Sharp AR-C172M (serv.man4) Service Manual ▷ View online
AR-C172M SPECIFICATIONS 3 - 9
C. Reversing single pass feeder
3. Environment conditions
A. Operating environment conditions
B. Transit environment conditions
C. Supply storage environment conditions
D. Standard temperature and humidity
Type
RSPF (Reversing single pass feeder)
Document set
direction
direction
Face up reference
Document
reference
position
reference
position
Center reference
Document paper
feed reference
feed reference
Upper take-up reference (1 to N paper feed
reference)
reference)
Document
transport system
transport system
Sheet through system
Kinds of out-of-
specification
documents
specification
documents
OHP, perforated documents, photograph,
catalogue
catalogue
Document load
capacity
capacity
40 sheets (Thickness 4mm or less.
For 90g/m
For 90g/m
2
, 30 sheets can be set.)
Document
detection Yes/No
detection Yes/No
Yes (Size detection on the document tray,
traveling detection)
traveling detection)
Detection size
AB-1/
AB-3
AB-3
A3, B4, A4, A4R, B5, B5R, A5
AB-2
A3, 216 x 330, A4, A4R, B5, B5R,
A5
A5
Inch-1
11" x 17", 8.5" x 14", 8.5" x 11",
8.5" x 11"R, 8.5" x 5.5"
8.5" x 11"R, 8.5" x 5.5"
Inch-2
11" x 17", 8.5" x 13", 8.5" x 11",
8.5" x 11"R, 8.5" x 5.5"
8.5" x 11"R, 8.5" x 5.5"
Selection between 8.5" x 13" and 8.5" x 14"
can be made by the user setting.
can be made by the user setting.
Document
inversion
inversion
Yes (However, 8.5" x 5.5" is inhibited.)
Document weight
56 to 90g/m
2
(15 to 24 lbs.)
Stream feeding
mode
mode
Yes (Standby 5 sec)
Mixed-load
documents
documents
Mixed-load paper feed: Inhibited
Random paper feed: Inhibited
Random paper feed: Inhibited
Document tray
guide display
guide display
A3/A4, 11, B4/B5, 8.5, A4R/A5, B5R, A5R,
5.5
5.5
Power supply
From main unit (26.4 W)
Dimensions
(W x D x H) 583 x 435 x 133 mm
Weight
Approx. 5.4 kg
Temperature
20 to 25°C (68 to 77°F)
Humidity
65 ±5%
˚
˚
˚
˚
Humidity
RH
Temperature
˚
˚
˚
˚
Humidity
RH
Temperature
–5˚
˚
Temperature
Humidity
RH
AR-C172M CONSUMABLE PARTS 4 - 1
[4] CONSUMABLE PARTS
1. Supply system table
A. European Subsidiary
2. Consumables (kit, unit)
*1: Replace at 100K or within 2 years
No.
Item
Model Name
Content
Life
Commonality with
other host machines
Remarks
1
Toner Cartridge
(Black)
(Black)
AR-C26TBN
Toner Cartridge (Black) with IC Chip
(Toner ; Net 525g)
(Toner ; Net 525g)
x 1
16.7k
Common
(AR-C170)
(AR-C262)
(AR-C262)
* Life : A4 size
at Area
Coverage 6%
Coverage 6%
2
Toner Cartridge
(Cyan)
(Cyan)
AR-C26TCE
Toner Cartridge (Cyan) with IC Chip
(Toner ; Net 315g)
(Toner ; Net 315g)
x 1
11k
Common
(AR-C260)
(AR-C170)
(AR-C262)
(AR-C170)
(AR-C262)
* Life : A4 size
at Area
Coverage 5%
Coverage 5%
3
Toner Cartridge
(Magenta)
(Magenta)
AR-C26TME Toner Cartridge (Magenta) with IC Chip
(Toner ; Net 315g)
x 1
11k
Common
(AR-C260)
(AR-C170)
(AR-C262)
(AR-C170)
(AR-C262)
* Life : A4 size
at Area
Coverage 5%
Coverage 5%
4
Toner Cartridge
(Yellow)
(Yellow)
AR-C26TYE
Toner Cartridge (Yellow) with IC Chip
(Toner ; Net 315g)
(Toner ; Net 315g)
x 1
11k
Common
(AR-C260)
(AR-C170)
(AR-C262)
(AR-C170)
(AR-C262)
* Life : A4 size
at Area
Coverage 5%
Coverage 5%
5
Drum Cartridge
AR-C26DUN Drum Cartridge
(Drum/Unit Parts included)
x 1
50k
