DOWNLOAD Sharp AR-405 (serv.man10) Service Manual ↓ Size: 924.36 KB | Pages: 85 in PDF or view online for FREE

Model
AR-405 (serv.man10)
Pages
85
Size
924.36 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / AR405 Service Manual-Simulation Codes
File
ar-405-sm10.pdf
Date

Sharp AR-405 (serv.man10) Service Manual ▷ View online

Note
24 - 5
Purpose
Data clear
Function
(Purpose)
Used to reset the developer counter. (The developer counter of the DV unit which is installed is reset.)
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Developer/Toner Hopper
Item
Counter
Developer
Operation/
Procedure
1. Press the [EXECUTE] key.
The display for reconfirmation to clear is shown.
2. Select YES or NO to clear the counter.
YES : Clear
NO : Not clear
The above counter is cleared after replacement of developer.
Note
24 - 6
Purpose
Data clear
Function
(Purpose)
Used to reset the copy counter.
Section
Item
Counter
Copier
Operation/
Procedure
1. Press the [EXECUTE] key.
The display for reconfirmation to clear is shown.
2. Select YES or NO to clear the counter.
YES : Clear
NO : Not clear
Generally, the counter is not cleared.
Note
AR-405
1/21/1999
8 – 34
24 - 7
Purpose
Data clear
Function
(Purpose)
Used to clear the OPC drum (membrane decrease) correction counter. 
(This simulation is executed when the OPC drum is replaced.
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Photo conductor
Item
Counter
Photo conductor
Operation/
Procedure
1. Press the [EXECUTE] key.
The display for reconfirmation to clear is shown.
2. Select YES or NO to clear the counter.
YES : Clear
NO : Not clear
The above counter is cleared after replacement of the OPC drum.
Note
24 - 8
Purpose
Data clear
Function
(Purpose)
Used to clear the Zaurus print counter.
Section
Item
Counter
Operation/
Procedure
1. Press the [EXECUTE] key.
The display for reconfirmation to clear is shown.
2. Select YES (Clear) or NO (Not clear).
YES : Clear
NO : Not clear
Generally the counter is not cleared. 
Note
Japan only
24 - 9
Purpose
Data clear
Function
(Purpose)
Used to clear the printer print counter. (The counter is cleared after completion of maintenance.)
Section
Printer
Item
Counter
Printer
AR-405
8 – 35
1/21/1999
Operation/
Procedure
1. Select the counter to be cleared.
PRINTER : Printer counter
OTHER
:  The other counters
(When selected, it is highlighted.)
2. Press the [EXECUTE] key.
The display for reconfirmation to clear is shown.
3. Select YES (Clear) or NO (Not clear).
YES : Clear
NO : Not clear
The above counter is cleared after completion of maintenance.
Note
24 - 10
Purpose
Data clear
Function
(Purpose)
Used to clear the FAX counter. (The counter is cleared after completion of maintenance.) (FAX model only)
Section
FAX
Item
Counter
Operation/
Procedure
1. Select the counter to be cleared.
   SEND FAX
: FAXSend counter
    RECEIVE FAX :  FAXReceive counter
(When selected, it is highlighted.)
2. Press the [EXECUTE] key.
The display for reconfirmation to clear is shown
3. Select YES or NO to clear the counter.
YES : Clear
NO : Not clear
After completion of maintenance, the above counter is cleared.
Note
25
25 - 1
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the main drive (excluding the scanner section) amd to check the operation of the
toner concentration sensor. (The toner concentration sensor output can be monitored.)
Section
DRIVE
Item
Operation
AR-405
1/21/1999
8 – 36
Operation/
Procedure
The main motor rotates for 3 minutes, and the drive system can be checked.
The toner concentration sensor output value is displayed.
When the [EXECUTE] key is pressed, it is highlighted and the main motor rotates and the toner concentration
sensor output value is displayed.
After 3 minutes, the main motor stops and the [EXECUTE] key returns to the normal display.
If the [EXECUTE] key is pressed during rotation, the operation is stopped and the [EXECUTE] key returns to the
normal display.
Note
25 - 2
Purpose
Setting
Function
(Purpose)
Used to make the initial setting of toner concentration when replacing developer.
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Developer/Toner Hopper
Item
Operation/
Procedure
When the [EXECUTE] key is pressed, it is highlighted and the main motor rotates, and the toner concentration
sensor detects the toner concentration and the output value is displayed.
After stirring for 3 minutes, the toner concentration detection level average value is set (stored) as the reference
toner concentration control value.
If the [EXECUTE] key is pressed during rotation, the operation stops and the [EXECUTE] key returns to the
normal display.
If [EE-EU] or [EE-EL] is displayed, it means the reference toner concentration control value is not set normally.
Default: 0
(Note) Do not set to 0.
Note
26
26 - 1
Purpose
Setting
Function
(Purpose)
Used to set options. (This simulation is used to make option setting when an option is installed.)
Section
Item
Specifications
Options
AR-405
8 – 37
1/21/1999
Page of 85
Display

Click on the first or last page to see other AR-405 (serv.man10) service manuals if exist.