DOWNLOAD Sharp AR-FX11 Service Manual ↓ Size: 4.8 MB | Pages: 84 in PDF or view online for FREE

Model
AR-FX11
Pages
84
Size
4.8 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual for ARFX11
File
ar-fx11.pdf
Date

Sharp AR-FX11 Service Manual ▷ View online

AR-FX11 SIMULATIONS, FAX SOFTWARE SWITCH 6-10
66
2
FAX soft SW initializing
Used to clear the FAX-related soft SW values except for the line signal adjustment value and the machine 
adjustment value and set them to the default values (which differ depending on the country code).
3
FAX PWB memory check
Used to check read/write from/into the memory on the FAX PWB. The check result is displayed for each 
memory.
Main 
code
Sub 
code
Contents
Remark
Sim66-2 SOFT SW
Sim66-2 SOFT SW COUNTRY CODE
OK
Sim66-2 SOFT SW COUNTRY CODE
Sim66-2 SOFT SW COUNTRY CODE
COUNTRY CODE
Japan 00000000
1/26 SELECT UP DN
INITIAL
ARE YOU SURE?  EXEC
Input of a value cannot be made.
OK
INITIAL
EXEC
INITIALIZED
Sim66-2 SOFT SW
COUNTRY CODE
Sweden 10100101
26/26 SELECT UP DN
Simulation code input window
1sec later
CA key
: Simulation cancel
Interrupt key : Sub code input window
OK key
: Settlement
START key : Settlement
C key
: Disable
Return key
: Disable
Selection
Japan
00000000
U.S.A.
10110101
U.K.
10110100
China
00100110
India
01010011
Taiwan
11111110
Australia
00001001
New Zealand 01111110
Singapore
10011100
Malaysia
01101100
Hong Kong
01010000
Middle east
11111101
Germany
00000100
France
00111101
Spain
10100000
Portugal
10001011
Denmark
00110001
Norway
10000010
Switzerland
10100110
Italy
01011001
Belgium
00001111
Luxembourg
01101001
Netherlands
01111011
Finland
00111100
Sweden
10100101
Completion of execution
(Highlighted during execution)
Sim66-3
MEMOR CHK
Sim66-3
MEMOR CHK
OK
Sim66-3
MEMOR CHK
Sim66-3
MEMOR CHK
1:DRAM    4:OPTION
2:SRAM    5:PAGE
3:FLASH   6:MODEM
( 1 - 6 )        
X
DRAM
               EXEC
OK
DRAM
CHECKING MEMORY
EXEC
DRAM
MEMORY CHECK
RESULT
OK
Sim66-3
MEMOR CHK
DRAM
MEMORY CHECK
RESULT
NG XXXXXXXX SUM
Execution normal end
(Highlighted during execution)
SIM66-3 initial window
SIM66-3 initial window
NG
XXXXXXXX SUM
NG
XXXXXXXX A-BUS
NG
XXXXXXXX DATA
NG
XXXXXXXX D-BUS
NG
XXXXXXXX ERASE
NG
XXXXXXXX IO
CA key
: Simulation cancel
Interrupt key : Sub code input window
10-key
: Item selection
OK key
: Settlement and execution of the input value
START key
: Settlement of the input value
Return key
: Returns to the selection window. 
C key
: Disable
*Interruption with C key during execution cannot be made.
Execution error end (Highlighted during execution)
Return
Return
[06]SIMULATIONS ・ FAXSOFTWARESWITCH.fm  10 ページ  2004年11月12日 金曜日 午後2時24分
AR-FX11 SIMULATIONS, FAX SOFTWARE SWITCH 6-11
66
4
Signal send mode
Used to send signals to the line and the machine speaker by setting the signal number. (Signal send is 
continued until interruption is instructed by pressing RETURN key.) The signal send level is selected from 
0db and the soft SW values. Since the level setting is not required for 01 and 31 - 35, the selection menu 
does not appear. The signal send level is returned to the soft SW set value before execution of the mode 
when completing the mode.
6
Print pass code print
Used to print the confidential ID table (confidential box number, confidential box name, confidential pass 
code). Sharp mode confidential information is printed separately.
Main 
code
Sub 
code
Contents
Remark
Sim66-4 SIGNAL OUT
Sim66-4 SIGNAL OUT
Sim66-4 SIGNAL OUT
Sim66-4 SIGNAL OUT
Sim66-4 SIGNAL OUT
SIGNAL SELECT
(1 - 35)
1:NO SIGNAL
2:33600bps(V34)
3:31200bps(V34)
(1 - 35)
XX
After selection with 10-key
OK
33600bps(V34)
1:MAX
2:SOFT SW.
(1 - 2)
X
33600bps(V34)
0dB
EXEC
33600bps(V34)
PRESS BACK TO STOP
EXEC
Sim66-4 SIGNAL OUT
34:DP MAKE
35:DP BREAK
(1 - 35)
XX
OK
After pressing OK key
OK
SIM66-4 initial window
CA key
: Simulation cancel
Interrupt key : Sub code input window
C key
: Input clear