Common
(AR-C170)
(AR-C262)
(AR-C262)
Color identification seal (C/M/Y/Bk)
x 1 each
6
Drum
AR-C26DMN OPC Drum
x 1
50k
Common
(AR-C170)
(AR-C262)
(AR-C262)
7
Main Charger Kit
AR-C26MKE Charger Unit
x 1
50k
Common
(AR-C260)
(AR-C170)
(AR-C262)
(AR-C170)
(AR-C262)
Cleaning Blade
x 1
Toner Receiving Seal
x 1
Part name
Model name
Content
Life
1
Upper heat roller kit
AR-C26UH
Upper heat roller
x 1
100K *1
Heat roller 60T gear
x 1
Upper heat roller bearing
x 2
Thermistor
x 1
Upper heat roller stopper
x 2
2
Lower heat roller kit
AR-C26LH
Lower heat roller
x 1
100K *1
Lower heat roller bearing
x 2
Thermistor
x 1
Lower heat roller stopper
x 2
Fusing separation pawl lower
x 2
3
Transfer belt kit
AR-C26TT
Transfer belt
x 1
100K *1
4
Transfer roller kit
AR-C26TX
Transfer roller
x 4
100K
5
Transfer waste toner tank unit
AR-C26HB
Transfer waste toner tank unit
x 1
100K
6
Filter kit
AR-C26FL
Ozone filter A
x 1
50K
Ozone filter B
x 1
7
Saddle staple cartridge
AR-SC2
—
5
Fusing unit
AR-C26FU (230V heater lamp)
AR-C26FU1 (120V heater lamp)
AR-C26FU2 (100V heater lamp)
AR-C26FU2 (100V heater lamp)
Fusing unit for servicing
(including upper/lower heater lamps)
(including upper/lower heater lamps)
*1
6
Transfer belt unit
AR-C26TU
Transfer unit for servicing
100K *1
AR-C172M CONSUMABLE PARTS 4 - 2
3. Photoconductor cartridge, toner cartridge
A. Lot number identification and the term of validity
(1) Photoconductor
The term of validity: 36 months from the production day (month).
(2) Photoconductor cartridge
The term of validity: 36 months from the production day (month).
(3) Toner cartridge
The term of validity: 24 months from the production day (month).
(1)
Alphabet
Indicates the model support code.
Indicates the model support code.
(2)
Figure
Indicates the end digit of the packing year.
Indicates the end digit of the packing year.
(3)
Figure or X, Y, Z
Indicates the packing month. (X= October, Y= November,
Z= December)
Indicates the packing month. (X= October, Y= November,
Z= December)
(4) (5) Figure
Indicates the packing day.
(6)
Alphabet
Indicates the production division.
Indicates the production division.
(1)
Figure
Version No.
Version No.
(2)
Figure
The end digit of the year.
The end digit of the year.
(3)
Alphabet
Production code (B for SOCC)
Production code (B for SOCC)
(4)
Alphabet
Destination code
Destination code
(5) (6) Figure
Production day
(7)
Figure or X, Y, Z
Indicates the production month. (X= October, Y= November,
Z= December)
Indicates the production month. (X= October, Y= November,
Z= December)
(1)
Alphabet or figure
Unit code
Unit code
(2)
Alphabet
Destination code
Destination code
(3)
Alphabet
Skating
Skating
(4)
Alphabet
Production site code
Production site code
(5)
Figure
Serial number (5 digits)
Serial number (5 digits)
(6)
Figure
Production year, month, day (6 digits)
Production year, month, day (6 digits)
(7)
Alphabet
Version No. (A ~ sequentially revised)
Version No. (A ~ sequentially revised)
(1)
(2)
(3)
(4)
(5)
(6)
(1) (2) (3) (4) (5) (6) (7)
(1)
(4)
(5)
(6)
(7)
(2)
(3)
AR-C172M UNPACKING AND INSTALLATION 5 - 1
[5] UNPACKING AND INSTALLATION
1. Installing (use) conditions
Before installing the machine, check that the following installing
(use) conditions are satisfied.
