on the 7-seg display. 
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode. 
When the [CA] key is pressed, the simulation is terminated.
06
Paper feed counter clear
The paper feed counter data of each paper feed section is cleared, and "000" is displayed on the 7-
seg display. When the [Interrupt] key is pressed, the machine goes into the sub code input standby 
mode. When the [CA] key is pressed, the simulation is terminated.
Main 
code
Sub 
code
Contents
Details of operation
Display lamp
AE mode lamp
TEXT mode lamp
Display mode
Drum counter
Drum rotating time
7-seg display
Meaning (CRUM destination)
7-seg display
Meaning (CRUM destination)
00
01
02
03
Not set yet
BTA-A
BTA-B
BTA-C
04
99
12
BTA-E
Conversion
AL series
Display lamp (AB series)
Display lamp (Inch series)
Displayed version
141%
115%
141%
121%
Machine program
IMC program
 !"#$
AR-M205 SIMULATIONS 7-8
24
07
Drum counter clear
When the [START] key is pressed, the drum count and the drum roasting time are reset to zero, and 
the drum counter value is displayed on the 7-seg LED. When the [Interrupt] key is pressed, the 
machine goes into the sub code input standby mode. When the [CA] key is pressed, the simulation is 
terminated.
08
Copy counter clear
When the [START] key is pressed, the copy count value is reset to zero and displayed on the 7-seg 
display. When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode. 
When the [CA] key is pressed, the simulation is terminated.
09
Printer counter clear
When the [START] key is pressed, the printer count value is reset to zero and displayed on the 7-seg 
display. When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode. 
When the [CA] key is pressed, the simulation is terminated.
13
Scanner counter clear
When the [START] key is pressed, the scanner count value is reset to zero and displayed on the 7-
seg display. When the [Interrupt] key is pressed, the machine goes into the sub code input standby 
mode. When the [CA] key is pressed, the simulation is terminated.
14
SPF jam total counter clear
When the [START] key is pressed, the SPF jam total count value is reset to zero and displayed on the 
7-seg display. When the [Interrupt] key is pressed, the machine goes into the sub code input standby 
mode. When the [CA] key is pressed, the simulation is terminated.
15
Scanner mode counter clear
When the [START] key is pressed, the scanner mode count value is reset to zero and displayed on 
the 7-seg display. When the [Interrupt] key is pressed, the machine goes into the sub code input 
standby mode. When the [CA] key is pressed, the simulation is terminated.
25
01
Main motor operation check 
(Cooling fan motor rotation check)
When the [START] key is pressed, the main motor (together with the duplex motor for the duplex 
model) is driven for 30 sec. At that time, to save toner consumption, if the developing until is installed, 
the developing bias, the main charger, and the grid are outputted. Since, in that case, laser discharge 
is required when the motor stops, the polygon motor is driven simultaneously. Check if the 
developing unit is installed or not. If it is not installed, the above high voltage is not outputted and only 
the motor is rotated. After completion of 30 sec operation, the machine goes into the sub code input 
standby mode.
*
This simulation must not be executed by forcibly turning on the door open/close switch. 
10
Polygon motor operation check 
When the [START] key is pressed, the polygon motor is rotated for 30 sec. After completion of 30 sec 
operation, the machine goes into the sub code input standby mode. 
26
02
Size setting
Used to set Enable/Disable of the FC (8.5" x 13") size detection. 
Detection size when a document of the FC ((8.5" x 13") size is used
•For the other destinations, this setting is disabled. 
03
Auditor setting
Used to set the auditor. 
*
When the coin vendor mode is selected, if the auditor setup is ON and the standard tray is
manual feed tray, the standard tray setup must be changed to the main cassette. 
04
Copier duplex setting
When this simulation is executed, the current set duplex code number is displayed. Enter the desired 
code number of duplex setting and press the [START] key, and the entered code number is set. 
*
When this simulation is executed, the binding margin setup is automatically set to the default 
(left side). 
