Sharp AR-285 (serv.man12) Service Manual ▷ View online

26 - 2
Purpose
Setting
Function
(Purpose)
1) Used to set the paper size of the large quantity paper tray. (When the paper size is changed, the lift paper size must
be also changed with this simulation.) 
2) Used to detect the paper or document size of 8.5" x 13" (Inch series) and set the display mode. (All paper feed modes)
Section
Paper transport
Item
Specifications
Operation/
Procedure
1. Select the item to be set with [
] key and [
] key.
A: Large capacity paper tray paper size setting
B: 8.5" x 13" (330mm/13") paper size detection mode setting
2. Enter the code number corresponding to the paper size of the large capacity paper feed tray with the 10-key and press
the [OK] key. 
Set value 
Setting size 
1
8.5
11
2
A4 (Default)
3
B5
2’. Used to set the size detection mode when 8.5" x 13" paper or document is used.
Enter the code number with the 10-key pad and press the [OK] key.
 Detection size when 8.5" x 13" document/paper is used
Unit
Destination
Set value
 0 
 (Default)
(Invalid)   
1
(Valid)
Document
AR-SP1
All destinations
8.5" x 14"
8.5" x 13"
*1
AR-AF1
AR-RF1
Japan
A4R
A4R
*5
EX AB series  (SLK/SEEG)
A4R
A4R
*5
EX AB series  (SCA/Others)
A4R
8.5"  x  13"
*3
Inch series (SEC/SECL)
8.5" x 14"
8.5" x 14"
*5
Inch series (Others)
8.5" x 14"
8.5" x 13"
*1
Document table
Japan/EX AB series
B4
8.5" x 13"
*2
Inch series
8.5" x 14"
8.5" x 13"
*1
Paper
Main body
Manual feed tray
All destinations
8.5" x 14"
8.5" x 13"
*4
Paper feed cassette All destinations
        —      *6
AR-DE1/DE2
All destinations
AR-LC1
All destinations
*1: A document of 8.5" x 14" is detected as 8.5" x 13".
*2: A document of B4 is detected as 8.5" x 13".
*3: A document of A4R is detected as 8.5" x 13".
*4: A document of 8.5" x 14" is detected as 8.5" x 13".
*5: Applicable by replacing the document set tray of the AR-AF1/RF1.
*6: Setting is available with the key operator program (P40).
Note
8 – 67
26 - 3
Purpose
Setting
Function
(Purpose)
Used to set the specifications of the auditor. Setting must be made depending on the use condition of the auditor.
Section
Auditor
Item
Specifications
Operation/
Procedure
Enter the code number corresponding to the auditor specification mode with the 10-key pad and press the [OK]
key.
Set value 
Specification mode 
1
Built-in auditor mode (Default)
2
Coin vendor 
3
Others 
Note
26 - 5
Purpose
Setting
Function
(Purpose)
Used to set the count mode of the total counter and the maintenance counter.
Section
Item
Specifications
Counter
Operation/
Procedure
Used to set the single count-up or double count-up for the total counter, the maintenance counter, and the
developer counter when printing is performed with A3, 11 x 17" paper,
1. Select the kind of the counter with [
] and [
] key.
A
Total
B
Maintenance
C
Developer
2. Enter "1" or "2" with the 10-key pad and press the [OK] key.
1 : Single count
2 : Double count
Default: 2
Note
8 – 68
26 - 6
Purpose
Setting
Function
(Purpose)
Used to set the specifications depending on the destination.
Section
Item
Specifications
Destination
Operation/
Procedure
Select the destination referring to the table below.
U.S.A.
United States of America
Canada
Canada
Inch
Inch series, other destinations
Japan
Japan
AB_B
AB series (B5 detection) other destinations
Europe
Europe
U.K.
United Kingdom
Aus.
Austrailia
AB_A
AB series (A5 detection) other destinations
When the destination setting is changed, the following specification is changed.
(Toner save mode setup specification) (Paper specification)
Note
8 – 69
26 - 15
Purpose
Setting
Function
(Purpose)
Used to set the fusing operation mode (paper curl corresponding mode).
Section
Fixing (Fusing)
Item
Operation
Operation/
Procedure
Due to the paper type (paper property), paper may be curled in the fusing section to cause a paper jam. To
prevent against this, the fusing conditions is changed.
Enter the code number corresponding to the fusing condition and press the [OK] key. 
Set value 
Remedy mod
Fusing condition
0
Normal operation 
(Default)
1
Remedy mode 1
a. Racing until the specified fusing temperature is reached.
2
Remedy mode 1
a. Racing is performed until the specified fusing temperature is reached.
b. Copy mode is duplex mode or sort.
Group mode 
  Previous rotation is made for 5 sec before starting copying.
Note
26 - 18
Purpose
Setting
Function
(Purpose)
Used to set VALID/INVALID of toner save operation. (This simulation is valid only in the Japan and UK versions.
(It depends on SIM 26-6 (Destination setting). For the other destinations, the same setting can be executed with
theuser program..)
Section
Item
Specifications
Operation mode (Common)
Operation/
Procedure
Enter the code number corresponding to the condition (the toner save YES/NO) with the 10-key and press the
[OK] key.
Set value 
Toner save 
0
YES 
1
NO (Default)
Note
8 – 70
Page of 118