Sharp AR-285 (serv.man12) Service Manual ▷ View online

41 - 3
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the document size sensor and the related circuit. (The document size sensor
output level can be monitored with the LCD.)
Section
Others
Item
Operation
Operation/
Procedure
The detection output level of each sensor is displayed in real time.
OCSW
Document cover state
PD*
Document sensor
 The value in [ ] shown at the right of each sensor name is the threshold value.
Note
43
43 - 1
Purpose
Setting
Function
(Purpose)
Used to set the fusing temperature in each operation mode.
Section
Fixing (Fusing)
Item
Operation
Operation/
Procedure
1. Select the kind of lamps and the operation mode with [
], [
] keys.
2. Enter the set value with the 10-key.
3. Press the [OK] key to set the fusing temperature set in procedure 2.
Used to set the fusing temperature in the normal mode and in the power save mode.
INSIDE NORMAL:
The control temperature in the normal mode and when the center lamp is heated. (190)
OUTSIDE NORMAL:
The control temperature in the power save mode (pre-heat mode) and the side lamps are heated.
(190)
INSIDE PREHEAT:
The control temperature in the manual copy mode when the center lamp is heated. (*1)
OUTSIDE PREHEAT: The control temperature in the manual copy mode when the side lamps are heated. (*2)
INSIDE MFT:
The control temperature in the manual copy mode when the center lamp is heated. (200)
OUTSIDE MFT:
The control temperature in the manual copy mode when the side lamps are heated. (200)
(  ): Default
8 – 83
Model/Destination
Set value
*1
*2
Japan
130
130
AR-335
130
130
AR-280/285 (100V series)
125
125
AR-280/285 (200V series)
110
110
Note
Be sure to set to the default value. If not, a trouble may occur.
44
44 - 1
Purpose
Setting
Function
(Purpose)
Used to set whether the correction functions of the image forming (process) section are valid or not.
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Item
Operation
Operation/
Procedure
Enter the code number corresponding to each correction operation with the 10-key and press the OK key.
To enable all the correction functions, set to 3.
(Note) The default setting must be 3.
Set value
Developing bias voltage
correction limit
OPC drum sensitivity
correction
0
Disable
Disable
1
Disable
Enable
2
Enable
Disable
3
Enable
Enable
Note
(Note) It must be set to the default 3.
8 – 84
44 - 2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the sensitivity (gain) of the OPC drum mark sensor and the image density sensor.
Section
Image process
(Photoconductor/Developping/Transfer/Cleaning)
Photo conductor
Item
Operation
Operation/
Procedure
When the [EXECUTE] key is pressed, it is highlighted and the main motor rotates to start the drum marking
sensor and the image density sensor gain adjustment. (The adjustment is automatically performed.)
After completion of the adjustment, the [EXECUTE] key returns to the normal display and the main motor stops.
At that time, the gain level of each sensor is displayed.
If the adjustment is not completed properly, the ERROR display is shown.
DMLED: Drum marking sensor gain adjustment value
PCLED: Image density sensor gain adjustment value
Note
44 - 4
Purpose
Setting
Function
(Purpose)
Used to set the target image (reference) density level in the developing bias voltage correction.
(for OPC drum type B)
Section
Image process
(Photoconductor/Developping/Transfer/Cleaning)
Item
Data
Adjust/Setting data
Operation/
Procedure
1. Enter the set value (38) with the 10-key.
2. Press the [OK] key. (The value entered in procedure 1 is set.)
Set value: 38
Note
It must be set to 38.
8 – 85
44 - 5
Purpose
Setting
Function
(Purpose)
Used to set various parameters (main charger grid voltage, laser beam power, correction start developing bias
voltage) in developing bias correction.
(for OPC drum type B)
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Item
Operation
Operation/
Procedure
1. Select the parameter mode with [
], [
] keys.
2. Enter the parameter with the 10-key.
3. Press the [OK] key. (The value entered in procedure 2 is set.)
GRID BIAS VOL:
Reference charging voltage level in patch forming (380) (Set value)
DEVE BIAS VOL : Reference developing bias voltage level in patch forming (210) (Set value)
LASER DUTY:
Laser duty level in patch forming (255)
Note
Be sure to set to the specified value. If not, the print image density may be disturbed.
44 - 9
Purpose
Operation data output/Check (Display/Print)
Function
(Purpose)
Used to check the data on the result of the image forming section correction (process correction) (the corrected
main charger grid voltage in each print mode, developing bias voltage, the laser power, etc.)
(This simulation allows to check whether the correction is executed properly or not.)
Section
Image process
(Photoconductor/Developping/Transfer/Cleaning)
Item
Data
Operation data (Machine condition)
Operation/
Procedure
Used to display the drum rotating time and the high voltage output in each copy mode and the laser power
correction power.
DRUM ROTATION:
Drum rotating time (sec)
DEVE RFERENCE ADJUST: Toner concentration correction amount
DRUM:
Drum identification result (1: Type A   2: Type B   C: Others)
GR_BS:
Main charger grid voltage level (*1)
DV_BS:
Developing bias voltage level (*1)
           ((Display) *1 : Sim 8-1, 8-2 Set voltage/actual output voltage (including corrected amount)
LD_AD:
Laser power correction power display (mW)
AUTO:
Auto mode
CHARA:
Character mode
CHARA_P: Character/photo mode
PHOTO:
Photo mode
PRT:
Printer mode
FAX:
Fax mode (Japan only)
8 – 86