        key
: Page select
10-key
: Number input and item selection
OK key
: Input value settlement and execution
START key
: Input value settlement
RETURN key : Signal send stop
The window is switched with the up and down keys.
Input and switching the window are irrelevant.
Not highlighted with an input of a value.
The window is not switched, either.
When "1: NO SIGNAL" or "31: PSEUDO RNG" - "33: R.B. TONE NONE"
is selected, "0dB" and "SOFT SW" are not selected.
When one of these is selected, the second line is the signal name,
the third and fourth lines are empty, and the fifth line is EXEC display. 
1sec later
Return
Sim66-6
PASS CODE
Sim66-6
PASS CODE
Sim66-6
PASS CODE
PRINT STORED
OK
PRINT CONF.
               EXEC
NO DATA
Sim66-6
PASS CODE
CAN NOT PRINT
OK
OK
1sec later
1sec later
1sec later
CA key
: Simulation cancel
Interrupt key : Sub code input
window
OK key
: Settlement
START key : Settlement
C key
: Disable
Return key
: Disable
[06]SIMULATIONS ・ FAXSOFTWARESWITCH.fm  11 ページ  2004年11月12日 金曜日 午後2時24分
AR-FX11 SIMULATIONS, FAX SOFTWARE SWITCH 6-12
66
7
Image memory content print
Used to print all the image data (confidential receive contents, remote send images, and images which are 
not sent yet) in the image memory of the FAX section. The printed images are remained in the memory after 
printing.
10
Image memory contents clear
Used to clear all the image data (including confidential receive contents) in the image memory of the FAX 
section. The management table is also cleared (initialized) at the same time.
Main 
code
Sub 
code
Contents
Remark
1sec later
1sec later
1sec later
CA key
: Simulation cancel
Interrupt key : Sub code input
window
OK key
: Settlement
START key : Settlement
C key
: Disable
Return key
: Disable
Sim66-7 PRINT MEMORY
Sim66-7 PRINT MEMORY
Sim66-7 PRINT MEMORY
PRINT STORED
OK
PRINT IMAGE MEMORY
               EXEC
NO DATA
Sim66-7 PRINT MEMORY
CAN NOT PRINT
OK
OK
(When there is no image memory)
Sim66-10 IMAGE CLR
OK
Sim66-10 IMAGE CLR
Sim66-10 IMAGE CLR
CLEAR IMAGE MEMORY
ARE YOU SURE? EXEC
CLEAR IMAGE MEMORY
EXEC
CLEARED IMAGE MEM.
DO POWER OFF
Sim66-10 IMAGE CLR
CLEARED
Power source OFF/ON
Simulation code input window
Completion of execution
(Highlighted during execution)
Completion of execution
(Highlighted during execution)
After pressing OK key,
during execution
With prints
Without prints
CA key
: Simulation cancel
Interrupt key : Sub code input
window
OK key
: Settlement
Return key
: Simulation code input window
START key : Settlement
C key
: Disable
Return
[06]SIMULATIONS ・ FAXSOFTWARESWITCH.fm  12 ページ  2004年11月12日 金曜日 午後2時24分
AR-FX11 SIMULATIONS, FAX SOFTWARE SWITCH 6-13
66
11
300bps signal send
Used to send the specified signal at the speed of 300bps by setting the signal number. (Signal send is 
continued until interruption is instructed by pressing RETURN key.) The signal send level is selected from 
0db and soft switch set values. The signal send level is returned to the sot SW set value before execution of 
the mode after completion of the mode.
Main 
code
Sub 
code
Contents
Remark
Sim66-11 300bps SIG.
Sim66-11 300bps SIG.
OK
Sim66-11 300bps SIG.
Sim66-11 300bps SIG.
SIGNAL LEVEL
1:MAX
2:SOFT SW.
( 1 - 2 ) 
X
1:NO SIG.
4:00000
2:11111
5:010101
3:11110
6:00001
( 1 - 6 ) 
X
OK
NO SIGNAL
EXEC
SIM66-11 initial window
CA key
: Simulation cancel
Interrupt key : Sub code input window
C key
: Input clear
      keys
: Page switch
10-key
: Item selection
OK key
: Input value settlement and execution
START key
: Input value settlement
RETURN key : Signal send stop
OUTPUTING SIGNAL
PRESS BACK TO STOP
EXEC
OK
After selection
with 10-key
After selection
with 10-key
After pressing OK key,
during execution
Return
[06]SIMULATIONS ・ FAXSOFTWARESWITCH.fm  13 ページ  2004年11月12日 金曜日 午後2時24分
Page of 84
Display

Click on the first or last page to see other AR-FX11 service manuals if exist.