Main 
code
Sub 
code
Contents
Details of operation
Code number
Setting
0
1
FC detection Disable
FC detection Enable
* Default except for the following
* Default only for SCA/Philippines
Unit to 
be used
Destination
Document size
Setting
0 (Disable)
1 (Enable)
Document
SPF
EX Japan AB 
series (FC)
FC (8.5" x 13")
B4
FC (8.5" x 13")
B4
B4
FC (8.5" x 13")
Inch series (FC)
FC (8.5" x 13")
LG (8.5" x 14")
FC (8.5" x 13")
LG (8.5" x 14")
LG (8.5" x 14")
FC (8.5" x 13")
Code number
Mode
0
1
2
Built-in auditor mode
Coin vendor mode
Other
Code number
Mode
0
1
Without duplex
With duplex
* !"#$
AR-M205 SIMULATIONS 7-9
26
05
Count mode setting
When any key input is made, it is displayed on the display section. When the [START] key is pressed, 
the set code data are acquired and stored to the count mode set variable and in the EEPROM, and 
the machine goes into the sub code input standby mode. However, if the [START] key is pressed 
outside the set range, it is not assured. At that time, when the [Interrupt] key is pressed, the data are 
not rewritten and the machine goes into the sub code input standby mode. When the [CA] key is 
pressed, the simulation is terminated without rewriting the data.
06
Destination setting
When this simulation is executed, the current set destination code number is displayed. Enter the 
desired code number of the destination and press the [START] key to set the destination. 
If this setting is changed, SIM46-19 setting is also changed accordingly.
(The paper size is also changed: AB series is changed to A4, and Inch series to Letter.
The AE limit setup is set to the default. 
When the destination is changed (from Japan to EX Japan or from EX Japan to Japan), 
the maintenance cycle is also set to the default accordingly.)
07
Machine condition check (CPM)
When this simulation is executed, the current setting of the machine is displayed. 
18
Toner save mode setting
Used to set ON/OFF of the toner save mode. 
 *
The toner save mode of the user program is also changed accordingly.
30
CE mark conformity control ON/
OFF
When this simulation is executed, the current set code number of CE mark conformity is displayed. 
Enter the desired code number of CE mark conformity and press the [START] key to set the code 
number. 
31
Auditor mode exclusive setup
Used to set whether the manual fed tray can be used or not when the auditor mode is set to the coin 
vendor mode.
*
When this is set to "Exclusive setup ON," if the auditor is set to the coin vendor mode and the
standard tray is set to the manual feed tray, the standard tray must be set to the main cassette. 
36
Cancel of stop at maintenance life 
over
Used to set stop at maintenance life over.
37
Cancel of stop at developer life 
over
When this simulation is executed, the current set code number is displayed. Enter the desired code 
number and press the [START] key to set the code number. The machine goes into the sub code 
input state. 
Main 
code
Sub 
code
Contents
Details of operation
[*1 : Total counter / Developer counter       *2 : maintenance counter]
0:
1:
2:
3:
*1= Double count
*1= Single count
*1= Double count
*1= Single count
*2= Double count
*2 = Double count
*2= Single count
*2= Single count
Code number
Destination
0
1
2
3
4
5
6
Japan AB series
Inch series
EX Japan AB series
EX Japan inch series
EX Japan AB series (FC)
China (EX Japan AB series + China paper support)
Taiwan (EX Japan AB series + China paper support)
7-seg display
Meaning (CPM information)
15
16
20
15CPM
16CPM
20CPM
Code number
Setting
0
1
Toner save OFF
Toner save ON
Code number
Setting
0
1
CE mark conformity control OFF         *Default for 100V system
CE mark conformity control ON
Code number
Setting
0
1
Exclusive setup OFF (Manual paper feed allowed)
Exclusive setup ON (Manual paper fed inhibited)
Code number
Setting
0
1
Stop at maintenance life over
Cancel of stop at maintenance life over * Default
Code number
Setting
0
1
Stop at developer life over 
Cancel of stop at developer life over
+ !"#$