(use) conditions are satisfied.
If the installing (use) conditions are not satisfied, the machine may
not display full performances, resulting in troubles. It may also
cause safety problems. Therefore, be sure to arrange the installing
(use) conditions before setting up the machine.
not display full performances, resulting in troubles. It may also
cause safety problems. Therefore, be sure to arrange the installing
(use) conditions before setting up the machine.
A. Bringing space
For installation of a large size machine, be sure to check that the
door size is great enough before bringing in.
door size is great enough before bringing in.
B. Installing space
The following space must be provided around the machine in
order to assure machine performances and proper operations.
order to assure machine performances and proper operations.
If any option is installed, provide the additional space for installing
it.
it.
Especially the space at the rear of the machine must be provided
sufficiently. If not, the machine cannot exhibit functions against
heat and dust, causing some troubles.
sufficiently. If not, the machine cannot exhibit functions against
heat and dust, causing some troubles.
C. Power source
(Capacity, voltage, frequency, safety, plug)
If the power specifications are not satisfied, the machine cannot
exhibit full performances and may cause safety trouble.
exhibit full performances and may cause safety trouble.
Strictly observe the following specifications.
(1) Power capacity
Check that the following power capacity is satisfied. If not, addi-
tionally provide a power source.
tionally provide a power source.
Current capacity
100V: 15A or more
200V: 10A or more
(2) Power voltage
Measure the voltage during copying to check that the voltage is in
the range of the specified voltage ±10%.
the range of the specified voltage ±10%.
If the voltage is outside the specified range, use thicker lead wires
to reduce impedance.
to reduce impedance.
(An electrical work is required.)
Use of a step-up transformer is also available. In this case, the
capacity must be great enough for the max. power consumption of
the machine.
capacity must be great enough for the max. power consumption of
the machine.
(3) Power frequency, waveform
The frequency must be within the range of the specified frequency
±2%. If power waveform is deformed, a trouble may occur.
±2%. If power waveform is deformed, a trouble may occur.
(4) Safety
Be sure to properly ground the machine.
(5) Power plug
Check the form of the power plug. If the shape does not match, do
not use it.
not use it.
D. Floor strength and level
This machine is considerably heavy and becomes heavier with an
option installed.
option installed.
The floor must be strong enough for assuring safety.
If not, color shift or image distortion may occur.
E. Direct rays of the sun, dust, temperature,
humidity, gasses, chemicals, vibration
(1) Temperature and humidity
This machine is designed to perform properly under the specified
temperature and humidity. If the temperature and humidity
exceeds the specified range, the machine may not operate prop-
erly and or cause equipment failure.
temperature and humidity. If the temperature and humidity
exceeds the specified range, the machine may not operate prop-
erly and or cause equipment failure.
Especially when the humidity is too high, paper absorbs humidity
to cause a paper jam or dirty copy.
to cause a paper jam or dirty copy.
(Do not install the machine near a stove, a humidifier, or an air
conditioner.)
conditioner.)
Do not install the machine near a heater, a cooler, or a humidifier.
Dew may be formed inside the machine to cause a trouble. Use
enough care for ventilation.
enough care for ventilation.
No.
Content
1
Bringing space
2
Installing space
3
Power source (Capacity, fluctuation, safety)
4
Floor strength
5
Direct rays of the sun, dust, temperature, humidity,
gases, chemicals
gases, chemicals
80 cm
(31.5")
(31.5")
30cm
(11.8")
(11.8")
60cm
(23.6")
(23.6")
60cm
(23.6")
(23.6")
Humidity (RH)
80%
60%
20%
15˚C
30˚C
35˚C
Temperature
Click on the first or last page to see other AR-C172M (serv.man4) service manuals if exist.