DOWNLOAD Sharp AR-405 (serv.man10) Service Manual ↓ Size: 924.36 KB | Pages: 85 in PDF or view online for FREE

Model
AR-405 (serv.man10)
Pages
85
Size
924.36 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / AR405 Service Manual-Simulation Codes
File
ar-405-sm10.pdf
Date

Sharp AR-405 (serv.man10) Service Manual ▷ View online

Note
26 - 30
Purpose
Setting
Function
(Purpose)
Used to set the CE mark conforming operation mode. (For flickers when driving the fusing heater lamp.)
Section
Item
Specifications
Operation mode (Common)
Operation/
Procedure
Enter the number corresponding to the operation mode with the 10-key and press the [OK] key.
Set value 
Content 
0
CE mark control inhibit 
1
CE mark control allowed (Default)
0 : Normal operation heater lamp slow up control
1 : CE mark standard complying operation (Heater lamp slow up control) (Europe)
Note
26 - 35
Purpose
Setting
Function
(Purpose)
Used to set whether the trouble history display of SIM 22-4 is displayed as one trouble or as the number of
continuous troubles when two or more troubles of a same kind occured.
Section
Item
Specifications
Operation/
Procedure
Used to set whether the trouble history display by SIM 22-4 is displayed as one trouble or as the accumulated
number of continuous troubles when two or more troubles of same kind occur continuously.
Select the number corresponding to the display mode with the 10-key and press the [OK] key.
1 : The trouble history display by SIM 22-4 is displayed as it is when two or more troubles occur continuously.
0 : The trouble history display by SIM 22-4 is displayed as one trouble when two or more troubles occur continuously.
Default: 0
Note
AR-405
1/21/1999
8 – 42
26 - 36
Purpose
Setting
Function
(Purpose)
Used to set the ICU fan operating temperature. (Operation in pre-heat mode.) (Excluding Japan models.)
Section
ICU
Item
Operation
Operation/
Procedure
Used to set the threshold value of the ambient temperature for turning ON the ICU fan motor in the pre-heat
mode.
Set range:
0~33[˚C]
Default:
30[˚C] (30)
Enter the operating temperature with the 10-key pad and press the [OK] key.
Note
26 - 41
Purpose
Setting
Function
(Purpose)
Used to enable/disable the auto magnification ratio select (AMS) function in the pamphlet copy mode.
Section
Item
Specifications
Operation mode (Common)
Operation/
Procedure
Note
26 - 44
Purpose
Setting
Function
(Purpose)
Used to set the model of the unit which is connected to the SCSI I/F of ICU PWB.
Section
ICU
Item
Specifications
Interface/Communication
Operation/
Procedure
A is at the left of B when viewed from the rear side.
  0: No connection
  1: Printer controller
  3: External printer controller (Not used)
  4: Scanner controller (Not used)
  8: (Not used)
One SCSI channel available
Two SCSI channels available
Note
AR-405
8 – 43
1/21/1999
27
27 - 1
Purpose
Setting
Function
(Purpose)
Used to set the operation  specifications when a communication trouble occurs between the host computer  and
MODEM (on the copier). (When a communication trouble occurs between the host computer and MODEM
(copier), the self diag display (U7-00) is printed and setting is made to select inhibit/allow of printing.)
Section
Communication unit (TEL/LIU/MODEM etc.)
Item
Specifications
Operation mode (Common)
Operation/
Procedure
Enter the code number corresponding to the operation mode with the 10-key and press the [OK] key.
Used to set Enable/Disable of U7-01 trouble detection.
Set value
Content
0
U7-01 trouble detection is disabled. (Default)
1
U7-01 trouble detection is enabled.
0: Though a communication trouble occurs between the host computer and the MODEM (machine side), the operation
of the machine is not affected.
1: When a communication trouble occurs between the host computer and the MODEM (copier side), the self diag
display (U7-00) id shown and printing is inhibited.
Note
27 - 2
Purpose
Setting
Function
(Purpose)
Used to set and change the host computer/MODEM numbers. (This setting is required when a communication is
made between the copier and a computer through MODEM.)
Section
Communication unit (TEL/LIU/MODEM etc.)
Item
Data
User data
Operation/
Procedure
1. Select the PC/MODEM(HOST#/TEL#)to be set or changed. ’The selected key is highlighted.)
2. Press the [OK] key.
The key is highlighted and inquiring of the present set number of the selected PC/MODEM is made to the host
computer.
(When the number is supplied from the host normally.)
The present set number is displayed in the column of "PRESENT"PRESENT (or no display is made if not registered)
and the [OK] key at the upper right returns from the gray display to the normal display.
(In case of a trouble)
"Failed (U7-00)" is displayed in the column of PRESENT and the OK key at the lower right returns from the highlight
display to the normal display.
3. When changing the number, enter the new number (max. 24 digits) with the 10-key and the following keys.
#: [P]((program) key
* : [AUDIT CLEAR] ((Dept. count end) key
, : [ i ]((Information) key
4. When the [OK] key at the upper right is pressed, the newly set number for the selected PC/MODEM is registered.
(When registered normally)
The number displayed in the column of NEW disappears and the newly set number appears in the column of
PRESENT
(In case of a trouble)
"Failed (U7-00)" is displayed in the column of NEW.
AR-405
1/21/1999
8 – 44
Note
For this setting, the copier and the host computer must be connected with a communication line (MODEM).
27 - 3
Purpose
Setting
Function
(Purpose)
Used to set and change the ID numbers of the copier and the host computer/MODEM numbers. (This setting is
required when a communication is made between the copier and a computer through MODEM.)
Section
Communication unit (TEL/LIU/MODEM etc.)
Item
Data
User data
Operation/
Procedure
1. Select between PPC(copier) and PC/MODEM(host).
The key is highlighted.
2. Press the [OK] key at the lower right. (The key is highlighted and an inquiry of the selected ID No, to the host.)
(When the number is supplied from the host normally)
 The present set number is displayed in the column of PRESENT (or no display is made if not registered) and the [OK]
key at the upper right returns from the gray display to the normal display.
(In case of a trouble)
"Failed (U7-00)" is displayed in the column of PRESENT and the OK key at the lower right returns from the highlight
display to the normal display.
3. When changing the number, enter the new number (max. 24 digits) with the 10-key and the following keys.
X: [P](program) key
Y: [AUDIT CLEAR](dept. count end) key
The entered number is displayed in the column of "NEW"
4. When the [OK] key at the upper right is pressed, the newly set ID number of the selected PC/MODEM is registered on
the host side.
(When registered normally)
The number in the column of NEW disappears and the newly set and registered number appears in the column of
PRESENT.
(In case of a trouble)
"Failed (U7-00) " is displayed in the column of NEW
Note
For this setting, the copier and the host computer must be connected with a communication line (MODEM).
AR-405
8 – 45
1/21/1999
Page of 85
Display